50-765 PELLET ST OVE MERIDIAN SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE O WNER ’S MANU AL Freestanding and Fireplace Insert PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER.
T able of Contents Introduction......................................................................................................................................3 Pellet Quality .....................................................................
Introduction P ELLET Q UALITY : Pellet quality is important, please read the following: Your enviro pellet stove has been designed to burn wood pellets only.
Introduction I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
Introduction ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, wel l away from all combustible materials pending final disposal.
Oper a ting Instructions A UTOMATIC S AFETY F EATURES : Y our pellet Stove has the following safet y features: A) The stov e will shut off when the fire goes out and the exhaust temper ature drops below 120 °F (49°C). B) The stove has a high temperature safety switch.
Oper a ting Instructions O PERATING Y OUR P ELLET S TOVE : PRE-BURN INSTRUCTIONS : The burn pot liner holes must be clear and the liner installed correctly against the ignitor tube for proper oper ation. Check the hopper for enough pellets to start the unit.
2-3 Days / Weekly Semi-annually or 2 T ons of Fuel Burn Pot and Liner Exhaust V ent Ash Pan Fresh air Intake T ube Inside Firebox Blower Mechanisms Door Glass Heat exchanger tubes Heat exchanger tubes.
ASH PAN AND DOOR GASKETS (weekly) After extended use the gasketing ma y come loose. T o repair this, glue the gasketing on using high- temperature fiberglass gasket glue av ailable from your local ENVIRO dealer . This is important to maintain an airtight assembly .
EXHAUST PASSAGES (season) Removal of the firebox backing for bi- annual cleaning (refer to Figure 5): • Open the door by lifting the handle, remove the burn pot and burn pot liner . • Lubricate all screws with penetrating oil. • Remo ve the four (4) screws that hold the brick liner retainers in place.
Inst alla tion D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles (see I NSTALLATION - C LEARANCES TO C OMBUSTIBLES - F REESTANDING , I NSTALLATION - A LCOVE C LEAR ANCES - F REESTANDING , and I NSTALLATION - C LEARANCES TO C OMBUSTIBLES - F IREPLACE I NSERT .
32 1 / 2 " (826mm) 24 7 / 8 " (632mm) 24 3 / 4 " (629mm) Inst alla tion D IMENSIONS - F REESTANDING : Figure 8: Meridian Freestanding Dimensions. 23 3 / 4 " (604mm) 12 7 / 8 " (326mm) 22 7 / 8 " (583mm) 23 7 / 8 " (605mm) Figure 9: Meridian Fireplace Insert Dimensions.
Minimum 6" (150mm) This pellet stove requires floor protection. The floor protection must be non-combustible, extending beneath the stove the full width and depth of the unit including 6“ (150 mm) in front for ember protection. A LCOVE C LEARANCES - F REESTANDING : Figure 10: Meridian on Floor Protection.
Inst alla tion C LEARANCES TO C OMBUSTIBLES - F IREPLACE I NSERT : The fireplace insert must be installed into a masonry fir eplace. This model includes a surr ound faceplate and a pedestal. When installing this unit, ensure that the pedestal is remov ed from the inside of the hopper and installed on the bottom of the unit.
Ground wire directly connected to metal chassis. Hearth Pad Flooring Steel Frame 1 / 4 " Lag bolts securely fastened Figure 17: Mobile Home Install Mounting. M OBILE H OME I NSTALLATION - F REESTANDING : ● Secure the heater to the floor using the holes in the pedestal of the appliance.
EXHAUST Freestanding Insert Base of unit to center of flue 18 ” (473 mm) 9 1 / 16 ” (229 mm) Side of unit to center of flue 6 11 / 16 ” (170 mm) 6 ” (156 mm) Center of unit to center of flue 5 ” (146 mm) 5 ” (146 mm) FRESH AIR INTAKE.
fumes such as stairwells, cover ed breezeway , etc. 2. V ent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be requir ed.
Figure 22: Corner Installation. 3" (7.5 cm) 3" (7.5 cm) Fresh Air Intake W all thimble manufactured by pellet vent manufacturer . Inst alla tion C ORNER T HROUGH W ALL I NSTALLATION - F REES.
Exhaust T ube 3" (75mm) or 4" (100mm) "PL" or "L" vent W all Thimble 45° Elbow with screen or T ermination Cap Fresh Air Intake High T emperature RTV Silicone Required W.
Wall framing Wall thimble Termination cap Vertical section of vent pipe Horizontal frame for thimble Clean out tee 90°elbow Concrete Wall Wall framing Wall.
Rain cap - ensure cap is at least 2 feet (610mm) above the roof at the lowest point Storm collar Roof flashing Roof rafter Fire stop with Support Collar Ceiling joist V ertical vent pipe Clean out tee with Pipe adapter ENVIRO Meridian NOTE: All vent sections must maintian 3" (76 mm) clearances to combustibles.
Inst alla tion O UTSIDE V ERTICAL I NSTALLATIONS - F REESTANDING : T o accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “ I NSIDE V ERTICAL I NSTALLATIONS - F REESTANDING ” section and then finish it by performing the f ollowing (refer to Figure 28).
Rain cap Storm collar Seal plate (cover plate) Existing masonry flue V ent pipe (single wall stainless flex pipe or solid PL vent) Fireplace damper location Clean out tee Existing fireplace Flexible vent connector (use this 5' [1520 mm] section of pipe to vent past fireplace damper or small shelf) 1.
Inst alla tion I NSTALLATION WITH E XTERIOR M OUNTED E XHAUST B LOWER - F REESTANDING : The MERIDIAN can be equipped with an externally mounted exhaust blower (PAR T #20-070). This optional kit will include all components necessary to install the exhaust blower on any external vertical wall surface.
TO SUPPLY POWER TO THE EXHAUST BLOWER: Install an amour coated electrical cable from the exhaust blower housing, thr ough the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar . Hook up to wires from the wiring harness for the exhaust blower .
Inst alla tion T HROUGH W ALL V ERTICAL I NSTALLATION W ITH E XHAUST B LOWER - F REESTANDING : Ref er to I NSTALLATION - I NSTALLATION WITH E XTERIOR M OUNTED E XHAUST B LOWER - F REESTANDING and I NSTALLATION - O UTSIDE V ERTICAL I NSTALLATIONS - F REESTANDING .
A noncombustible hearth pad must cover combustible flooring underneath, as well as 6” (150 mm) in front of the heater and 6” (150 mm) to the side of the heater 1. Install the hearth pad. 2. Lock the fireplace damper in the open position. 3. Install a positive flue connector at the fireplace damper .
Inst alla tion A SSEMBLY AND I NSTALLATION OF I NSERT S URROUND P ANELS - F IREPLACE I NSERT : I NSTALLATION AND R EMOVAL OF C ONTROL P ANEL IN T HE S URROUND P ANEL - F IREPLACE I NSERT : When installing the circuit boar d contr ol panel into the surround panel, the surr ound does not need to be assembled.
Figure 42: Installed Surround Panel. 6. Place the second side of the trim on the surround panel in the same manner used on the first side and secure in the same manner . 7 . On the side trims, ther e are holes 2” (50 mm) f rom either end. Use a Phillips screwdriver to place a #8 screw 1” long in each hole and tighten (refer to Figure 41).
Inst alla tion P LATED T RIM I NSTALLATION : TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE TRIMS WHEN PELLET STOVE IS HOT! REMOVAL OF SIDE TRIMS: When stove is off and cool, open the door.
TOOLS REQUIRED: ● 11 / 32 ” socket or wrench REMOV AL OF DOOR COVER: When stove is off and cool, open the door . Remove the four (4) #8 hex nuts around the inside of the glass retainer shown in Figure 46. Remo ve door cover from door by gently sliding the studs out of the holes.
2. Open the right cab side to expose thermostat wires and disconnect. Install 18 gauge (see W IRING D IAGRAM ) or heavier wire through the grommet in the back, from the stove to the thermostat.
The slider damper is located behind the left cab side. The door must be open for the cab side to be removed on all models. On freestanding model loosen the two T -20 torx screws, one abov e and one below hinge, swing open left panel to access.
T roubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oil lubrication.
T roubleshooting hose from vacuum switch. Check exhaust vacuum readings by placing the open end of the vacuum hose on a Magnahelic Gauge (readings must be above 0.18” to 0.20” W .C. (44.8 to 49.8 P a) on low fire). If the motor fails to reach a 0.
T roubleshooting 6. The 200 °F ( 93 °C) high limit temperature sensor has tripped. ü Reset sensor and determine cause – was it convection blower failure or 160 °F ( 71 °C) temperature sensor failure? Bypass the 160 °F ( 71 °C) sensor , does the convection blower come on high? If no, replace the blower .
Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey Grey Grey Purple Purp.
Reference Number Description Part Number 1 120 °F (49 °C) Ceramic F an T emperature Sensor EC-001 Domestic Power Cord - 115V EC-042 2 Auger Motor - 115V EF-001 3 Convection Blower 115V EF-002 4 Fan .
Reference Number Description Part Number 23 Louver Bar Set - Gold 50-655 23 Louver Bar Set - Pewter 50-656 23 Louver Bar Set - Antique Copper 50-657 24 Burn Pot 50-658 25 Ash Pan (Freestanding) 50-659.
MERIDIAN - Freestanding Steel Parts December 2004 .
MERIDIAN - Insert Steel Parts December 2004 P ar ts Diagr am - Inser t Steel 41.
MERIDIAN - Components December 2004 P ar ts Diagr am - Components 42.
W arr anty Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-y ear warr anty is provided on all electrical components.
NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:__.
An important point after buying a device Enviro Meridian (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro Meridian yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro Meridian - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro Meridian you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro Meridian will certainly help you make a decision on the purchase.
If you already are a holder of Enviro Meridian, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro Meridian.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro Meridian. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro Meridian along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center