PN 4060712 April 2012 © 2012 Fluke Corporation. All rights reserved. Pri nted in China. Specifications are subject to change withou t notice. All product names are trademarks of their respectiv e companies.
LIMITED WARRANTY AND LIMITATION OF LI ABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchas e. This warrant y does not cover fuses, disposab le batteries, or damage from accident, neglect, misuse, alter ation, contamination, or abnormal conditions of operation or ha ndling.
i Table of Contents Title Page Introduction ................................................................................................................. 1 How to Contact Fluke ......................................................................
62 MAX/62 MAX + Users Manual ii.
1 Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermo meters (the Product) can determine the surface temperature by measuring the amount of infrared energy radiated by the target’s surface. Note that the Japanese models indicate Celsius only.
62 MAX/62 MAX + Users Manual 2 Or, visit Fluke's website at www.fluke.com . To register your product, visit http://register.fluke.com . To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals . Safety Information A Warning identifies conditions and procedures that are dangerous to the user.
Infrared Thermometer Safety Information 3 • See emissivity information for actual temperat ures. Reflective objects result in lower than actual te mperature measuremen ts. These objects pose a burn hazard. • Do not look directl y into the laser w ith optical tools (for e xample, binoculars, telescopes, micros copes ).
62 MAX/62 MAX + Users Manual 4 Table 1. Symbols Symbol Meaning Symbol Meaning W Risk of danger. Important information. See Manual. ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information. * Warning.
Infrared Thermometer Maintenance 5 Maintenance W Caution To avoid damag e to the Product, do n ot leave the ther mometer on or near objects of high tem perature. How to Change the Battery To install or change the AA IEC LR06 battery, open the battery compartment a nd replace the battery as shown in Figure 16.
62 MAX/62 MAX + Users Manual 6 Specifications 62 MAX 62 MAX + Temperature Range -30 ° C to 500 ° C (-22 ° F to 932 ° F) -30 ° C to 650 ° C (-22 ° F to 1202 ° F) Accuracy ≥ 0 ° C: ± 1.5 ° C or ± 1.5 % of reading, whichever is greater ( ≥ 32 ° F: ± 3 ° F or ± 1.
Infrared Thermometer Specifications 7 Optical Resolution 10:1 (calculated at 90 % energy) 12:1 (calculated at 90 % energy) Display Resolution 0.1 ° C (0.2 ° F) Repeatability (% of reading) ± 0.8 % of reading or ± 1.0 ° C (2 ° F), whichever is greater ± 0.
62 MAX/62 MAX + Users Manual 8 IP Rating IP 54 per IEC 60529 Drop Test 3 meters Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g , 11 ms EMC EN 61326-1:2006 EN 61326-2:2006 Standards and Agency Approval Compliance ................
Infrared Thermometer The Product 9 The Product 1 2 gtt01.eps.
62 MAX/62 MAX + Users Manual 10 3 4 Max/Min/A vg/Diff / 5 56 gtt14.eps.
Infrared Thermometer The Product 11 7 10 min OFF + = gtt16.eps.
62 MAX/62 MAX + Users Manual 12 9 11 125°F 8 10 0ºC 32ºF 22ºC 72ºF 12 6 3 9 30 Min gtt15.eps.
Infrared Thermometer The Product 13 12 13 38 mm @ 300 mm 60 mm @ 600 mm 100 mm @ 900 mm 1.5" @ 12" 2.4" @ 24" 4" @ 36" D S 62 MAX D:S = 10:1 33 mm @ 300 mm 50 mm @ 600 mm 85 mm @ 900 mm 1.4" @ 12" 2" @ 24" 3.
62 MAX/62 MAX + Users Manual 14 14 70 21 gtt03.eps.
Infrared Thermometer The Product 15 15 75° 75° 225° gtt04.eps.
62 MAX/62 MAX + Users Manual 16 16 17 + - gtt13.eps.
An important point after buying a device Fluke PN 4060712 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Fluke PN 4060712 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Fluke PN 4060712 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Fluke PN 4060712 you will learn all the available features of the product, as well as information on its operation. The information that you get Fluke PN 4060712 will certainly help you make a decision on the purchase.
If you already are a holder of Fluke PN 4060712, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Fluke PN 4060712.
However, one of the most important roles played by the user manual is to help in solving problems with Fluke PN 4060712. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Fluke PN 4060712 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center