Instruction/ maintenance manual of the product 233 Fluke
Go to page of 16
233 True-rms Remote Display Digital Multimeter PN 3465366 September 2009 © 2009 Fluke Corporation. All rights rese rved. Pri nted in USA. S pecifications are subject to change without notice. All product names are trademarks of their respectiv e companies.
LIMITED WARRANTY A ND LIMITATION OF LIA BILITY This Fluke product will be free from defects in material and wo rkmanship for three years from the date of purchase. T his warranty does not cover fuses, disposable batteries, or damage from accid ent, neglect, misuse, alteration, contamination, or abnormal conditions of operation or ha nd ling.
1 Introduction The Fluke 233 (hereafter the Meter) is a co mpact and easy to operate tool for electr ical and electronic circuit measurements. XW Warning Read "Safety Information " before you use the Meter.
233 Getting Started Manual 2 Safety Information The Meter complies with: • ISA-82.02.01 • CAN/CSA C22.2 No. 61010-1-04 • ANSI/UL 61010-1:2004 • EN 61010-1:2001 • EN 61326-1:2006 • EN 61326-2-2:200 6 • ETSI EN 300 328 V1.7.1:2006 • ETSI EN 300 489 V1.
True-rms Remote Display Digital Multimeter Safety Information 3 • Remove the test leads from th e Meter before the battery door on the Meter base is opened. • Examine the test leads for damaged insulation or exposed metal. Measure th e test leads for continuity.
233 Getting Started Manual 4 • Use only specified 1.5-V AA batteries (three in the Meter base and two in the display), correctly installed, for Meter power.
True-rms Remote Display Digital Multimeter Safety Information 5 Table 1. Electrical Symbols B AC (Alternating Current) J Earth ground F DC (Direct Current) I Fuse X Hazardous voltage P Conforms to European Union directives. W Risk of Danger. Important information.
233 Getting Started Manual 6 Features See Tables 3 through 4 for a list of Meter features with a short feature descriptio n. Table 2. Display meter remote Auto RangeManual Range 1 2 3 4 5 6 8 9 11 13 12 14 10 7 gcc101.eps No. Symbol Indication 1 MIN MAX AVG mode on.
True-rms Remote Display Digital Multimeter Features 7 Table 2. Display (cont.) No. Symbol Indication 4 Radio connection indicat or. 5 ° C, ° F degr ees Celsius, degrees Fah renheit 6 A amperes (amps) V, mV volts, millivolts μ F, nF microfarad, nanofarad DC AC Direct current or alternating current.
233 Getting Started Manual 8 Table 3. Input s 1 2 3 gcc110.eps No. Terminal Description 1 A Input for 0 A to 10.00 A current measurements. 2 COM Common terminal for all measurements. 3 Input for voltage, continuity, resistance, di ode, capacitance, tem perature, and frequenc y measurements.
True-rms Remote Display Digital Multimeter Features 9 Table 4. Funct ion Switch P ositions Sw it ch Position Description Hz (button) AC voltage from 0.06 to 1000 V. Frequency from 5 Hz to 50 kHz. DC voltage from 0.001 V to 1000 V. AC voltage from 6.
233 Getting Started Manual 10 Error Messages Table 5 contains possible error messages and the steps to clear the error. Table 5. Error Messages Error Messages Display-module batteries mu st be repl aced before the Meter will operate.
True-rms Remote Display Digital Multimeter Remote Operation 11 Remote Operation 2 1 gcc114.eps Figure 1. Display Module Separation 2 1 gcc115.eps Figure 2.
233 Getting Started Manual 12 Fuse Test Good fuse: 0.0 Ω to 0.5 Ω Replace fuse: OL gcc105.eps Figure 3. Fuse Test Battery Replacement 2 3 gcc111.eps Figure 4.
True-rms Remote Display Digital Multimeter Battery Replacement 13 2 1 3 4 gcc112.eps Figure 5. Meter Base Batter y Replacement.
233 Getting Started Manual 14 General Specifications Maximum voltage betw een any terminal and earth groun d ........................................... 1000 V rms W Fuse for A inputs ..................................................... 11 A, 1000 V 17000A interrupt ra ting Fuse Altitude Operating .
An important point after buying a device Fluke 233 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Fluke 233 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Fluke 233 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Fluke 233 you will learn all the available features of the product, as well as information on its operation. The information that you get Fluke 233 will certainly help you make a decision on the purchase.
If you already are a holder of Fluke 233, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Fluke 233.
However, one of the most important roles played by the user manual is to help in solving problems with Fluke 233. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Fluke 233 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center