Instruction/ maintenance manual of the product FRS123LW1 Frigidaire
Go to page of 27
Model(indoor/outdoor): FRS093LW1/FRS093LC1 FRS123LW1/FRS123LC1 a c . e r i a d i g i r f . w w w m o c . e r i a d i g i r f . w w w All a bout th e Installation of y ou r Split Type Room Air Conditio.
04 Safety precautions DANGER! Avoid Serious Injury or Death 1. Do not attempt to install the split air conditioner by yourself. 2. This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs. 3. When moving the air conditioner, always call an authorized Electrolux servicer for disconnection and re-installation.
T o prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. 1.
operation. It may cause electric removed, do not touch the metal parts of the unit. It may cause an injury . Safety precautions shock or injury. and electric shock. It may cause failure of appliance 11.Do not open the unit during 13.Do not disassemble or modify unit.
07 8. The site must allow for the easy removal of the connector pipe and drain hose. 9. The unit must be installed at a site protected from direct sunlight. Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install 2.
Outdoor Unit 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of increased noise and vibration at the site.
P arts list 2 5 4 3 1 Indoor unit Outdoor unit P arts list Installation plate Clip anchor Seal Drain Joint . 1 2 3 4 5 1 2 1 1 10 8 1 1 Remote controller Remote Controller holder Connecting pipe assem.
Attention 1. This illustration is for explanation purposes only . 5 4 2 3 1 Indoor unit Outdoor unit 6 Air filter More A B C P arts list 2. Copper tubes must be insulated independently More than 5" More than 6" More than 5" 8 9 10 6 7 More than 2 feet than 2 feet More than 6.
11.
Attention Fixing the Installation Plate Drilling the Hole 1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown 2. In the case of tiled, concrete or diameter holes. Place anchorage supports for the appropriate assembly screws.
Connective pipe and drainage installation Drainage 1. Run the drain hose sloping downward. Do not install the drain 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack.
Attention Piping and wrapping 1. Bundle the tubing, connecting cable, and drain hose with tape 2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is anything else in the box. 1. Connect the indoor unit first, then the outdoor unit.
1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles. especially in areas where it is frequently windy . 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates.
Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid Fit the seal into the drain elbow , then insert the drain joint into the base pan hole of outdoor unit, rotate 90 o to securely assemble them. Connect the drain joint with an extension drain hose (Locally purchased), in case of the water draining off the outdoor unit during the heating Air inlet Air inlet Air outlet A B Outdoor unit installation Base pan hole of outdoor unit Seal Drain joint Seal Drain pipe += Drain joint installation mode or rainy season.
Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A) Use the piping kit accessory or pipes purchased locally . B) Measure the distance between the indoor and the outdoor unit.
4. Flaring work. die in the dimension shown in the table below . OUTER Connection Adjustment 1. Align the pipes to be connected. OUTER TIGHTENING Caution: Excessive twisting may break the nut, depending on the installation conditions. R efrigerant piping connection Bar pipe Handle Clamp handle Y oke Red arrow mark Flare nut Pipings Indoor unit tubing Copper A (inch) Max.
.
1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw .
Electrical work COOLING MODEL HEA TING AND COOLING MODE HEA TING AND COOLING MODEL 1 2(N) 3 4 1 2(N) 3 4 or T erminal block of indoor unit T erminal block of indoor unit T erminal block of indoor unit.
1. Remove the electrical control board cover from the outdoor unit by loosening the screw . 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. The connective cable to power supply shal l be approved polychloroprene sheathed flexible cord .
Electrical work COOLING MODEL HEA TING AND COOLING MODEL HEA TING AND COOLING MODEL or o or or "Conector A" "Conector A" "Conector C” "Conector B" "Conector B.
1. Never fail to have an individual power circuit specifically for the air conditioner . As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover . liable to come loose from vibrations to which the unit is subjected during the course of transportation.
Air purging with vacuum pump 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit.
Air purging V acuum pump Charge hose Manifold valve -76cm/Hg Charge hose Handle Lo Handle Hi Outdoor unit Indoor unit When using the vacuum pump F or method of using a manifold valve, refer to its operation manual. manifold valve. evacuate. After starting evacuation, slightly loose the flare nut of the Lo valve on the gas pipe side and check if the air is entering (Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus), then tighten the flare nut.
Electrical safety P erform the electric safe ty check after completing installation: Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of th e piping.
T est running P erform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Connect the power , press the ON/OFF button on the remote controller to turn the unit on. cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken.
1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner , ensure that the air filter is installed correctly .
An important point after buying a device Frigidaire FRS123LW1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Frigidaire FRS123LW1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Frigidaire FRS123LW1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Frigidaire FRS123LW1 you will learn all the available features of the product, as well as information on its operation. The information that you get Frigidaire FRS123LW1 will certainly help you make a decision on the purchase.
If you already are a holder of Frigidaire FRS123LW1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Frigidaire FRS123LW1.
However, one of the most important roles played by the user manual is to help in solving problems with Frigidaire FRS123LW1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Frigidaire FRS123LW1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center