Instruction/ maintenance manual of the product 1266-X Fisher
Go to page of 26
1266-X & 1266-XB Operating Manual Deep Search Metal Detector FISHER RESEARCH LABORATORY.
CONTENTS About Your 1266-X ................................................................. pg. 1 Condensed Operating Instructions ..................................... pg. 2 Setting Up ................................................................
ABOUT YOUR DETECTOR 1 The 1266-X was designed to excel in three ways: depth, discrimination and simplicity. It offers a better combination of these three characteristics than any other metal detector we’ve ever built. And we’ve been building metal detectors since 1931.
2 CONDENSED OPERATING INSTRUCTIONS The 1266-X is basically a turn-on-and-go metal detector. It doesn’t take an engineer to operate it but you’ll have more fun and a better chance of making that BIG find if you have a complete understanding of what you’re doing.
3 SETTING UP Your 1266-X is just about ready to use. The only adjustment required is the angle of the search coil and the length of the stem. Take a look at Figure 1 and familiarize yourself with the parts of the 1266-X before proceeding. 1. Unpack it carefully.
4 SETTING UP REMEMBER • THE LONGER THE SHAFT, THE MORE YOU WILL HAVE TO BEND YOUR ELBOW AND THE SOONER YOUR ARM WILL GET TIRED. THE 1266-X IS BALANCED FOR COMFORTABLE SEARCHING IN A TIGHT SEMICIRCLE AROUND THE FRONT OF THE OPERATOR. 6. With the stem length properly adjusted, tighten the lock nut and search coil wing nut.
5 1. DISC 1: DISCRIMINATE 1 is the search mode. The 1266-X automatically operates in DISC 1 unless the TRIGGER-SWITCH is pushed and held or pulled and held. DISC 1 is a full range discrimination mode. All types of metal are detected at the zero level and most small pieces of trash are rejected at the maximum level of ten.
or weak batteries will give no tone. Batteries do not have to be replaced as long as you can hear a tone. As a general rule, you’ll be able to operate your 1266-X for an hour or two after the tone goes silent. 6. OFF/VOL: Power on-off and volume control.
7 2. Pull the SENSITIVITY control out and turn full clockwise. (Back it off slightly if circuit noise is too loud or annoying in the full clockwise position.) 3. Turn the OFF/VOL control full clockwise. (If you’re wearing headphones reduce the volume to a comfortable level when the search coil is over a large target).
8 others. You have now determined the approximate discrimination points for the rejected objects. For example, the small nail discrimination point may be 4 and the pull-tab discrimination point 6. 7. Push and hold the TRIGGER-SWITCH. The 1266-X is now operating in the DISC 2 mode.
9 Take a look at the illustration above and note how the discrimination level (as well as sweep speed and ground mineralization) affects the search coil detection pattern. Not only is depth reduced at high discrimination levels but also the width of the pattern is reduced.
10 electrical interference caused by radio/TV stations, power lines, etc. Turn your sensitivity up if you want those deepest, smallest targets and you’re willing to put up with some background noise and more false signals. The maximum sensitivity position is with the knob pushed in and rotated full clockwise.
11 Figure 6. Keep the search coil parallel and as close to the ground at all times. important for maximum coverage and depth. 4. If you’re hunting on a lawn you can set the coil right on the grass and search. 5. Take your time and overlap your sweeps by at least 50%.
12 ZERO MOTION PINPOINTING MODE Target location is a snap using the Zero-Motion Pinpointing mode. You do not have to keep the coil moving to get a response in this mode. 1. Once the presence of a buried target is indicated by the “beep-beep” of the 1266-X, simply place the coil LIGHTLY on the ground, away from the target area.
13 TARGET RECOVERY Once you have pinpointed a target, your objective is to recover it quickly and neatly, leaving virtually no trace of your excavation.
14 OPERATING TIPS 1. We’ve already said it but it bears repeating: TAKE YOUR TIME AND OVERLAP YOUR SWEEPS. 2. Keep your discrimination levels set low.
15 ground mineralization, the higher the sensitivity loss. For example, you may be able to detect a penny 6 inches deep at zero discrimination, but no deeper than 4 inches at the pull tab discrimination point. Also, ground mineralization can reduce a detector’s ability to discriminate accurately.
16 FALSE SIGNALS Due to the extreme sensitivity of the 1266-X, you’re bound to get some “false signals” once in awhile. A false signal occurs when something that shouldn’t sounds like a good target.
17 the beeps or, if you sweep at right angles to your original direction, you’ll receive a single beep directly over the target (except for the very shallow coin). One way to tell the difference between a coin and a nail is to set your discrimination at about 5.
18 BATTERY RECHARGING Rechargeable nicad batteries may take as many as 1,000 recharges, however they do have some limitations you should be aware of: 1. Nicads will last only about half as long as standard carbon-zinc batteries before recharging is required.
19 batteries will eventually only hold a three-hour charge. 3. Nicads may reverse polarity if discharged too far and will not recharge. Don’t leave your detector on and don’t continue to operate it more than an hour after the battery check tone goes silent.
20 MAINTENANCE Your 1266-X doesn’t require a lot of care but there are a few things you should do to keep it in peak operating condition. 1. If you’re not going to be using it for a while, take the batteries out. Acid damage caused by leaking batteries can be severe.
21 Where To Use Your Metal Detector In The U.S. National Forest and Federal Lands —Metal detecting is allowed only by special permit acquired from the federal government.
22 SPECIFICATIONS Length 2 ......................... Extended ................................................ 54” Collapsed .............................................. 43” Carrying case ............... 6 x 15 x 21 inches Weight ...............
23 NOTES 1. Subject to modification or improvement without notice 2. Approximate 3. Pulsegate Unipolar Audio Processing-advanced Fisher circuitry that allows silent operation below the “Audio-Threshold Tone” with no sensitivity loss. 4. DISC 1 and DISC 2 are motion modes, i.
EXPORT DEPARTMENT P.O. Box 1896 New Haven, CT 06508 USA Tel 203.288.1638 Fax 203.287.8099 email: mb@exportdept.com FISHER RESEARCH LABORATORY 200 West Willmott Road., Los Banos, California 93635 Tel 209.826.3292 Fax 209.826.0416 www.fisherlab.com email:info@fisherlab.
An important point after buying a device Fisher 1266-X (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Fisher 1266-X yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Fisher 1266-X - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Fisher 1266-X you will learn all the available features of the product, as well as information on its operation. The information that you get Fisher 1266-X will certainly help you make a decision on the purchase.
If you already are a holder of Fisher 1266-X, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Fisher 1266-X.
However, one of the most important roles played by the user manual is to help in solving problems with Fisher 1266-X. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Fisher 1266-X along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center