Instruction/ maintenance manual of the product Sienna Indoor Gas Fireplace Enviro
Go to page of 32
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 50-1096 S i e n n a This appliance is only for use with the type of gas indicated on the rating plate.
FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst.
T able of Contents 3 Safety Precautions.....................................................................................................2 T able of Contents...........................................................................................
DIRECT VENT: This type is identied by the sufx DV . This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved f or installations from 0 feet to 4500 f eet (1372 m) above sea level.
Specific a tions R ATING L ABEL L OCATION : The rating label is located under the control panel and is attached to a rectangular metal sheet that is chained to the replace.
6 Specific a tions 15 1 / 16 " (383 mm) 30 1 / 2 " (775 mm) With Trim 33 3 / 16 " (343 mm) Without Trim 33" (338 mm) 20 5 / 8 " (523 mm) 22 3 / 4 " (577 mm) 22 11 / 16 &q.
7 WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE. P ILOT L IGHTING I NSTRUCTIONS : Figure 3. Lighting instruction label. 1. STOP! Read the safety information above on this label.
8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating T URN O FF U NIT : Flip switch to OFF to turn off burners only . If the replace is to be turned off for the season, or for servicing, turn the gas shut off valv e to OFF .
9 Maintenance And Ser vice Warning: F ailure to position the parts in accordance wi th this manual, or failure to use only parts specically approved with this appliance, ma y result in property damage or personal injury . At least once a year , run through the following procedures to ensure the system is clean and working properly .
Maintenance And Ser vice QUALIFIED INST ALLERS ONL Y G LASS D OOR R EMOVAL : Blower / F an Gas & Electrical T ray Compl ete Burner T op with Grate Attached Log Support T ray Figure 10: Removing burner and gas tray. 1. T urn the unit off and allow the unit to cool completely .
Maintenance And Ser vice F UEL C ONVERSION : TO BE INST ALLED BY A QU ALIFIED SERVICE A GENCY ONL Y Please read and understand these instructions before installing. Figure 11: Removing valve cap. a) Remove the main burner orice with a inch deep sock et.
12 Maintenance And Ser vice c) Check that the screw is clean and if necessary remove dirt. d) Flip the screw (refer to Figure 13). e) Using the Allen wrench as shown in Figure 12, rotate the screw clockwise until a torque of 9 inch lbs. WARNING! Do not over tighten the screw.
Initial Inst alla tion WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. C LEARANCES TO C OMBUSTIBLES : Maintain sufcient clearances f or operation, service and maintenance.
14 Initial Inst alla tion Check draft with a match or smoke in a " (6 mm) tube located here. M INIMUM F IREPLACE S IZE : Description of Fireplace Dimension Direct V ent B-V ent Width At Back 2.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y D IRECT V ENT M ODEL : WARNING: This appliance has been designed to draw room air for proper heat circulation from the sides of the unit. Blocking or modifying the louvers in any way can create hazardous situations.
16 In st al l se al ed t hr oa t co nn ec to r or flashing to prevent leakage of room air up through chimney . DV O nl y: B ef or e in st al li ng v e nt liners, mark each liner on both ends to designate which is the intake and the exhaust. Me asu re th e he igh t of t he ch imn ey b e f or e h a n d a n d p ur c h a s e t h e appropriate kit.
17 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS : F an Control Black White White Black Green/Y ellow Green Black Power Cord 120V AC F AN 120 o F (49 o C) T emperature Sensor CNT2 CNT3 CNT1 CNT4 The fan is thermostatically controlled and it will not oper ate if the appliance is cold.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y G AS L INE C ONNECTION : Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
19 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y C ONVERTING A D IRECT V ENT F IREPLACE T O A B-V ENT F IREPLACE : Direct V ent Connector Assembly Fresh Air Inlet Covers 1. Remove the Direct V ent chimney connector assembly by taking out the two (2) T -20 screws at the front of the unit.
Second ar y Inst alla tion Figure 29: Filler panel with trim installation. I NSTALLATION OF S URROUND P ANEL : The Sienna must have one of the panels installed around the unit; the unit panel, the ller panel, or the ller panel with trim.
21 Second ar y Inst alla tion L OG S ET AND E MBER I NSTALLATION : NOTE: The logs are fragile and should be handled gently. The placement of the logs is not arbitrary . If they are positioned incorrectly , the ames can be “pinched” and will not burn correctly .
Second ar y Inst alla tion Figure 33. Third Stage Log Set Installation. Figure 35. Fifth Stage Log Set Installation. Figure 34. Fourth Stage Log Set Installation. Figure 34: Once the logs are in position the provided rock wool can be placed irregularly in front of the burner .
23 Second ar y Inst alla tion Figure 36. Sienna complete log set-up with embers burning. NO TE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot.
Second ar y Inst alla tion R EMOVING T HE B RICK P ANEL : The brick panel set is fragile, handle with extreme care. The brick panel set comes pre-installed. The centre and top panel are the only panels that need to be removed if the complete gas and electrical tray assembly must be removed.
25 T rouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temperatur e.
P ar ts List- Unit Components Reference Number Part Description Part Number 1 120°F Ceramic Fan T emperature Sensor EC-001 2 300°F (149°C) Manual Reset Spill Switch (Normally Closed) EC-003 3 S.
27 P ar ts Diagr am - Components SIENNA - Components October 2004 .
P ar ts Diagr am - Burner SIENNA - Burner October 2004 28.
29 P ar ts List - Options Reference Number Option Description Part Number 1A The Cottage T rim Kit - Gold 50-548 1A The Cottage T rim Kit - Pewter 50-549 1A The Cottage T rim Kit - Antique Copper 50-5.
P ar ts Diagr am - Options SIENNA - Options October 2004 30.
31 W arr anty Sherwood Industries Ltd. offers a Limited Lifetime Warr anty on this gas product. This Limited Lifetime W arr anty cov ers the appliance for a period of seven years from the date of installation. This warr anty applies only to the original owner in the original location.
Inst alla tion Da t a Sheet The following information must be recorded by the installer for w arrant y purposes and future r eference. NAME OF OWNER: _________________________________________ ADDRESS:.
An important point after buying a device Enviro Sienna Indoor Gas Fireplace (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro Sienna Indoor Gas Fireplace yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro Sienna Indoor Gas Fireplace - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro Sienna Indoor Gas Fireplace you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro Sienna Indoor Gas Fireplace will certainly help you make a decision on the purchase.
If you already are a holder of Enviro Sienna Indoor Gas Fireplace, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro Sienna Indoor Gas Fireplace.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro Sienna Indoor Gas Fireplace. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro Sienna Indoor Gas Fireplace along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center