3URJUDPPLQJ*XLGH ON OFF AR M E D R E A D Y A B C D 6 4 7 9 # 3 5 8 0 2 1 FA260 R A R M E D R E A D Y FA560 6 4 7 9 # 3 5 8 0 2 1 R AWAY STA Y P A G E K5305-5PRV2 10/03 Rev.
– 2 – TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad term inals on the control. A. PO WER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up (if ✱ 98 was used to exit program mode, this method m ust be used to reenter program mode).
– 3 – 352*5$00,1*)250 Entries apply to both the FA168CPS and FA148CP controls, except entries shown in dashed boxes, which apply only to the FA168CPS (partition entries) and are not applicable to the FA148CP . Entry of a number other than one specified will give unpredictable results.
– 4 – NOTE: Entry of a number other than one specifie d will give unpredic table re sults. For fields *43 thr u *46: Enter 0 – 9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ✱ ] as the fourth digit i f a 3-digit account number (for 3+1 dialer reporting format) is used.
– 5 – ✱ 65 OPEN REPORT CODE [0,0,0] S ee box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0 ,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previ ous page.
– 6 – ✱ 92 PHONE LINE MONITOR ENABLE UL: see Inst. Instru ctions for req uireme nts [0,0] 1 2 NOTE: Output Device must either be programmed to be STOPPED in fie ld ✱ 80 or STOPPED by Code + # + 8 + output number.
– 7 – MISCELLANEOUS SYSTEM FIELDS (*174-*181) ✱ 174 CLEAN ME REPORTING OPTIONS (for ESL s moke det ectors ) [0] 0 = disabl e; 1 = Clean Me s ignal reports ; Note: If Clean M e is enabled, you must enter “ 3 ” in field ✱ 56 program ming for z one 1 response t ime.
– 8 – Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed v ia downloader software or from a keypad us ing data fields*182-*185. Configurable z one types 92 and 93 (F A168CPS only) c an only be programmed us ing the downloader software.
– 9 – *56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardw ire Type Rsp.
– 10 – *57 FUNCTION KEY PROGRAMMING Option Function A B C D Comments 01 Paging 02 Time Disp lay 03 Arm AWAY 04 Arm STAY 05 Arm NIGHT-STAY 06 Step Armi ng 07 Device Activation Device: 08 Comm.
– 11 – ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation m anual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in * 79, *80, and *81 modes.
– 12 – Zone Type Definitions Type 00 Zone Not Used Use this zone ty pe if the z one is not used. Type 01 Entry/Exit Burglary #1 • Assi gn to zones that are us ed for primary entry and ex it. • Provides entry delay if the c ontrol is armed in t he Away or St ay modes .
– 13 – Type 21 Arm-Away • Arms th e system in Aw ay mode w hen the zone is ac tivat ed. • Pushbutton unit s send t he user number t o the cent ral stat ion when arming or dis arming. • User code for butt on must be assigned. Type 22 Disarm • Di sarms th e system w hen the zone is acti vated.
– 14 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors) 000 (Word Space) – A – • 001 AIR • 002 ALARM ∗ 004 A LLEY 005 AMBUSH • 006 AREA • 007 APARTM ENT • 009 ATTIC ∗ 010 A .
– 15 – 5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
CLASS 2 PLUG-IN TRANSFORMER 16.5V AC, 25V A (e.g. 1321). (USE No. 1321CN IN CANADA) TO 110V AC UNSWITCHED OUTLET (24HR) THIS EQUIPMENT SHOULD BE INST ALLED IN ACCORD ANCE WITH THE NA TIONAL FIRE PROTECTION ASSOCIA TION'S ST ANDARD 72, CHAPTER 2 (NA TIONAL FIRE PROTECTION ASSOCIA TION, BA TTERY - MARCH P ARK, QUINCY ,MA 02269).
An important point after buying a device First Alert FA168CPS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought First Alert FA168CPS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data First Alert FA168CPS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, First Alert FA168CPS you will learn all the available features of the product, as well as information on its operation. The information that you get First Alert FA168CPS will certainly help you make a decision on the purchase.
If you already are a holder of First Alert FA168CPS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime First Alert FA168CPS.
However, one of the most important roles played by the user manual is to help in solving problems with First Alert FA168CPS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device First Alert FA168CPS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center