613-001443 Rev A Management Software Layer 2-4 Gigabit Ethernet EcoSwitches AT-9000/28 AT-9000/28SP AT-9000/52 ◆ Web Browser User’s Guide AlliedWare Plus Version 2.
Copyright Copyright © 2010, Allied T elesis, Inc. All rights reserved. This product includes software licensed under the BSD Licen se. As such, the follow ing language applies for th ose portions of .
Allied Telesis is committed to meeting the requirements of the open source licenses incl uding the GNU General Public License (GPL) and will make all re quired source code available.
.
5 Contents Preface ........ ................ ............. ................ ................ ............. ................. ................ ............ ............. ................ 11 Document Conventions ................ ................. ......
Contents 6 Displaying the Storm Control Settings .................... ................... ................ ................ ................... ....... ............. 66 Modifying the Storm Control Settings ..... ................ ................ .....
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 7 Chapter 12: Se tting Switch Spanning Tree Protocols .................. ................ ................. ............ .............. 137 Overview .......... ............
Contents 8 Creating an ELIN Location ..... .......... ............. ................ ................ ............. ................ ............. ............. .... 207 Configuring LLDP and LLDP-MED ..... ................. ................... .......
9 Figur es Figure 1: Login Menu .................... .......................................... .................................... ......... .. .......................... ..................... 20 Figure 2: Displaying the IP address .................
Figures 10 Figure 51: IGMP Snooping Page with Hosts List Tab ...... .................................................. ...................... ...... .............. .......153 Figure 52: Security Tab.... ......................... .............. .......
11 Pr eface This is the web browser management guide for the AT-9000/28, AT-9000/ 28SP, and AT-9000/52 Managed L ayer 2-4 Gigabit Ethernet EcoSwitches. The instructions in this guide exp lai n how to start a management session, use the web interface of the Alli edWare Plus™ Management Software, and configure the features of the switch.
Preface 12 Document Conventions This document uses the following conventions: Note Notes provide additional informatio n. Caution Cautions inform you t hat performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a sp ecific action may result in bodily injury.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 13 Downloading Management So ftware and Web-based Guides Both new releases of managemen t soft ware and product documentation are available from t he Allied Telesis web site s.
Preface 14 Contacting Allied Telesis This section provides Allied Telesis contact information for technical support and for sales and corporate informa tion. Online Support You can request technical sup port online by accessing the Allied Telesis Knowledge Base: www.
15 Chapter 1 AlliedW ar e Plus™ V ersion 2.1.2 W eb Br owser Interface This chapter describes the types of web management sessions on the AlliedWare Plus web interface and the web interface manag er accounts.
Chapter 1: Allie dWare Plus™ Version 2.1 .2 Web Browser Interf ace 16 Management Sessions This manual provides procedures that guide you through the AlliedWare Plus Web interface.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 17 Web Manager Accounts You must log on to manage the switch. This requires a valid username and password. The switch comes with one web manager account with a username of “manager” and the default password of “friend.
Chapter 1: Allie dWare Plus™ Version 2.1 .2 Web Browser Interf ace 18.
19 Chapter 2 S tarting a Management Session This chapter describes how to sta r t a management session using the AlliedWare Plus web interface as well as how to se lect fields, save your changes, and end a management session.
Chapter 2: St arting a Management Session 20 Starting a Web Management Session Before you start a remote web ma nagement session, you must log on to the AlliedWare Plus CLI and assign an IP address to the switch. Also, you must enable web management on t he switch which is disabled by default.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 21 5. Display the IP address assigned to VLAN 1 by entering th e following commands: awplus(confi g-if)# exit awplus(confi g)# exit awplus# show ip interf ace For a display of this command, se e Figure 2.
Chapter 2: St arting a Management Session 22 The Login Page is displayed. Se e Figure 3. Figure 3. Login Page 9. Enter “manager” in the User Name field and “friend” in the Password field.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 23 The Dashboard p age is displayed. See Figure 4. The Dashboard p age is the home pa ge of the switch.
Chapter 2: St arting a Management Session 24 MAC Address — Specifies the MAC address of the switch. IPv4 Address — Displays the IPv4 address and subnet mask of the web interface. The IPv4 management add ress is assigned to the switch. The address is specified in the following f ormat: xxx.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 25 IPv6 Gateway — Displays the IPv6 address of the next hop of the switch’s default route. The switch uses a default route when it must communicate with a device that is not on the local IPv6 network.
Chapter 2: St arting a Management Session 26 Selecting items from a Web Page To select a feature or parameter, place your curso r over the selection an d wait for it to turn orange.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 27 What to Configure First Here are a few suggestions on what to configure during your web management session on the switch. The initial management session must be a local management session fro m the Console port on the switch.
Chapter 2: St arting a Management Session 28 Saving Your Changes In the web interface, there are two ways to save your changes. After you complete a procedure, click Apply as shown on the System Contact Information page. See Figure 5. This saves the information to the running configuration file.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 29 Ending a Web Management Session To end a web manageme nt session, select LOGOUT at th e top of the web page. For an example, see the System Co ntact Information page in Figure 5 on page 28.
Chapter 2: St arting a Management Session 30.
31 Chapter 3 Basic Switch Parameters This chapter describes how to se t up ba sic switch operations in the web interface. See the following sections: “Setting the System Date and T ime” on p a.
Chapter 3: Basic Switch Parameters 32 Setting the System Date and Time This procedure explains how to set the switch’s date and time. Setting th e date and time is important if you plan t o view the events in the switch’s event log or send the events to a sy slog server.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 33 Setting System Time Manually To set the system time manually, do the following : 1. Select the System tab. 2. From the System tab, select System Settings . The System Settings T ab is displayed in Figure 6.
Chapter 3: Basic Switch Parameters 34 Figure 7. System Time Settings Page 4. There are two ways to set the date and time manually. Use eith er step 4 or step 5. To type in the system date and time in the Date & Time field, do the following: a. Enter the time and date in the follo wing format: yyyy-dd-mm hh:mm:ss b.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 35 d. Close the Calendar page. See Figure 8. Figure 8. Calendar Page 6. Enter the time at the bottom of the page in the hh:mm:ss format. 7. Click Apply Setting An SNTP or NTP Server To configure SNTP or NTP server, do the following: 1.
Chapter 3: Basic Switch Parameters 36 Figure 9. System Time Settings Page with Network Time Se ttings Tab 5. To configure the switch to obtain its date and time from an SNTP or NTP server on your network or the Internet, configure the following fields: NTP Status — Enables o r disables the SNTP client on the switch.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 37 Note The switch does not set DST a u tomatically. If the switch is in a locale that uses DST, you must remember to en able this in April when DST begins and disable it in October when DST ends.
Chapter 3: Basic Switch Parameters 38 Setting a Telnet or SSH Server The AlliedW are Plus Web Browser interface allows you to co nfigure the switch as a T elnet or SSH server . You can use the web browser interf ace to enable a Telnet server, but not as a Telnet client.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 39 The System Services p age is displayed. See Figure 10. Figure 10. System Services Page 3. Configure the following parameters as necessa ry: Telnet — Selecting this field enables a Telnet server on the switch.
Chapter 3: Basic Switch Parameters 40 Setting a Remote Log Server You can use the AlliedWare Plus Web browser interface to assign the switch to a remote log server which is part of the Syslog feature. However, you must use the CLI to view or clear the event log.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 41 Setting the Switch Information This procedure allows you to set info rmatio n about the switch such as a switch name, contact, and locat i on.
Chapter 3: Basic Switch Parameters 42 Change the following p arameters as necessary: System Name — Specifies a name fo r the switch (for example, Sales Ethernet switch). The name is displayed o n ly on the Dashboard page. The name can be from 1 to 39 characters in length.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 43 Setting the Configuration File Within the web browser interface, you can upload a configuration f ile on to the switch, download a con figuration file from the switch, or delete a configuration file.
Chapter 3: Basic Switch Parameters 44 The following fields are displayed: Startup Config — Displays the name of the active boot configuration file, which for the switch in the example is “boot.cfg.” File Name — Indicates the name of the configuration files.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 45 Managing User Accounts The procedures in this section describe how to create user accounts as well as change passwords and privile ges. There is a l so a procedure that describes how to delete a us er account.
Chapter 3: Basic Switch Parameters 46 3. Enter a name in the Us er Name field. This field specifies the log on nam e for the new account. The name is case sensitive and can cont ain up to fifteen alphanumeric characters. S paces and special characters are not allowed.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 47 Figure 15. User Management Pa ge with Change Password Tab 4. Use the pull-down menu next to the User Name field to select the user name. The user name must already exist.
Chapter 3: Basic Switch Parameters 48 Changing the User Privilege To change a privilege of a use r, do the following: 1. From the home page, click the System tab. The System Settings T ab is displayed. See Figure 6 on page 33. 2. From the System Settings t ab, select User Management .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 49 Level 1: Management accounts with a u s er level of 1 have restricted access to the switch. 6. Click Set Priv ilege . 7. Click SAV E to save your changes to the start-u p configuration file.
Chapter 3: Basic Switch Parameters 50 Rebooting a Switch Resetting the switch ends your web browser management session . T o continue managing the switch, you must login again. Note All unsaved changes are discarde d when you re set a switch. To save your changes, click SAVE on the home page.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 51 Upgrading the Software You can obtain the latest version of the AlliedWa re Plus software from th e Allied Telesis web site. You must have access to a TFTP server from you r PC to upgrade the AlliedWare Plus software on your switch.
Chapter 3: Basic Switch Parameters 52 Figure 18. System Upgrade Page 5. Click Browse to select an image file. 6. Click Open to select a file. 7. Click Start Upgrade to begin the software upgrad e or Cancel to cancel the procedure.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 53 Returning the AlliedWare Plus Mana gement Software to the Factory Default Values To reset the AlliedWare Plus Management Sof tware parameters to their default values, you must use the Command Line Interface.
Chapter 3: Basic Switch Parameters 54 Displaying System Information To view basic information about the switch, do the followin g: 1. Select the System Tab.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 55 System Contact — Indicates the contact person f or the switch. To configure this field, see “Setting the Switch Info rmation” on page 41. System Location — Indicates the location of the switch.
Chapter 3: Basic Switch Parameters 56 The Administration Options section displays the following information: System Upgrade — Select this field to upgrade your system software. See “Upgrading the Software” on pa ge 51. Reboot — Select this field to rebo ot the switch.
57 Chapter 4 Setting Port Parameters This chapter describes how to display and modify the port settings such as back pressure and flow control. In addition, it provide s procedures to display and modify storm control settings.
Chapter 4: Settin g Port Parameters 58 Displaying the Port Parameters The port numbering system in the AlliedWare Plu s web browser interface is different from the port numbering system in the CLI . For an example of the port numbering equivalents for the first five ports, see Table 1.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 59 2. From the Switching tab, select Po rt . The Port tab exp ands to the right. 3. From the Port tab, select Port Configu r ation . The Port Configuration page is d i splayed.
Chapter 4: Settin g Port Parameters 60 4. The following fields are displayed: Port — Indicates the port number. Type — Specifies the if the port is fiber, indicated by 1000-FX, or copper, indicated by 100-FX. Status — Indicates if the port is enabled o r disabled.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 61 packet congestion. In addition the po rt continues transmitting packets when it receives pause pac kets from its local o r remote counterpart. The default is “Disabled.
Chapter 4: Settin g Port Parameters 62 Changing the Port Settings You can change th e settings of one por t at a time. Use the following procedure to change the port settings o r reset a port to its default value, To change the port settings, do the following : 1.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 63 Figure 21. Port Configuratio n Modify Page 5. Configure the following parameters as needed: Port — Indicates the port number. Port Type — Indicates the type of port, fiber or copper.
Chapter 4: Settin g Port Parameters 64 from white to brown and you cannot se lect them. To change the Speed and Duplex Mode fields, change the Nego tiation setting to “Manual.” Speed — Indicates th e port speed. Select 10mb, 100mb, or 1000mb.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 65 Flow Control Limit (1 - 7935) — Indicates th e threshold levels for flow control on the ports. Specifies the number of cells for flow control. A cell represents 128 bytes.
Chapter 4: Settin g Port Parameters 66 Displaying the Storm Control Settings To display the storm control settings, do the following : 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select Port .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 67 Multicast Level — Specifies the maximum number of ingress packets per second of multicast packets the port will forward. The range is 0 to 33,554,431 packets. T he default is 33,554,431 packets.
Chapter 4: Settin g Port Parameters 68 Modifying the Storm Control Settings To modify the storm control settings, do the following: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select Port .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 69 5. Change the following fields as needed: Port Number — Indicates the port number. Broadcast — Indicates Broadcast packets are received, indicated by “ON,” or not received, indi cated by “OFF,” by the port.
Chapter 4: Settin g Port Parameters 70.
71 Chapter 5 Setting Port S tatistics This chapter describes how to displa y and clear port statistics. Within the AlliedWare Plus software, you can disp lay a nd clear transmit, receive, and interface port statistics.
Chapter 5: Se tting Port Statistic s 72 Displaying Port Statistics You can display several types of port st atistics. See the following sections: “Displaying T ransmit and Receive Port S t atist.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 73 The following fields are displayed: Port — Indicates the port number. 0-64 Byte Frames — The numb er of frames transmitted by the port that contain 0 to 64 bytes.
Chapter 5: Se tting Port Statistic s 74 Figure 25. Port Statistics with th e Receive Tab The following fields are displayed: Port — Indicates the port number. Total Bytes — Indicates the number of received bytes. Total Frames — Indicates the number of received frames.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 75 Fragmented Frames — Indicates the number of u ndersized frames, frames with alignment erro rs, and fra mes with frame check sequence (FCS) errors (CRC errors).
Chapter 5: Se tting Port Statistic s 76 The Port S tatistics wit h the T ransmit tab selected is displayed. See Figure 26. Figure 26. Port Statistics with the Transmit Ta b The following fields are displayed: Port — Indicates the port number. Total Bytes — Indicates the number of transmitted bytes.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 77 Total Collision Frames — Indica tes the total numb er of collisions on the port. MAC Error Frames — Indicates the number of frames not transmitted correctly or dropped due to a n internal MAC transmit error .
Chapter 5: Se tting Port Statistic s 78 Rx Discard Packets — Indicate s the number of ingress packets that were discarded prior to transmission because of an error . Rx IP Header Error Packets — In dicates the number of ingress packet s that were discarded because of a hardware error .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 79 Clearing Port Statistics To clear the statistics for a port, do th e following: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58. 2.
Chapter 5: Se tting Port Statistic s 80.
Chapter 6 Setting Port Mirr oring The port mirror is a management tool that allows you to monitor the traffic on one or more ports on the switch. It works by copying the traffic from designated ports to another port where the traffic can be monitored with a network analyzer.
Chapter 6: Settin g Port Mirroring 82 Overview To use the port mirroring feature, yo u must designa te on e or more source ports and one destination port.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 83 Displaying Port Mirroring Settings To display the port mirroring assign ments for all of the switch ports, do the following: 1. Select the Switching tab. The Switching tab is displaye d.
Chapter 6: Settin g Port Mirroring 84 Mirror Receive — Indicates a source port whose received, or ingress, packets are mirrored and monitored. There can be multiple source po rts on the switch.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 85 Assigning a Destination Port The destination port is the source port where the information from the mirror transmit and mirror receive por ts is copied. You must assign the destination port before the mirror tr ansmit and mirror receive ports.
Chapter 6: Settin g Port Mirroring 86 Assigning Port Mirroring Values To assign mirrored ports and mirroring ports, do the following: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select Port .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 87 5. Select the type of mirroring for the port. The choices are: None — Specifies the port is not a source port. Send — Specifies the port is a t ransmitting, or egress, source port.
Chapter 6: Settin g Port Mirroring 88.
89 Chapter 7 Setting the Port Spanning T r ee Pr otocol The Spanning Tree Protocol (STP) a nd the Rapid Spanning Tre e Protocol (RSTP) guard against the formation of loops in an Etherne t network topology. A topology has a loop when two or more nodes can tra nsmit packets to each other over more than one data path.
Chapter 7: Settin g the Port Spanning Tree Pro tocol 90 Overview STP and RSTP prevent loops from form ing by ensuring that on ly one path exists between the end nodes in your network. Where multiple paths exist, these protocols place the extra paths in a standby or b locking mode.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 91 Displaying Port Spanning Tree Protocol Settings To display the Spanning Tree Prot ocol settings for all of the switch ports, do the following: 1. Select the Switching tab.
Chapter 7: Settin g the Port Spanning Tree Pro tocol 92 domain becomes the root bridg e. If two or more devices have the same priority value, the device with the numerically lowe st MAC address becomes the root bridge. Version — Indicate s the Spanning Tree Protocol version.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 93 Modifying Port Spanning Tree Protocol Settings To modify port settings for Spannin g Tree Protocol, do the following: 1. Select the Switching tab. The Switching tab is displaye d.
Chapter 7: Settin g the Port Spanning Tree Pro tocol 94 Path Cost (1-200000000) — Use this field to specify the cost of a port to the root bridge. This cost is comb ined with the costs of the other ports in the p ath to the root bridge, to determine the total path cost.
95 Chapter 8 Setting the MAC Addr ess The procedures in this chapter descr ibe ho w to display the MAC address table that resides on the switch as well as h ow to add an unicast or multicast MAC addresses to the table. Pro c edures to modify and delete MAC addresses within the table are also included in this chapter .
Chapter 8: Settin g the MAC Address 96 Displaying the MAC Address You can display both the u nicast and multicast addresses in the MAC address table. See the fo llowing procedures: “Displaying t.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 97 Figure 33. Unicast MACs Page The following fields are displayed: MAC Address — Indicates the dynamic or static u nicast MAC address learned on or assigned to the port.
Chapter 8: Settin g the MAC Address 98 Figure 34. Multicast MACs Page The following fields are displayed: MAC Address — Indicates the dynamic or st atic unicast MAC address learned on or assigned to the port. Vlan — Specifies the ID numb er of the VLAN where the multicast application and the host nodes are members.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 99 Assigning a MAC Address You can assign a new unicast or mu lticast MAC address to the MAC address table.
Chapter 8: Settin g the MAC Address 100 5. Select a port number with the Port Number pull-down menu. Y ou can only assign one port nu mber to a unicast MAC address. 6. Select a VLAN with the Vlan pull-down menu . For a unicast address, this field specifies the name of the VLAN wh ere the node designated by the MAC address is a member .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 101 4. To assign a MAC Address, enter a multica s t MAC address in the Mac Address field. Use the follow ing format: xx:xx:xx:xx:xx:xx 5. Select a port list with the Port L ist pull-down menu.
Chapter 8: Settin g the MAC Address 102 Deleting a MAC Address To delete a MAC address from the MAC ad dress table, see the following procedures: “Deleting a Unicast Address” on p age 102 .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 103 To delete a specific MAC address, click Delete next to the MAC address that you want to delete.
Chapter 8: Settin g the MAC Address 104.
105 Chapter 9 Setting LACP The Link Aggregation Control Protocol (LACP) is use d to increase the bandwidth between the switch and oth e r LACP-compatible devices by grouping ports together to form single virtual lin ks. This chapter provides a brief descripti on of LACP and explains how to display and set LACP.
Chapter 9: Settin g LACP 106 Overview LACP trunks are similar in function to static port trunks, but they are more flexible. The implementations of static trunks tend to be vendor specific and so may not always be compatible. In co ntrast, the implementation of LACP in the switch is compliant with the IEEE 802.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 107 Displaying LACP Trunks To display the LACP trunk assignments f or all of the switch ports, do the following: 1. Select the Switching tab. The Switching tab is displaye d.
Chapter 9: Settin g LACP 108 4. The following fields are displayed: Aggregator ID — Each aggreg ator must have an ID number. The ID number is the base port number (or lowest number) of an aggregator. For instance, an aggregator of ports 12,16 and 17 must be assigned the ID number 12 because that is the base po rt.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 109 Adding an LACP Trunk To create an LACP trunk, do the following: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58. 2. From the Switching tab, select Link Aggregation .
Chapter 9: Settin g LACP 110 5. Select the Load Balance Method. Choo se from the following: Src MAC — Specifies sou rce MAC address as the load distribution method. Dst MAC — Specifies destination MAC address. Src-Dst MAC — Sp ecifies source address/destination MAC address.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 111 Modifying an LACP Trunk To modify the LACP Trunk setti ngs, see the f ollowing procedure: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58.
Chapter 9: Settin g LACP 112 5. Select the Load Balance Method. Choo se from the following: Src MAC — Specifies sou rce MAC address as the load distribution method. Dst MAC — Specifies destination MAC address. Src-Dst MAC — Sp ecifies source address/destination MAC address.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 113 Deleting an LACP Trunk To delete an LACP trunk, do the fo llowing: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58. 2. From the Switching tab, select Link Aggregation .
Chapter 9: Settin g LACP 114.
115 Chapter 10 Setting S tatic Port T runks Static port trunks are groups of two to eight ports that act as single virtual links between the switch and other network devices.
Chapter 10: Setting Sta tic Port Trunks 116 Overview Static port trunks are commonly used to improve ne two rk performance by increasing the available bandwidt h between the switch and other network devices as well as to enhance th e reli ability of the connections between network devices.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 117 Displaying Static Trunk Settings To display the static port trunks for all o f the switch ports, do the following: 1. Select the Switching tab. The Switching tab is displaye d.
Chapter 10: Setting Sta tic Port Trunks 118 The following fields are displayed: Trunk ID — Indicates the ID of the static tr unk. This na me must be the lowest port number appended with “sa.” For example, the trunk ID of “sa5” indicates a trunk with port 5 as the lowest port number in the trunk.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 119 Adding Static Trunks Review the following information bef ore creating a new static port trunk: When you create a new trunk, the settings o f the lowest numbered port are copied to the other port s so that all the ports have the same settings.
Chapter 10: Setting Sta tic Port Trunks 120 The Add S tatic T runk p age is displayed. See Figure 43. Figure 43. Add Static Trunk Page 5. Select the Load Balance Me thod . You can assign different load distribution methods to different static trunks on the same switch.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 121 6. Select the Member Ports by clickin g the box next to the port. A green check mark indicates a port has been selected.
Chapter 10: Setting Sta tic Port Trunks 122 Modifying the Static Trunk Settings Review the following info rmation if you are adding ports to an existin g trunk: If the port you are adding is the lowest numb ered port in the trunk, it s parameter set tings overwrites the settings of the existing ports in the trunk.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 123 The Modify S t atic Trunk page is displa yed. See Figure 44. Figure 44. Modify Static Trunk Page 5. Select the Load Balance Method . You ca n assign different load distribution methods to different st atic tru nks on the same switch.
Chapter 10: Setting Sta tic Port Trunks 124 6. Select the member ports that you wa nt to add to or remove from the static trunk by clicking on the ports. Caution To prevent the formation of network loops in your ne twork top ology, do not remove ports from a static po rt trunk without first disconnecting their network cable.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 125 Deleting Static Trunks To delete a static port trunk, do the following: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58. 2. From the Switching tab, select Link Aggregation .
Chapter 10: Setting Sta tic Port Trunks 126.
127 Chapter 11 Setting Port-based and T agged VLANs This chapter provides a brief descripti on of VLANs and explains how to display, create, and modify port-ba sed and t agged Virtual LANs which are more commonly known as VLANs.
Chapter 11: Setting Po rt-based and Tagged VLANs 128 Overview A VLAN is a group of ports that form a logical Ethernet segment on an Ethernet switch. The ports of a VL AN form an independent traffic domain in which the traffic generated by the nod es remains within the VLAN.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 129 The VLAN information within an Ethernet fr ame is referred to as a tag or tagged header . A tag, which fo llows the source and destination addresses in a frame, contains the VID of the VLAN to which the frame belongs (IEEE 802.
Chapter 11: Setting Po rt-based and Tagged VLANs 130 Displaying VLANs To display the VLAN assignments for all of the switch ports, do th e following: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select Virtual LANs .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 131 If a VLAN is unique in your network, then its name must be unique as well. A VLAN that spans multiple switches must have th e same name on each switch. Untagged Member Ports — Indicates which po rts are untagged ports.
Chapter 11: Setting Po rt-based and Tagged VLANs 132 Adding an VLAN To create an VLAN, do the following: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select Virtual LANs . The Virtual LANs p age is displayed.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 133 that spans three switches, assign the Sales VLAN on each switch the a VID value of 3. VLAN Name — Specifies a name of a VLAN. A name can be from 1 to 20 characters in length.
Chapter 11: Setting Po rt-based and Tagged VLANs 134 Modifying VLANs To modify the LACP Trunk settings, see the following procedure: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select Virtual LANs .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 135 4. Change the following fields as needed: VLAN Name — Specifies a name of a VLAN. A name can be from 1 to 20 characters in length. The firs t character must b e a letter; it cannot be a number.
Chapter 11: Setting Po rt-based and Tagged VLANs 136 Deleting VLANs To delete an VLAN, do the following: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select Virtual LANs . For an example of the V irtual LANs page is displayed, see Figure 45 on page 130.
137 Chapter 12 Setting Switch Spanning T r ee Pr otocols This chapter provides a brief description of both the Spannin g Tree Protocol (STP) and Rapid Spanning Tr ee Protocol ( R STP) and explains how to set the spanning tree protoc ols on t he switch.
Chapter 12: Setting Switc h Spanning Tree Prot ocols 138 Overview Both STP and RSTP guard against the formation of loops in an Ethernet network topology. A topology has a loop when two o r more nodes can transmit packets to each other over more than one data path.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 139 Displaying Switch Spanning Tree Protocol Settings To display the switch Spanning Tree Protocol settin g s do the following: 1. Select the Switching tab. The Switching tab is displaye d.
Chapter 12: Setting Switc h Spanning Tree Prot ocols 140 New Priority (0-15) — Assigns the switch a priority number. The device that has the lowest priority number in the spanning tree domain becomes the root bridg e.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 141 Max Age — Determines how long bridge protocol d ata unit s (BPDUs) are stored by the switch before they a re deleted. BPDU Guard — Enables the BPDU loop-guard feature on the switch.
Chapter 12: Setting Switc h Spanning Tree Prot ocols 142 Modifying Switch Spanning Tree Protocol Settings To modify port settings for Spanning Tree Protocol, do the following: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 143 Note Set the hello time, forward delay, and max-age fields according to the following formulas, as specified in I E EE Standard 802.1d: max-age <= 2 x (forward time - 1.
Chapter 12: Setting Switc h Spanning Tree Prot ocols 144.
145 Chapter 13 Setting Internet Gr oup Management Pr otocol (IGMP) Snooping This chapter provides a brief descripti on of IGMP Snooping and e x plains how to set this feature on the swit ch.
Chapter 13: Setting I nternet Group Management Protocol (IGMP) Snoop ing 146 Overview IGMP snooping allows the switch to control the flow of multicast packets from its ports. It enables the switch to fo rwa rd pa ckets of multicast gro ups to those ports that have host nodes.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 147 Displaying and Modifying IGMP Snooping Configuration To display and modify the IGMP Config uration se ttings, do the following: 1. Select the Switching tab. The Switching tab is displaye d.
Chapter 13: Setting I nternet Group Management Protocol (IGMP) Snoop ing 148 the switch floods the multicast packets o n all of the ports except those that receive the packets.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 149 Clearing the Routers List To clear the group membership on the IGMP Routers List, do the following: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58.
Chapter 13: Setting I nternet Group Management Protocol (IGMP) Snoop ing 150 Router IP — Indicates the IP addresses of the mu lticast routers. Time to Expiry — S pecifies the numbe r of seconds remaining before the switch times out a multicast router if there are no further IGMP queries from it.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 151 Disabling IGMP Snooping To disable the IGMP Configuration on the switch, do the following: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58.
Chapter 13: Setting I nternet Group Management Protocol (IGMP) Snoop ing 152 Displaying the Routers List To display the IGMP Routers List, do the following: 1. Select the Switching tab. The Switching tab is displayed. See Figure 19 on page 58. 2. From the Switching tab, select IGMP .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 153 Displaying the Hosts List To display the IGMP Hosts List, do the following: 1. Select the Switching tab. The Switching tab is displaye d. See Figure 19 on page 58. 2. From the Switching tab, select IGMP .
Chapter 13: Setting I nternet Group Management Protocol (IGMP) Snoop ing 154 IGMP Version — Indicates the IGMP ve rsions used by the host nodes. Time to Expiry — Specifies the number of seco nds remaining before host nodes are timed out if they do not se nd IGMP reports.
155 Chapter 14 Setting MAC Addr ess-based Port Security This chapter provides a brief descr iption of MAC address-based p ort security and explains how to set this feature on the switch .
Chapter 14: Setting M AC Address-based Port Sec urity 156 Overview This feature lets you control access to the ports on the switch based on the source MAC addresses of the network d evices. You specify the maximum number of source MAC addre sses that ports can learn.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 157 Guidelines Here are the guidelines to MAC address-based port security: The filtering of a p acket occurs on the ingress port, not on the egress port. Y ou cannot use MAC address-based port security and 802.
Chapter 14: Setting M AC Address-based Port Sec urity 158 Displaying the MAC Address-ba sed Port Security Settings To display the MAC address-based port security settings, do the following: 1. Select the Security tab. The Security tab is displayed. See Figure 52.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 159 Aging — Indicates the ports that can or cannot add the source MAC addresses as dynamic MAC address in the MAC address table. Ports that learn their maximum numbe rs of addresses can learn new addresses as inactive addre s ses are deleted from the table.
Chapter 14: Setting M AC Address-based Port Sec urity 160 Modifying the MAC Address-ba sed Port Security Settings To the modify the MAC address-based port securit y settings, do the following: 1. Select the Security tab. The Security tab is displayed.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 161 4. Change the following settings a s needed: Port Number — Indicates the port number . MAC Security — Activates or deactivates MAC address-based security on ports.
Chapter 14: Setting M AC Address-based Port Sec urity 162 Disabling MAC Address-base d Port Security Settings To deactivate MAC address-based port se curity settings, do th e following: 1. Select the Security tab. The Security tab is displayed. See Figure 52 on page 158.
163 Chapter 15 Setting RADIUS and T ACACS+ Clients This chapter provides a brief description of both the RADIUS and TACACS+ clients and explains how to configure these clients on the switch.
Chapter 15: Setting RADIUS and TACACS+ Clients 164 Overview The switch has RADIUS and TACACS+ clients for remote authentication. Here are the features that use remote a uthentication: 802.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 165 forwards the information to the servers when manag ers log on. The following steps illustrate the au thentication process that occurs between the switch and an authentication server wh en a manager logs on: 1.
Chapter 15: Setting RADIUS and TACACS+ Clients 166 Selecting the Authentication Method To choose either RADIUS or TACACS+ as the authentication method for the switch, do the following: 1. Select the Security tab. The Security tab is displayed. See Figure 52 on page 158.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 167 4. Click Apply . Choose the Apply button nearest the Authentication Method pull-down menu.
Chapter 15: Setting RADIUS and TACACS+ Clients 168 Configuring the Authentication Server To configure an authentica tion server, choose from the following procedures: “Configuring a T ACACS+ Ser.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 169 Note To define two or three servers that use different encryption keys, do not enter a global encryption key value on this web page. Instead, define the individual keys when yo u add the IP addresses of the servers to the client on the TACACS+ Add Page.
Chapter 15: Setting RADIUS and TACACS+ Clients 170 Key — Enter the secret key for this T ACACS+ server. The maximum length is 39 characters. Spa ces and special characters are not permitted. This value is needed when you configure a T ACACS+ client.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 171 4. Change the following fields as needed: Timeout Value — Indicates the length of the time, in seconds, that the switch waits for a response from a RADIUS server to an authentication request, before querying t he next server in the list.
Chapter 15: Setting RADIUS and TACACS+ Clients 172 6. Change the following settings as neede d: IP Address — Specifies the IP address of a RADIUS server on t he network.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 173 Deleting an Authentication Server To delete either an TACACS+ or RADIUS authen tication server, do the following: 1. Select the Security tab. The Security tab is displayed.
Chapter 15: Setting RADIUS and TACACS+ Clients 174.
175 Chapter 16 Setting 802.1x Port-based Network Access This chapter provides a brief description of the 802.1x Port-based Authentication feature and explains how to enable this feature on the switch, and configure authentication on a port. See the following sections: “Overview” on page 176 “Enabling 802.
Chapter 16: Setting 8 02.1x Port-based Network Access 176 Overview The 802.1x port-based network access control fe ature lets you control who can send traffic through a nd receiv e traffic from the individual switch ports.
AlliedWare Plus Version 2.1.2 Management Softwa re Web Browser User’s Guide 177 Enabling 802.1x Port-based Auth entication on the Switch To enable the 802.1x port-based Authenticat ion feature on a switch, do the following: 1. Select the Security tab.
Chapter 16: Setting 8 02.1x Port-based Network Access 178 Configuring 802.1x Port-based Authentication To configure 802.1x port auth entication on a port, do the following: 1. Select the Security tab. The Security tab is displayed. See Figure 52 on page 158.
AlliedWare Plus Version 2.1.2 Management Softwa re Web Browser User’s Guide 179 The Modify 802.1x Authentication page “Authenticator” exp ands. See Figure 61.
Chapter 16: Setting 8 02.1x Port-based Network Access 180 5. Modify the following fields as needed: Port Id — Indicates the port number. Port Role — Indicates that you’ve sele cted the port as an Authenticator. Authentication Mode — Indicate s the authentication mode.
AlliedWare Plus Version 2.1.2 Management Softwa re Web Browser User’s Guide 181 Supplicant-timeout — Sets the timer used by the switch to determine authentication server timeout condition s. The range is 1 to 600 seconds. The default valu e is 30 seconds.
Chapter 16: Setting 8 02.1x Port-based Network Access 182 Host Mode — Sets the ope rating modes on authenticator ports. Choose from the following: Single-host Specifies t he si ngle operating mode . An authenticator port set to this mode forwards only those packets from the one client who initially logs on.
AlliedWare Plus Version 2.1.2 Management Softwa re Web Browser User’s Guide 183 Displaying the 802.1x Authentication Port Settings To display the 802.1x Authentica tion port settings, do the following: 1. Select the Security tab. The Security tab is displayed.
Chapter 16: Setting 8 02.1x Port-based Network Access 184 Disabling 802.1x Port-based Au thentication on the Switch To disable the 802.1x port-based Authentica tion feature on a switch, do the following: 1. Select the Security tab. The Security tab is displayed.
AlliedWare Plus Version 2.1.2 Management Softwa re Web Browser User’s Guide 185 Disabling 802.1x Port-based Authentication on a Port To disable 802.1x port authen tication on a port, do the following: 1. Select the Security tab. The Security tab is displayed.
Chapter 16: Setting 8 02.1x Port-based Network Access 186.
187 Chapter 17 Setting IPv4 and IPv6 Management This chapter provides brief descripti ons of IPv4 and IPv6 Management and explains how to configure both types o f IP addresses on the switch.
Chapter 17: Setting I Pv4 and IPv6 Mana gement 188 Overview If you use the AlliedWare Plus web interfa ce to change the IP address of the switch, the web connection to the switch is lost.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 189 IP Management Guidelines See the following list for guidelin es about assigning the switch a management IPv4 or IPv6 address: Y ou can assign the switch one IPv4 address and one IPv6 address.
Chapter 17: Setting I Pv4 and IPv6 Mana gement 190 Assigning an IPv4 Address Use one of the following procedures to assign a static or DHCP IPv4 address to the switch.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 191 The IP Management Configuration p age with the S tatic IP Address field selected is displayed. See F i gure 65. Figure 65. IP Management Configuration Pag e with Static IP Address 3.
Chapter 17: Setting I Pv4 and IPv6 Mana gement 192 The Next Mask is a decimal number that represent s the number of bits, from lef t to right, that constitute the network portion of the address. For example: The decimal mask 16 is equivalent to th e mask 255.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 193 The IP Management Configuration p age with the DHCP IP Address selected is displayed. See Figure 66. Figure 66. IP Management Configuration Page with DHCP 4. To select a VLAN, use th e pull-down menu next to the Interface Name field.
Chapter 17: Setting I Pv4 and IPv6 Mana gement 194 Assigning an IPv6 Address To assign an IPv6 address to the switch, do the fo llowing: 1. Select the Management tab. The Management ta b is displayed. See Figure 64 on page 190. 2. From the Management tab, select IPv6 .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 195 Where n is a hexadecimal digit from 0 to F . The eight groups of digit s must be separa ted by colons. Group s where all four digits are “0” can be omitted. Leading “0’ s” in groups can also be omitted.
Chapter 17: Setting I Pv4 and IPv6 Mana gement 196 Displaying IP Addresses To display the IPv4 and IPv6 addresses as well as the IPv4 and IPv6 gateway addresses assigned to the switch, go to the Dashboard page. For an example, see Figure 4 on page 23.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 197 Deleting IP Addresses To delete an IP address from the switch, ch oose on of the following procedures: “Deletin.
Chapter 17: Setting I Pv4 and IPv6 Mana gement 198 Deleting an IPv6 Address To delete an IPv6 address, do the follo wing: 1. Select the Management tab. The Management ta b is displayed. See Figure 64. 2. From the Management tab, select IPv6 . The IPv6 Management Configuration p age is displayed.
199 Chapter 18 Setting LLDP and LLDP-MED This chapter provides a brief descrip tion of the Link Layer Discovery Protocol (LLDP) and Link Layer Disc ove ry Protocol for Media Endpoint Devices (LLDP-MED) features and expl ains how to enable these features on the switch.
Chapter 18: Setting L LDP and LLDP-MED 200 Overview Link Layer Discovery Protocol (LLDP) and Link Layer Discovery Protoco l for Media Endpoint Devices (LLDP-ME D) allow Ethernet network devices such a.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 201 Setting LLDP Locations Creating LLDP locations provides allo ws you to crea te IDs that are then used in following procedures. The proce dures in th is section allow you to create LLDP civic, Coordinate, an d ELIN locations.
Chapter 18: Setting L LDP and LLDP-MED 202 The Locations tab is displayed. See Figure 69. Figure 69. Locations Tab 4. From the Locations tab, select Civic .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 203 5. Click Add . The following fields are displayed: Id Country State County City Division .
Chapter 18: Setting L LDP and LLDP-MED 204 The LLDP Civic Location Page is displayed. See Figure 71 on p age 204. Figure 71. LLDP Civic Location Page— Modify.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 205 7. Change the fields as needed. Y ou must define the Id and Country fields. The remaining fields are optional. The fields are listed in step 5. Ea ch field can contain up to 255 characters.
Chapter 18: Setting L LDP and LLDP-MED 206 The LLDP Coordinate Location page is displayed. See Figure 73. Figure 73. LLDP Coordinate Location Page— Modify 6. Change the following fields as ne eded: Id — Specifies the LLDP Coordinate Location ID.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 207 point. For altitude in the number of floors, the range is -2097151 .0 to 2097151.0. Use the Altitude T ype field to specify meters or floors. Altitude Type — Choose between meters and floors.
Chapter 18: Setting L LDP and LLDP-MED 208 The LLDP ELIN Location List p age is displayed. See Figure 74. Figure 74. LLDP ELIN Location List Page 5. From the LLDP ELIN Location p age, click Add . The LLDP ELIN Location p age is displayed. See Figure 75.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 209 6. Change the following fields as needed: Id — Specifies an ID number for a LLDP-MED coordinate location entry on the switch. The range is 1 to 256. (This range is separate from the ranges for civic and coor din ate entries.
Chapter 18: Setting L LDP and LLDP-MED 210 Configuring LLDP and LLDP-MED To configure LLDP and LLDP-MED, perform t he following procedures: “Setting the Basic LLDP Configuration” on p age 210 .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 211 The LLDP Configuration page is displayed. See Figure 76. Figure 76. LLDP Configuration Page 4. Change the following fields as needed: Status — Indicates whether LLDP is enabled or disa bled on the switch.
Chapter 18: Setting L LDP and LLDP-MED 212 Non Strict Med TLV Order Chec k — Sets the switch to accept LLDP-MED advertisements even if the TLVs a re not in the standard order, as specified in ANSI/TIA-1057.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 213 The LLDP Port Config page is displaye d. See Figure 77. Figure 77. LLDP Port Config Page The following fields are displayed: Port Id — Indicates the port numb er.
Chapter 18: Setting L LDP and LLDP-MED 214 The Modify LLDP Port Configuration p age is displayed. See Figure 78. Figure 78. Modify LLDP Port Configuration Page 4. Change the setting s as needed. The definitions are listed in step 2. Click on a field to se lect it.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 215 2. From the Discovery & Monitoring tab, select LLDP . The LLDP tab app ears on the right. 3. From the LLDP tab , select Port Locations . The LLDP Port Location page is d i splayed.
Chapter 18: Setting L LDP and LLDP-MED 216 The Modify LLDP Port Location p age is displayed. See Figure 80. Figure 80. Modify LLDP Port Location Pa ge 5. Change the fields as needed . Click on the box next to a field to select it. The definitions are listed in step 3.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 217 The LLDP TL V tab is displayed in Figure 81. Figure 81. LLDP TLV Tab 4. Move your cursor to the right and select TLV a gain. The LLDP TLV page is displayed. See Figure 82.
Chapter 18: Setting L LDP and LLDP-MED 218 The Modify LLDP TL V page is displayed. See Figure 83. Figure 83. Modify LLDP TL V Page 6. Change the following fields as ne eded: Port Description — Indicates the port description of the neighbor ’s port.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 219 Management Address — Indicates the IP address of the local LLDP agent. This is used to obt ain information related to the local device. Port Vlan — Indicates the VID of the VLAN in which th e transmitting port is an unt agged member .
Chapter 18: Setting L LDP and LLDP-MED 220 Enabling LLDP- MED TLV To enable LLDP-MED TLV, do the following: 1. Select the Discovery & Monitoring tab. The Discovery & Monitoring tab is displayed. See Figure 68 on pa ge 201. 2. From the Discovery & Monitoring tab, sele ct LLDP and then select TLV .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 221 Location — Location information configured for the port, in one or more of the following formats: - Civic locat.
Chapter 18: Setting L LDP and LLDP-MED 222 5. Change the following fields as ne eded. Capabilities — Specifies the capa bilities TLV. Network-policy — Specifies the network policy TLV. Location — Specifies the location identification TLV.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 223 Displaying LLDP Neighbor Information To display LLDP Statistical information, do the followin g: 1. Select the Discovery & Monitorin g tab. The Dis covery & Monitoring t ab is displa yed.
Chapter 18: Setting L LDP and LLDP-MED 224 System Capabilities — Ca pabilities that are supported and enabled on the neighbor . The System Capabilities codes are: O = Other P = Repeater B= Bridg.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 225 Displaying LLDP Statistics To display LLDP Neighbor informa tion, do the following: 1. Select the Discovery & Monitorin g tab. The Dis covery & Monitoring t ab is displa yed.
Chapter 18: Setting L LDP and LLDP-MED 226 New Entries — Indicates the numbe r of times the information advertised by neighbors has been inserted into the neighbor t able. Deleted Entries — Indicates the numbe r of times the information advertised by neighbors has been removed from the neighbor tabl e.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 227 The fields are described in step 3. These f ields list the st atistics for all of the ports . 4. Click OK to return to the LLDP Statistics Page with the Port Statistics Tab selected.
Chapter 18: Setting L LDP and LLDP-MED 228 Displaying LLDP Locations To display the LLDP Civic, Coordinate, an d ELIN locations, use the following procedures: “Displaying Civic Locations” on p.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 229 House Number House Number Suffix Landmark Additional Information Name Postal Code Buildin.
Chapter 18: Setting L LDP and LLDP-MED 230 The following fields are displayed: Id — Specifies the LLDP Coordinate Location ID. Latitude — Indicates the latitude value in decimal d egrees. The range is -90.0º to 90.0º. The field accept s up to two digits to the right of the decimal point.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 231 The following fields are displayed: Id — Specifies an ID number for a LLDP-MED coordinate location entry on the switch. The range is 1 to 256. (This range is same as the ranges for civic and coordinate en tries.
Chapter 18: Setting L LDP and LLDP-MED 232 Displaying LLDP and LLDP-MED Settings To display the LLDP Civic, Coordinate, an d ELIN locations, use the following procedures: “Displaying the Basic L.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 233 standard order, as specified in AN SI/TIA-1057. This configuration is useful if the switch is connect ed to devices that send LLDP-MED advertisements in which the TLVs are not in the standard order.
Chapter 18: Setting L LDP and LLDP-MED 234 Med Notification — Indicates the switch sends LL DP-MED topology change notifications when device s are connected to or disconnected from the specified ports. By default , this field is not selected. Displaying Port Locations To display the LLDP port locations, do the fo llowing: 1.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 235 4. From the LLDP TLV tab, select TLV again. The LLDP TL V page is displayed. See Fig ure 82 on page 217. The following fields are displayed: Port Id — Indicates the port numb er.
Chapter 18: Setting L LDP and LLDP-MED 236 Power Management — Indicates the power via MDI ca pabilities of the port. Link Aggregation — Indicates whether the port is ca pable of link aggregation and, if so, whether it is cu rrently a member of an aggregator .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 237 Inventory-management — The current hardware plat form and the software version, identical on every port on the .
Chapter 18: Setting L LDP and LLDP-MED 238 Disabling LLDP on the Switch To disable the LLDP feature on a switch, do the followin g: 1. Select the Discovery & Monitoring tab. The Discovery & Monitoring tab is displayed. See Figure 68 on pa ge 201.
239 Chapter 19 Setting sFlow This chapter provides a brief description of the sFlow feature and explains how to enable this feature on the switch and o n a port.
Chapter 19: Setting s Flow 240 Overview The sFlow agent allows the switch to gather data about the traffic on the ports and to send the data to sFlo w collectors on your network for analysis. You can use the information to monitor the performance of your network or identify traffic bottlenecks.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 241 To configure the ag ent to forward these port statistics t o the collectors, you have to specify polling rates, which define the maximum amount of time permitted between su ccessive queries of the counters of a port by the agent.
Chapter 19: Setting s Flow 242 Enabling sFlow on the Switch To enable the sFlow feature on a switch, do the following: 1. Select the Discovery & Monitoring tab. The Discovery & Monitoring tab is displayed. See Figure 89 on pa ge 242. 2. From the Discovery & Monitoring tab, sele ct sFlow .
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 243 Configuring sFlow on a Port To configure the sFlow feature on a port, do the following: 1. Select the Discovery & Monitorin g tab. The Dis covery & Monitoring t ab is displa yed.
Chapter 19: Setting s Flow 244 4. Change the following fields as ne eded: Port Number — Indicates the port number. Polling Interval — Sets the polling intervals for the ports. T his controls the maximum amount of time permitted between successive pollings of the packe t counters on the por ts by the sFlow agent.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 245 Specifying an sFlow Collector Use this procedure to specify the IP addre sses and the UDP ports of the sFlow collectors on your network. The packet sampling da ta and the packet counters are sent by the switch to the collectors specified.
Chapter 19: Setting s Flow 246 The Sflow Collector p age is displayed. See Figure 92. Figure 92. Sflow Collector Page 5. Change the following fields as ne eded: IP Address — Specifies the IPv4 address of the sFlow collector on your network. Enter the IPv4 address in the following format: xxx.
AlliedWare Plus Version 2.1.2 Management Soft ware Web Bro wser User’s Guide 247 Displaying the sFlow Settings To display the sFlow settings, do the following: 1. Select the Discovery & Monitorin g tab. The Dis covery & Monitoring t ab is displa yed.
Chapter 19: Setting s Flow 248 End of Document.
An important point after buying a device Allied Telesis AT-9000/28 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Allied Telesis AT-9000/28 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Allied Telesis AT-9000/28 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Allied Telesis AT-9000/28 you will learn all the available features of the product, as well as information on its operation. The information that you get Allied Telesis AT-9000/28 will certainly help you make a decision on the purchase.
If you already are a holder of Allied Telesis AT-9000/28, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Allied Telesis AT-9000/28.
However, one of the most important roles played by the user manual is to help in solving problems with Allied Telesis AT-9000/28. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Allied Telesis AT-9000/28 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center