OWNER'S OPERA TING MANUAL Hardwire Uninterruptible Power Supply Models: SG2K-1T -HW SG2K-2T -HW SG3K-1T -HW SG3K-2T -HW Det ailed SG Series product specifications are available in PDF format at www .falconup s.com F ALCON ® Electric Inc., 5106 Azusa Canyon Rd.
SG UPS Features. ...... 1 SG Series Online UPS Block Diagram. .... 1 Import ant Safety Instructions (READ FIRST) .... 2 Chapter 1. SG Series UPS Overview ..... 3 T rue Regenerative Online Design .... 3 Input Power Factor Correction .... 3 Microprocessor Control .
SG SERIES UPS FEA TURES SG SERIES ON-LINE UPS SYSTEM BLOCK DIAGRAM Hardwire Input and Output Conneciton T rue Double Conversion On-Line Design Input Power Factor Correction Wide Input V olt age Window.
IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual contains import ant instructions which must be followed during the installation, operation and maintenance of this UPS and its batteries. Please read all instructions before operating this equipment and save this manual for future reference.
CHAPTER CHAPTER 1 1 SG Series UPS - Overview General - Common for all models 1. V erify the following is included in the UPS shipping carton: (1) UPS, (1) Software Diskette(s) & Manual, (1) Owners Manual & (1) UPS/Computer Cable. 2. V erify the UPS unit is configured for the proper input/output voltage and frequency .
5. Select a suitable location for the UPS. VERIFY THE FLOOR OR SURF ACE SUPPORTING THE UPS WILL SUPPORT THE WEIGHT OF THE UPS AND ANY OPTIONAL EXTENDED BA TTER Y BANKS. SG2K-2T -HW & SG2K-2T -HW UPS MODELS = 68.4 lbs. (31 kg) SG3K-2T -HW & SG3K-2-HW UPS MODELS = 81.
DIP SWITCHES SELECTION TABLE ON = 1 OFF = 0 SW2 SW1 OUTPUT VOLTAGE 1 (All models) OUTPUT VOLTAGE 2 (- TX & - TXC models only) Down Down 208 Vac 115 Vac Down Up 220 Vac (default) 120 Vac Up Down 23.
1.0 UPS Input & Output Requirement s. Note: All SG Series hardwire UPS models must be installed by a licensed electrician, in accordance with the National Electrical Code (NEC) ANSI/NFP A70 and all local regulations.
1.1 UPS Output Requirement s Note: The output s of the SG2K-2T -HW & SG3K-2T -HW hardwire models are not configured for 240/120V ac split-phase operation. Should a 240/120V ac split-phase output configuration be required, please cont act the factory .
2.0 UPS ST ARTUP 1. V erify the following is included in the UPS shipping carton: (1) UPS, (1) Software Diskette(s) & Manual, (1) Owners Manual & (1) UPS/Computer Cable. 2. V erify the UPS unit is configured for the proper input/output voltage and frequency .
5. Select a suitable location for the UPS near enough to the computer or equipment to to be protected. Connect the power cord(s) for the equipment to be protected to the UPS output receptacles. VERIFY THE T ABLE OR SURF ACE SUPPORTING THE UPS WILL SUPPORT THE WEIGHT OF THE UPS AND ANY OPTIONAL EXTENDED BA TTER Y BANKS.
TYPICAL EXTENDED BA TTER Y BANK & UPS INTERCONNECTION (Mini-tower models shown; same applies for floor st anding banks) INST ALLA TION PROCEDURE FOR EXTENDED BA TTER Y BANKS 1. Remove the battery fuse located on the UPS rear panel. See illustration above.
SG 2-3kV A T OWER EXTENDED BA TTER Y BANK SELECTION GUIDE BATTERY OPTI ON MOD ELS W/O C ha r ge r SGB2S7-2 K3 SGB2S7-2 K3 SGB5S7-2 K6 SGB2S7-2 K3 SGB5S7-2 K6 SGB5S7-2 K6 BA TTERIES 12 Pieces of 12V, 7.
12 CHAPTER CHAPTER 3 3 OPERA TION 1 2 3 4 5 6 7 8 9 10 11 UPS FRONT P ANEL INDICA TOR AND FUNCTION KEYS 1. LOAD LEVEL INDICA T OR LEDS *The first or bottom LED is lit when the output load is greater than 25% of the rated output of the UPS. *The second LED is lit when the output load is greater than 50% of the rated output of the UPS.
5. BYP ASS INDICA T OR LED When this LED is lit the UPS bypass is active. Should the Alarm LED be lit at the same time, the UPS detected an internal failure and the UPS must be serviced. 6. INVERTER INDICA T OR LED When this LED is lit, the UPS inverter is operating and powering the connected load.
AUDIBLE ALARMS Audible alarm signals are divided into two different levels of alarm st atus. Category one alarms represent normal or correctable operational alarms. Category two alarms are sounded in the event of abnormal operation. 1. Category one alarms : a.
Dip Sw itc hes Batter y fuse as rece ived in bag . At the time of initial i nstallat ion re move the bag from t h e unit and inst all th e batt ery fu se Ba ttery Fus e Hold er Prio r to in sta llin g th e batt ery fu se, depress th is button of one second to pre-charge the UPS and imme dia tely in stall th e b att ery fus e.
CHAPTER CHAPTER 5 5 COMMUNICA TIONS INTERF ACES RS-232 INTERF ACE 16 P in # Function explan ation I/O 9 RS 232 Rx INP U T 6 RS 232 Tx OUT P UT 7 Gr ound Location: The RS-232 interface is standard on all SG series UPS models. The port is located on the UPS rear panel, via a DB-9 female connector .
17 DR Y CONT ACT & OPTO COUPLER INTERF ACE BOARD OPTIONS JP1 JP2 JP3 J1 J2 J3 DB- 9 T ypical Falcon Dry Contact Relay Board PIN DESCRIP TION 1 Low Battery ( When UPS reaches low battery, c ontact acti vates) (J1, 1-2 short = N.O) (J1, 2-3 short = N.
18 PIN ASSIGNMENT FOR THE F ALCON UA88373 OPTO-COUPLER OPTION BOARD (no-byp ass signal) PIN DESCRI PTIO N 1 Not Used 2 Uti lity Los s (N .O.) (C los es upon ut i li ty l oss ) 3 Utili t y Los s (N.C. ) (O pens upon util it y loss) 4 Comm on for pins 2, 3 & 5 5 Lo w Batter y (N .
APC Style Dry Cont act Relay Board PIN DESCRIPTION 1 Remote Shutdown (on battery operation only) 2 Remote Shut down Common 3 Not Used 4 Low Ba ttery Co mmon 5 Low Battery (N.
CHAPTER CHAPTER 6 6 Maintenance & T echnical Support 1. Care & Maintenance Falcon ® SG Series UPSs are designed to be maintenance-free. They can be cleaned with a damp cloth or non-abrasive cleanser , providing the UPS is turned off and the input plug is disconnected from the utility source.
The following precautions should be observed by a qualified technician when working with batteries. 1. Remove watches, rings, or other metal object s. 2. Use tools with insulated handles. 3. Wear rubber gloves and boot s. 4. Do not lay tools or metal p arts on top of batteries.
6. T echnical Support Should your F ALCON ® Electric SG Series UPS require service or you need technical assistance, you can cont act us at: Falcon Electric Inc. 5106 Azusa Canyon Road Irwindale, CA. 91706 Service 800.842.6940 V oice 626.962.7770 Fax 626.
GENERAL PROVISIONS F ALCON® ELECTRIC INC., hereby warrants product shipped under this agreement to be free from defective workmanship for a period of two years following date of shipment. This Limited New Product W arranty Agreement only applies to covered rep airs to the product occurring within the United S tates and Canada.
SG Series TM UPS PLUS ® 2kVA & 3kVA 24 Electrical Input Nominal AC Voltage 120V 230V 120V 230V 230V AC Voltage Range 87 – 140V 170 – 275V 87 – 140V 170 – 275V 170 – 275V Current – Am ps 14.2 7.4 21.4 11.2 7.5 11.3 Frequency 50/60 Hz ± 5% (A uto – T racking) Power Factor Correction > 0.
An important point after buying a device Falcon SG3K-2T-HW (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Falcon SG3K-2T-HW yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Falcon SG3K-2T-HW - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Falcon SG3K-2T-HW you will learn all the available features of the product, as well as information on its operation. The information that you get Falcon SG3K-2T-HW will certainly help you make a decision on the purchase.
If you already are a holder of Falcon SG3K-2T-HW, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Falcon SG3K-2T-HW.
However, one of the most important roles played by the user manual is to help in solving problems with Falcon SG3K-2T-HW. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Falcon SG3K-2T-HW along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center