Instruction/ maintenance manual of the product PMCS 6.15 GE
Go to page of 24
GE MULTILIN TM EnerVista PMCS 6.15 Quick Start Guide i.
EnerVista PMCS 6. 15 Quick Start Guide Table Of Contents INTRODUCTION ............................................................................................................................................. 3 SYSTEM REQUIREMENTS .................
Introduction Welcome to the Enervista P MCS 6.15 Quick start Guide . The intent of this g uide is to quickly walk a user through the basic configuration and opera tion steps in order to view data fr om a GE Multilin device.
EnerVista PMCS 6. 15 Quick Start Guide Recommended system requirements : 2+ GHz Processor 1GB RAM Video capable of displaying 16-bit, 1280x1024 resolution IEDs Supported - Summary The following devices are supported in the Modbus Servers in this release.
Supported Firmware Versions IED Product Versions Supported IED Product Versions Supported 239 2.3x to 2.7x Spectra MicroVersa Trip 5.1x 269+ 6.0x Enhanced MicroVersa Trip C 4.1x 369 1.6x to 2.3x Enhanced MicroVersa Trip D 4.1x 469 2.5x to 5.0x EPM1000 3.
EnerVista PMCS 6. 15 Quick Start Guide Introduction to EnerVista PMCS 6.15 Welcome to EnerVista PMCS 6.15, a PC-ba sed program for on-de mand monitoring a nd control. After successful installation of P MCS 6.15, the first item to launch is the EnerVista P MCS 6.
DEVICE SETUP Toolkit group - Device Setup Introduction to Device Setup The Device Setup tool is use d to add/edit/modify GE IEDs. The ma ximum number of devices t hat can be configured is 100.
EnerVista PMCS 6. 15 Quick Start Guide “Serial” – reserved for devic es using Modbus RT U accessed via PC COM ports connected t o a RS232/485 line.
FAQ Device Modbus slave addressing considerations when using a Multinet or Modbus Bridge: Modbus RTU devices configured with a Multilin Multinet are configured in the Ethernet Site. Each device will have the same IP Address (that of the Multinet) and Modbus Port, but each device on the same Multinet must have a unique Modbus address.
EnerVista PMCS 6. 15 Quick Start Guide Serial, Modbus RTU parameters Returning to the Main Menu: Should you want t o cancel your changes made in this s ession, you can click on the [CANCEL] bu tton to exit back to the EnerVista PMCS Configurator me nu without savi ng.
FAQ EVENTS The Enervista Event Logging syste m is made up of tw o components: the Even tServer, which collects events and stores them in an on-line database, and the EventView er, which provides an intuitive graphical interface for viewing, querying, and PMCS the database c ontents.
EnerVista PMCS 6. 15 Quick Start Guide What’s on the EventViewer Screen? To launch the EventViewer select the “EV ENTS” catego r y i n T O O L K I T a r e a o f t h e m a i n w i n d o w .
FAQ WAVEFORMS Toolkit group – Waveforms Waveform Availability Waveforms are only av ailable from devices that support and are confi gured for automatic wave form retrieval. Manual triggering of waveforms is supported t hrough Waveform Client ap plication on some of the Supported devices.
EnerVista PMCS 6. 15 Quick Start Guide On clicking [Viewer] , Waveform Viewe r application will be launched, which has wave form display, harmonic display, phasors display, a nd playback features. Waveform files retrie ved by Waveform Server in COMTREADE format can be view ed in the Waveform Clien t.
FAQ Displayed on the top of the window are the following parameter fields: • The Blue field (labeled ) displays the parameter value at the blue cursor 2 position. • The Green field (labeled ) displays the parameter valu e at the green cursor 1 p osition.
EnerVista PMCS 6. 15 Quick Start Guide • Select the Trigger button to have the cursor times displayed as an offset from the ‘Trigger Time’ of the COMTRADE fil e. A negative time i ndicates a time that occurs be fore the trigger and a positive time indicates a time that occurs after the trigger.
FAQ • The Delta box on the t op right side of the s creen indicates the differe nce in magnitude between the two cursors. The box at the top shows the di fference in time (milliseconds). • Waveforms may be super-i mposed on top of each other by selecting and dragging them wit h the left mouse button.
EnerVista PMCS 6. 15 Quick Start Guide EnerVista System Tray Tool This is a simple tool for accessing the Se rver applications, in case user wants. This tool is automatically launched by the system while start- up and this is av ailable alwa ys as Tray Icon on the Task bar.
FAQ Understanding Enervista PMCS Architecture P M C S 6 . 1 5 i s d e s i g n e d t o c o m m u n i c a t e w i t h G E M o d b u s d e v i c e s . I t i s c o m p r i s e d o f t h e f o l l o w i n g components.
EnerVista PMCS 6. 15 Quick Start Guide Understanding Modbus device updat e times and system performance Subject: GE Multilin Modbus TCP/IP/RT U device update times Applies to: All GE Multilin Modbus d.
FAQ Modbus TCP/IP vs. Modbus RTU: Many people assume th at Modbus TCP/IP is ‘faster’ th an Modbus RTU due to the fact that it runs on Ethernet or a TCP/IP networ k. However since Mo dbus TCP/IP follows the same r ules as Modbus RTU the device update performance is almos t identical.
EnerVista PMCS 6. 15 Quick Start Guide and creates a Modbus requ est(s) for the required regist ers. If all the registers required can fit into one Modbus return message (124 register s in sequential order) than only one request for one block of data is made.
FAQ Data needed from each MLP QM. For this exampl e each PQM will r equire 5 modbus requests for the required data. Below is a breakdown of the example req uests.
EnerVista PMCS 6. 15 Quick Start Guide UR 1.1.1.2 2000ms 2000ms Multinet 1.1.1.3 1500ms 1500ms *ML750 1.1.1.4 1500m s 1500ms Enervista PMCS Enervista PMCS incorporate device ‘wiz ards’ or pre- made device graphics containing data point displays of typically required in a device.
An important point after buying a device GE PMCS 6.15 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought GE PMCS 6.15 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data GE PMCS 6.15 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, GE PMCS 6.15 you will learn all the available features of the product, as well as information on its operation. The information that you get GE PMCS 6.15 will certainly help you make a decision on the purchase.
If you already are a holder of GE PMCS 6.15, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime GE PMCS 6.15.
However, one of the most important roles played by the user manual is to help in solving problems with GE PMCS 6.15. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device GE PMCS 6.15 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center