Instruction/ maintenance manual of the product MT113-100 Altinex
Go to page of 24
MULTITASKER ™ MANUAL PART NUMBER: 400 - 0209 - 002 3- IN MIXER 1 - OUT, + 15W STEREO AUDIO POWER AMPLIFIER CARD FOR MULTIT ASKER USER’S GUIDE MT 113 - 100 MT 113 - 101 MT113 - 100/101.
MULTITASKER ™ 400 - 0209 - 002 1 1 TA BLE OF CONTENTS Page PRECAUTIONS / SAFETY WA RNINGS ............... 2 GENERAL .......................................................... 2 CLEANING ......................................................... 2 FCC / CE NOTICE .
MULTITASKER ™ 400 - 0209 - 002 2 2 PRECA UTIONS / SA FETY WA RNINGS 1 Please read this manual carefully before using your MT113 - 100/101 . Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MT113 - 100/101 and to prevent fire and shock hazard.
MULTITASKER ™ 400 - 0209 - 002 3 3 AB OUT YOUR MT113 - 100/101 2 MT 113 - 100/101 3 in Mixer, 1 fixed line level output and 30W amplifier Card The MT113 - 100/101 is a Stereo Audio Power Amplifier Card de signed for use with the MultiTasker. This card allows the connection of up to two line level balanced/ unbalanced inputs and one microphone.
MULTITASKER ™ 400 - 0209 - 002 4 4 DESCRIPTION OF MT113 - 100/101 4 MT113 - 10 0 DESCRIPTION.
MULTITASKER ™ 400 - 0209 - 002 5 5 MT113 - 101 DESCRIPTION.
MULTITASKER ™ 400 - 0209 - 002 6 6 AP PLICA TION DIA GRA MS 5 DIA GRA M 1 : MT113 - 100 TYPICA L SETUP DIA GRA M 2 : MT113 - 101 TYPICA L SETUP.
MULTITASKER ™ 400 - 0209 - 002 7 7 DIA GRA M 3 : MT 113 - 100 INTERNA L VIEW 70V X-FORMER CONTROL POWER SUPPLY S/W VOLUME BASS TREBLE GAIN MP OR ADJ FIX LINE OUTPUT + - OFF + - ON PHANTOM POWER ON O.
MULTITASKER ™ 400 - 0209 - 002 8 8 DIA GRA M 4 : MT113 - 10 1 INTERNA L VIEW x POWER SUPPLY POWER PHANTOM CONTROL MP S/W VOLUME BASS TREBLE GAIN OR ADJ FIX LINE OUTPUT + - OFF + - ON PHANTOM POWER O.
MULTITASKER ™ 400 - 0209 - 002 9 9 INSTA LLING YOUR MT113 - 100/101 6 Step 1. Turn off power to the MultiTasker enclosure. Step 2. Slide the MT113 - 100/101 into an available slot in the MultiTasker Enclos ure in order to connect to the bus. Make sure that the MT113 - 100/101 card fits into place.
MULTITASKER ™ 400 - 0209 - 002 10 10 Command Format: [VERCnUi] Cn = Card ID (n = slot # from 1 to max slots) Ui = Unit ID (i = # from 0 to 9) Example: An MT113 - 100/101 card is in slot #4.
MULTITASKER ™ 400 - 0209 - 002 11 11 690 - 0122 - 015 = Version 015 or later. 690 - 0123 - 004 = Version 004 or later. 690 - 0124 - 018 = Version 018 or later.
MULTITASKER ™ 400 - 0209 - 002 12 12 Example: Select the Output Volume command for the card in slot #4. The current Output Volume level is 10, but it is not the optimal value. After sending the following commands, an optimum volume level of 15 is obtained: 1.
MULTITASKER ™ 400 - 0209 - 002 13 13 Command Format: [VLOAmCnUi] m = Volume Level (m = # from 0 to 16) Cn = Card ID (n = slot # from 1 to max slots) Ui = Unit ID (i = # from 0 to 9) Example: Set the output volume to 16 for the MT113 - 100/101 in slot #4 .
MULTITASKER ™ 400 - 0209 - 002 14 14 Example: Turn on the speaker ports of the MT113 - 100/101 in slot #4 by sending the command [ MUT0 C4]. 21. [MUT1] This command dis ables the speaker output .
MULTITASKER ™ 400 - 0209 - 002 15 15 Command Format: [RUP=xxCnUi] xx = Stop Level (xx = # from 01 - 16) Cn = Card ID (n = # from 1 to max slots) Ui = Unit ID (i = # from 0 to 9) Example: Ramp the output volume from a starting level of 1 up to 10. Send the command [RUP=10C8] and receive the following feedback: [02][03][04]… [10] 25.
MULTITASKER ™ 400 - 0209 - 002 16 16 Example: There is an MT113 - 100/101 in slot #5. Send the command [RAMP=16C5] to set the ramp rate to 16 seconds. After this is set, any ramping will occur at a rate of 16 steps in 16 seconds, or 1 second per step.
MULTITASKER ™ 400 - 0209 - 002 17 17 32. [RSI] This command resets the card ID's in the system. After sending this command, each card ID in the system will match the slot number of the card. Use this command along with the SID commands that follow.
MULTITASKER ™ 400 - 0209 - 002 18 18 3 7. [HELP] This command displays information available for the MultiT asker interface commands. Command Format: [HELPCnUi] Cn = Card ID (n = # from 1 to max slo.
MULTITASKER ™ 400 - 0209 - 002 19 19 REMOVE ALL GROUPS Remove all the members from every group, effectively deleting all groups. Command Format: [RMG * Ui] Ui = Unit ID (i = # from 0 - 9) Example: Group 1 consists of cards 1 and 2. Group 2 consists of cards 1, 2, 3, 4 and 5.
MULTITASKER ™ 400 - 0209 - 002 20 20 22) [CLR] Reset card to default values 23) [RUP] Ramp volume UP to max (16) 24) [RUP=] Ramp volume UP to a value 25) [RDN] Ramp volume DOWN to min (1) 26) [RDN=].
MULTITASKER ™ 400 - 0209 - 002 21 21 7.4.2 USING MENU MODE SUGGESTION: Before using the menu mode, it is best to disable the automatic feedback feature. The val ues and current settings will be displayed in the menu mode, but the automatic feature will display after each setting change making the menus difficult to read.
MULTITASKER ™ 400 - 0209 - 002 22 22 2. Set Input 3 Volume Starting from the Main Menu, set Input 3 volume level to 16. Follow the keystrokes below. 2 Select SETUP Menu 2 Select Set Input Volume 3 Select Input 3 Volume 16 Enter 16 NOTE The system may echo the 1 and the 6 entries, depending on the settings.
MULTITASKER ™ 400 - 0209 - 002 23 23 Cause 2: The card settings are w rong . Solution: Verify the card volume settings are at ma ximum and that mute is off. (See section 7 ) . If no sound is present, see Cause 3. Cause 3: Cable connections are incorrect.
An important point after buying a device Altinex MT113-100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Altinex MT113-100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Altinex MT113-100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Altinex MT113-100 you will learn all the available features of the product, as well as information on its operation. The information that you get Altinex MT113-100 will certainly help you make a decision on the purchase.
If you already are a holder of Altinex MT113-100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Altinex MT113-100.
However, one of the most important roles played by the user manual is to help in solving problems with Altinex MT113-100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Altinex MT113-100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center