Instruction/ maintenance manual of the product ASF-60G Alto-Shaam
Go to page of 37
PHONE: 262.
MN-35207 • Gas Fryer Operation & Care Manual Delivery ......................................... 1 Unpacking ....................................... 1 Safety Procedures and Precautions ................... 2 Installation Dimension Drawings, Weights & Capacities .
MN-35207 • Gas Fryer Operation & Care Manual • 1 DELIVERY This Alto-Shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier.
MN-35207 • Gas Fryer Operation & Care Manual • 2 INSTALLATION CAUTION Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
MN-35207 • Gas Fryer Operation & Care Manual • 3 INSTALLATION ASF-60 SPECIFICATIONS INSTALLATION 1-5/8" (41mm) 8-3/8" (212mm) ELECTRICAL 31-5/8" (803mm) GAS 3/4" (19mm) 15&.
MN-35207 • Gas Fryer Operation & Care Manual • 4 INSTALLATION INSTALLATION MINIMUM CLEARANCE REQUIREMENTS COMBUSTIBLE SURFACES NON - COMBUSTIBLE SURFACES RIGHT SIDE 6"(152mm) 0".
MN-35207 • Gas Fryer Operation & Care Manual • 5 INSTALLATION INSTALLATION 1. It is the responsibility of the installer to verify that this installation is in compliance with the specications listedin this manualand with local code requirements.
MN-35207 • Gas Fryer Operation & Care Manual • 6 INSTALLATION INSTALLATION VENTILATION 1. A single ASF-60G auto-lift gas fryer requires a minimum of 120 CFM make-up air for natural gas and 48CFM for propanegas. Kitchenventilation must be of sufficient capacity to prevent a negative-pressure condition.
MN-35207 • Gas Fryer Operation & Care Manual • 7 INSTALLATION INSTALLATION 35.15 I 2H(20), I 2E(20), I 2E.
MN-35207 • Gas Fryer Operation & Care Manual • 8 INSTALLATION INSTALLATION Use an approved gas pipe sealant at allexternal threaded connections, gas piping used on gas connections must avoid sharp bends that may restrict the ow ofgas to the appliance.
MN-35207 • Gas Fryer Operation & Care Manual • 9 INSTALLATION INSTALLATION The fryer must be supplied with a connector that complies with all state and local installation codes. A ny appliance that is not furnished with a power supply cord but that includes a set of casters must be tethered.
MN-35207 • Gas Fryer Operation & Care Manual • 10 INSTALLATION INSTALLATION An electrical wiring diagram is located in the fryer kettle. Thefryer must be installedby a qualied electrician.This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram.
MN-35207 • Gas Fryer Operation & Care Manual • 11 OPERATION OPERATION OIL/SHORTENING REQUIREMENTS Each ASF-60G frypot requires 62-pounds (28 kg) of oil or shortening.
MN-35207 • Gas Fryer Operation & Care Manual • 12 OPERATION NOTE: Perform an initial Boil-Out to clean and sanitize the fryer battery before operating.
MN-35207 • Gas Fryer Operation & Care Manual • 13 OPERATION PANEL IDENTIFICATION 1 6 7 2 4 8 9 1. LED Dis pL a y 2. Ho LD inDica t or 3. HEa t inDica t or 4. MEL t cy cLE inDica t or 5. pr o graM inDica to r 6. pr oDUct KEy inD ica tor LigHts: Illumina te during active cook cycle or pr og rammin g mo de.
MN-35207 • Gas Fryer Operation & Care Manual • 14 OPERATION Start a Cook Cycle Press any product key to start a cook cycle. If the key is programmed, the cooking time will be displayed and will immediately start to count down in minutes and seconds.
MN-35207 • Gas Fryer Operation & Care Manual • 15 OPERATION To Check Product Counts : press and hold the P key for 3 seconds. C OUNTS will be displayed. Press the P ke y. PR OD 1 will be displayed then the number of cooks that were completed on that key .
MN-35207 • Gas Fryer Operation & Care Manual • 16 OPERATION Product Ke y Programming 10 button controllers have a single, dual-purpose display that will alternate information; for example: then ENTER PROGRAMMING MODE. Press and hold the P key for 3 seconds.
MN-35207 • Gas Fryer Operation & Care Manual • 17 OPERATION T ype in 1 7 2 4 using the product keys. Press the P key. Press the P key . All product key LEDs will light up. PROGRAM A PRODUCT KE Y. Press the product key you want to program. Press the P ke y.
MN-35207 • Gas Fryer Operation & Care Manual • 18 OPERATION Press the P ke y. Press the up arrow ke y. Press the P key . Either press another product key to program and repeat the programming instructions, or continue by pressing the down arrow key .
MN-35207 • Gas Fryer Operation & Care Manual • 19 OPERATION ENTER SYSTEM PRO- GRAMMING MODE. Press and hold the P key for 3 seconds. T ype in 3 2 2 8 using the product keys. Press the P key. Press the down arrow key . Press the P key . SET APPLIANCE MODE.
MN-35207 • Gas Fryer Operation & Care Manual • 20 OPERATION ENTER LIBRARY PRO- GRAMMING MODE. Press and hold the P key for 3 seconds. T ype in 3 2 2 8 using the prod- uct keys. Press the P ke y. Press the down arrow key . Press the down arrow key to select either PRODLIBR OR ALRMLIBR.
MN-35207 • Gas Fryer Operation & Care Manual • 21 OPERATION OPERATION SUGGESTED FRYING TIMES iteM Minutes teMperAture DisplAy 1. Fries ( FROZEN ) 3:30 350°F (177°C) Fries 2. Chicken Nuggets ( FROZEN ) 3:30 350°F (177°C) Nuggets 3. Fish, Breaded ( FROZEN ) 4:30 350°F (177°C) Fish 4.
MN-35207 • Gas Fryer Operation & Care Manual • 22 OPERATION OPERATION SUGGESTED FRYING TIMES ITEM MINUTES TEMPERATURE Eggplant 4:00 340°F(171°C) Egg Rolls ( froZen ) 5:00 .
MN-35207 • Gas Fryer Operation & Care Manual • 23 CLEANING THOROUGHLY CLEAN DAILY The cleanliness and appearance of this unit will contributeconsiderably to operating efciency and savory, appetizing food. Good equipment kept clean works better and lasts longer.
MN-35207 • Gas Fryer Operation & Care Manual • 24 CLEANING NOTE: Perform an initial boil-out to clean and sanitize the fryer before operating. Carbonized deposits along with an accumulation of oil will eventually build-up on the interior of the frypot as well as fryer accessories.
MN-35207 • Gas Fryer Operation & Care Manual • 25 CLEANING 6. Add boil out solution. Carefully follow the manufacturer’sdirections for mixing theboil-out solution. 7. Turn the Master Power Switch (located behind the front access door) to the “ON” position and press the CONTROL RESET .
MN-35207 • Gas Fryer Operation & Care Manual • 26 SERVICE PROBLEM CAUSE SOLUTION N o p ow er Circuit b reaker OFF Check and r es et A pplia nce not pl ug ged in Plug in co rd Defective 24V AC .
MN-35207 • Gas Fryer Operation & Care Manual • 27 SERVICE DANGER DISCONNECT UNIT FROM POWER SOURCE BEFORE CLEANING OR SERVICING. CAUTION THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL .
MN-35207 • Gas Fryer Operation & Care Manual • 28 SERVICE REAR 3 4 5 6 1 2 90.0° 67492 7 8 10 9 11 12 ITEM P/N DESCRIPTION QTY 1 PE-29469 Panel Overlay 1 2 HG-2015 Hinge Assembly 2 SC-2072 Sc.
MN-35207 • Gas Fryer Operation & Care Manual • 29 SERVICE 37 36 20 19 18 25 34 5 4 32 6 7 17 8 9 10 14 29 12 28 27 11 13 16 2 24 3 33 35 21 23 22 26 30 31 1 15 5014927 6 REVISION ITEM P/N DESC.
MN-35207 • Gas Fryer Operation & Care Manual • 30 SERVICE ASF-60G 120V ELECTRICAL PACKAGES 6 7 1 3 2 4 1 5014939 5014928 120V ELEC. LIFT PKG. ASF-60G 67501 4 5 ITEM P/N DESCRIPTION 120V with L.
MN-35207 • Gas Fryer Operation & Care Manual • 31 SERVICE LIFT ASSEMBLY – 5014863 shown Part numbers and drawings are subject to change without notice.
MN-35207 • Gas Fryer Operation & Care Manual • 32 SERVICE ITEM DESCRIPTION P/N QTY 1 Nut, #8-32 UNC KEPS ZP NU-26526 8 2 1/2" Self Adhesive Gasket 3ft GS-2019 1 3 Control, ASF-60, 10 Butt.
MN-35207 • Gas Fryer Operation & Care Manual • 33 SERVICE ELECTRICAL ASSEMBLY, 120V – ASF-60G 1 4 3 2 5014823 120V CONFIGURATION 8 11 15 16 17 18 19 6 9 10 12 5 2 13 14 13 20 21 7 * not shown Part numbers and drawings are subject to change without notice.
MN-35207 • Gas Fryer Operation & Care Manual • 34 SERVICE ELECTRICAL ASSEMBLY, 5014722.
TRANSPORTATION DAMAGE and CLAIMS All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee.
An important point after buying a device Alto-Shaam ASF-60G (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Alto-Shaam ASF-60G yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Alto-Shaam ASF-60G - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Alto-Shaam ASF-60G you will learn all the available features of the product, as well as information on its operation. The information that you get Alto-Shaam ASF-60G will certainly help you make a decision on the purchase.
If you already are a holder of Alto-Shaam ASF-60G, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Alto-Shaam ASF-60G.
However, one of the most important roles played by the user manual is to help in solving problems with Alto-Shaam ASF-60G. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Alto-Shaam ASF-60G along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center