Instruction/ maintenance manual of the product 561 Fluke
Go to page of 22
® 561 HV A CPr o Infrared Thermometer Users Manual PN 2562924 February 2006 © 2006 Fluke Corp oration, All ri ghts reserved. Pr inted in USA All product names ar e trademarks of their respective c ompanies.
LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defect s in material and workmanship for two years from the date of purchase. This warranty do es not cover fuses, disposable batteries, or damage from accident, neglect , misuse, alteration, contamination, or abnormal conditions of operation or handling.
i Table of Contents Title Page Introducti on ............................................................................................. 1 Contacting Fluke ...................................................................................... 1 Safety Information .
561 HVACPro Users Manual ii Measuring Grille, Registe r, or Diffuser Discharge Tempe rature ......... 15 Verifying Thermostat/ Room Sensor Acc uracy .................................... 15 Checking for Blockage in Air-To-Air Evaporators or Condensers.
1 561 HVAC PRO Infrared Thermometer Introduction The Fluke Model 561 HVACPro Infrared Thermometer (hereafter, “the Thermometer”) can determine the surface temperature by measuring the amount of infrared energy radiated by the ta rget’s surface or by contact using a thermocouple probe.
561 HVACPro Users Manual 2 Safety Information W Warning A Warning identifies conditi ons and actions that pose haz ards to the user. To avoid el ectrical shock or personal injury, foll ow these guidelines: • * Do not point laser direct ly at eye or indirectly off reflective surfaces.
Infrared Thermometer Features 3 A V O I D E X P O S U R E - L A S E R R A D IA T IO N IS E M IT T E D F R O M T H IS A P E R T U R E CA UTION L A S E R R A D IA T IO N - D O N O T S T A R E IN T O B E.
561 HVACPro Users Manual 4 AA Batteries (2) Display Function Buttons Laser T rigger Battery Cover efh007f.eps Figure 2. Infrared Th ermometer Display The primary temperature display reports the current or last IR temperature read until the 7-second hold time elapses.
Infrared Thermometer Buttons and Connector 5 3 4 5 6 2 1 8 7 efh01f.eps A Laser “On” symbol B SCAN or HOLD C ° C/ ° F symbol (Celsius/Fahrenheit) D Primary temperature display E Secondary temperature display F Emissivity LO, MED, HI G Temperature values for the MIN, MAX, DIF, KTC.
561 HVACPro Users Manual 6 How the Thermometer Works Infrared thermometers m easure the surface tempera ture of an opaque object. The Thermometer’s optics sense infrared energy, whic h is collected and focused onto a detector.
Infrared Thermometer Operating the Thermometer 7 D:S=12:1 38 mm @ 300 mm 75 mm @ 900 mm 132 mm @ 1500 mm 1.5 " @ 12 " 3 " @ 36 " 5.3 " @ 60 " S D efh005f.eps Figure 5. Distance and Spot Size Field of View Make sure that the target is larger than the spot size .
561 HVACPro Users Manual 8 Table 2. Surface Emissi vity Measured Surface Switch Setting Measured Surface Switch Setting Aluminum Iron, Cast Oxidized Low Oxidized High, Medium Alloy A3003 Unoxidized Lo.
Infrared Thermometer Operating the Thermometer 9 Switch efh012f.eps Figure 7. Switching Bet ween ° C and ° F Using the Contact Temperature Probe XW Warning To avoid electri cal shock or personal injury, do not connect the optional external probe to l ive electrical circuits.
561 HVACPro Users Manual 10 Table 3 lists recommended Fluke temperatur e probes for use with the Thermometer: Table 3. Recommended Tem perature Probes Probe Usage 80PK-25 The piercing probe is the most versatile option.
Infrared Thermometer Typical Measurements 11 • The most likely conditions for condensation form ation are low dry bulb te mperat ure and high wet bulb temperature (low temperat ure, high relat ive humidity). • Use the Fluke 971 to measure the attic/crawlspace relative humidity and determine the dew point temperature.
561 HVACPro Users Manual 12 Testing Contactors (Starters) 1. Press D to select emissivity. Press A to select LO for bright c ontacts, or MED for darkened contacts. 2. Press C and the press A to select MAX. 3. Measure line and load side of one pole without releasing trigger.
Infrared Thermometer Typical Measurements 13 Testing Bearings W Warning To avoid injury when t esting bearings: • Do not wear loose clothi ng, jewelry, or anything around neck when working around moving parts such as motors, belts, blower, and f ans.
561 HVACPro Users Manual 14 wall you should find parallel isotherm al rows indicating the location of heat t ubes below the surface. Perpendicular to the outside wall, you should fi nd rising and falling temp erat ures at equal distances.
Infrared Thermometer Typical Measurements 15 • If system pressure has been incr eased above design settings, this can result in sympto m of trap failure (stuck open). Check steam pressure. 1. Press D and then press A to select HI emissivity for bl ack iron pipe and painted traps.
561 HVACPro Users Manual 16 • All condenser return bend/hairpi ns should be at or slightly less than condenser saturation temperature. • If a group of return bends/hairpins do not confor m to expected temperatures, that indicates a blocked or restricted distri butor or dist ributor tube.
Infrared Thermometer Maintenance 17 Maintenance Changing the Battery To install or change the two AA batteries, open the battery compartment and insert the batteries as shown in Figure 2. Cleaning the Lens Blow off loose particles using clean compressed air.
561 HVACPro Users Manual 18 Specifications Infrared Measurement Range ................................................................ -40 ° C to 550 ° C (-40 ° F to 1022 ° F) Spectral Range ........................................................
An important point after buying a device Fluke 561 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Fluke 561 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Fluke 561 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Fluke 561 you will learn all the available features of the product, as well as information on its operation. The information that you get Fluke 561 will certainly help you make a decision on the purchase.
If you already are a holder of Fluke 561, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Fluke 561.
However, one of the most important roles played by the user manual is to help in solving problems with Fluke 561. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Fluke 561 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center