Instruction/ maintenance manual of the product U32-LP2 FPI
Go to page of 28
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-011a MODELS: U32-NG2 Natural Gas U32-LP2 Propane WARNING: Improper installation, adjustment, alteration, service or main - tenance can cause injury or property damage.
2 U32-2 FPI Direct Vent Gas Insert FPI GAS INSERT Note: Oversize faceplate is 44" x 28" TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Insert by FPI. The FPI Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch.
3 U32-2 FPI Direct Vent Gas Insert T ABLE OF CONTENTS FPI GAS INSERT Operating Instructions Operating Instructions ......................................................... 1 7 Lighting Procedure .......................................................
4 U32-2 FPI Direct Vent Gas Insert SAFETY LABEL This is a copy of the labels that accompany each U32-2 Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened.
5 U32-2 FPI Direct Vent Gas Insert IMPORT ANT : SA VE THESE INSTRUCTIONS The FPI Gas Insert must be installed in accord- ance with these instructions. Carefully read all the instructions in this manual first. Consult the building authority having jurisdiction to deter- mine the need for a permit prior to starting the installation.
6 U32-2 FPI Direct Vent Gas Insert MA TERIALS REQUIRED No electrical power supply is required for the gas control to operate. A 120 Volt AC power cord is hooked up to the fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circum- stances.
7 U32-2 FPI Direct Vent Gas Insert GAS CONNECTION GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. 1) If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fireplace.
8 U32-2 FPI Direct Vent Gas Insert OPTIONAL BRICK P ANEL 1) Unwrap the brick pattern panels from the protective wrapping. 2) Remove the glass front if it is already installed, see page 11. 3) Put the rear brick panel flat against the back of the unit.
9 U32-2 FPI Direct Vent Gas Insert Logs D)02-46 and E)02-47 in position. 6) Place the Left Top Log D)02-46 on the pin on Log C)02-56 and on top of the cutout on Log A)02-43. 7) Place the notch in Center Log E)02-47 over Log B)02-45 and across the cutout on Log A)02-43.
10 U32-2 FPI Direct Vent Gas Insert Diagram 3 Rear View: Trim Assembly Diagram 2 Rear View: Faceplate Assembly Diagram 1 F ACEPLA TE & TRIM INST ALLA TION 1) Lay the faceplate panels flat, face down on something soft so they don't scratch. 2) Take the top faceplate and align the holes in it with the holes in the side panels.
11 U32-2 FPI Direct Vent Gas Insert To remove the flush door, reverse the above steps. NOTE: The chain must rest on TOP of the gas inlet pipe never under it. Diagram 3 Diagram 2 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket.
12 U32-2 FPI Direct Vent Gas Insert INST ALLA TION BA Y LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fitted louver leaves a small gap between faceplate bot- tom and louver top.
13 U32-2 FPI Direct Vent Gas Insert HAMPTON CAST F ACEPLA TE INST ALLA TION 1) Lay the faceplate panels flat, face down on something soft so they don't scratch. 2) Attach the side filler brackets to the left and right sides using 3 screws and washer per side.
14 U32-2 FPI Direct Vent Gas Insert HAMPTON CAST FACEPLA TE GRILL INST ALLA TION 1) Install logs and flush glass before going on to the next step. See manual for details. 3) The top louver, shown in diagram 1, is held in place by friction fit, if the louver needs to be adjusted; bend the convex bracket out as shown in diagram 2.
15 U32-2 FPI Direct Vent Gas Insert OPTIONAL REMOTE CONTROL Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
16 U32-2 FPI Direct Vent Gas Insert WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
17 U32-2 FPI Direct Vent Gas Insert AUTOMA TIC CONVECTION F AN OPERA TION The fan operates automatically, turn the knob on the side of the faceplate to adjust to the desired speed.
18 U32-2 FPI Direct Vent Gas Insert COPY OF LIGHTING INSTRUCTION PLA TE OPERA TING INSTRUCTIONS Blower Thermodisc: When this thermally activated switch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal.
19 U32-2 FPI Direct Vent Gas Insert Flush Glass Replacement Remove the flush door front (as per instruc- tions on page 11). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame. MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually.
20 U32-2 FPI Direct Vent Gas Insert FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place.
21 U32-2 FPI Direct Vent Gas Insert MAINTENANCE V AL VE REPLACEMENT 1 ) Shut off the gas supply. 2) Remove the louvers (and bay door if it is on). 3) Open the flush door and remove the door. 4) Remove the logs and brick panels. 5) Remove the grate by loosening the two screws and sliding the grate out.
22 U32-2 FPI Direct Vent Gas Insert P ARTS LIST 1 ) 420-122 Fan Access Panel 2 ) 420-142 Gasket - Fan Access Panel 422-518/P Fan Assembly: 3 ) 910-215/P Fan Motor (120 V) 5 ) 910-750 Power Cord (120 V.
23 U32-2 FPI Direct Vent Gas Insert P ARTS LIST 422-574/P Valve Assembly - NG 422-576/P Valve Assembly - LP 52) 910-040 Valve - Robertshaw NG 53) 910-190 Ignitor Piezo and Nut 54 ) * Valve Heat Shield 55 ) * Valve Tray 58) 904-240 Burner Orifice Nat.
24 U32-2 FPI Direct Vent Gas Insert P ARTS LIST Bay Door 420-931 Complete Bay Door with Black Trim 102) * Glass Retainer Side (Top & Btm) 103) * Glass Retainer Front (Top & Btm) 106) 940-315/P.
25 U32-2 FPI Direct Vent Gas Insert PARTS LIST 402-919 Complete Faceplate (Set) Contour with Black Trim-Oversize 51 ) * Faceplate Side Right - Oversize 59 ) * Faceplate Top - Oversize 60 ) * Faceplate Side Left Assy-Oversize 402-534 Trims Pkg.
26 U32-2 FPI Direct Vent Gas Insert 402-971 Cast Faceplates (Set) - Black Metallic 402-976 Cast Faceplates (Set) - Black Enamel 187) 910-246 Burner On/Off Switch 188) 910-330 Fan Speed Control (120 V).
27 U32-2 FPI Direct Vent Gas Insert W ARRANTY FPI fireplaces are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd.
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Instal.
An important point after buying a device FPI U32-LP2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought FPI U32-LP2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data FPI U32-LP2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, FPI U32-LP2 you will learn all the available features of the product, as well as information on its operation. The information that you get FPI U32-LP2 will certainly help you make a decision on the purchase.
If you already are a holder of FPI U32-LP2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime FPI U32-LP2.
However, one of the most important roles played by the user manual is to help in solving problems with FPI U32-LP2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device FPI U32-LP2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center