Instruction/ maintenance manual of the product PN 3612805 Fluke
Go to page of 22
PN 3612805 July 2010 © 2010 Fluke Corp oration. All ri ghts reserved. Pr inted in Taiwan. S pecifications are subject to chang e without no tice. All product nam es are trademarks o f their respecti ve companies.
LIMITED WARRANTY A ND LIMITATION OF LIA BILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchas e. This warrant y does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alter ation, contamination, or abnormal conditions of operation or ha ndlin g.
i Table of Contents Title Page Introduction ................................................................................................................. 1 How to Contact Fluke ......................................................................
373 Users Manual ii.
1 Introduction XW Warning Read "Safety Information" before you use the Meter. The Fluke 373 Clamp Meter (the Meter) measures true-rms ac and dc voltage, ac current, resistance, and capacitance.
373 Users Manual 2 Or, visit Fluke's website at www.fluke.com . To register your product, visit http://register.fluke.com . To see, print, or download the latest manual supplement, visit http://us.
Clamp Meter Safety Information 3 • Remove the test leads from the Meter before th e battery door is opened. • Examine the test leads for damaged insulation o r exposed metal. Check test lead continuity. Repl ace damaged test leads be fore using the Meter.
373 Users Manual 4 • Connect the common t est lead before co nnecting the li ve test lead. When disconnecting test lea ds, disconnect the li ve test lead first. • Do not work alone so assista nce can be rendered in a n emergency. • Use extreme caution w hen working aroun d bare conductors or bus bars.
Clamp Meter Safety Information 5 Table 1. Symbols Symbol Meaning S ymbol Meaning B AC (Alternating Current) J Earth ground F DC (Direct Current) ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.
373 Users Manual 6 Symbol Meaning S ymbol Meaning CAT III IEC Measurement Category III CAT III equipment has protection against transients in equipment in fixed-equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings.
Clamp Meter The Meter 7 The Meter 1 ghl008.eps.
373 Users Manual 8 Auto Off 20 ghl001.eps.
Clamp Meter The Meter 9 Backlight ghl002.eps.
373 Users Manual 10 A ghl003.eps.
Clamp Meter The Meter 11 V V V V or > 30 V ghl004.eps.
373 Users Manual 12 < 30 ghl005.eps.
Clamp Meter The Meter 13 CAT III 600 V CAT I V 300 V 1 3 2 HOLD HOLD ghl006.eps.
373 Users Manual 14 1 2 3 ghl007.eps.
Clamp Meter The Meter 15 Electrical Specifications AC Current Range ..................................................... 600.0 A Resolution ............................................... 0.1 A Accuracy ...............................................
373 Users Manual 16 Accuracy ................................................. 1 % ± 5 digits Continuity Beeper ................................... ≤ 30 Ω Capacitance Range ..................................................... 10.0 – 100.0 μ F / 1000 μ F Resolution .
Clamp Meter The Meter 17 Operating Altitude ................................... 3000 meters Storage Altitude ...................................... 12,000 meters EMI, EMC ................................................ Meets all applicable requirements in EN61326-1:2 006 Temperature Coefficients .
373 Users Manual 18.
An important point after buying a device Fluke PN 3612805 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Fluke PN 3612805 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Fluke PN 3612805 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Fluke PN 3612805 you will learn all the available features of the product, as well as information on its operation. The information that you get Fluke PN 3612805 will certainly help you make a decision on the purchase.
If you already are a holder of Fluke PN 3612805, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Fluke PN 3612805.
However, one of the most important roles played by the user manual is to help in solving problems with Fluke PN 3612805. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Fluke PN 3612805 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center