Instruction/ maintenance manual of the product EF2 Enviro
Go to page of 40
EF-119 PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER.
T able of Contents 2 Introduction...................................................................................................................................3 P ellet Quality .....................................................................
Introduction P ELLET Q UALITY : Pellet quality is important, please read the following: Your enviro pellet stove has been designed to burn wood pellets only.
Introduction I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
Introduction ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, wel l away from all combustible materials pending final disposal.
Oper a ting Instructions A UTOMATIC S AFETY F EATURES : Y our pellet Stove has the following saf ety featur es: A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C). B. The stove has a high temperature safety switch.
Oper a ting Instructions O PERATING Y OUR P ELLET S TOVE : C o n v e ct i on B lo w er S p e e d C on t ro l K n o b A G r e e n L ig h t ( A u g e r Li g ht ) D i a l - A- F ir e H e a t O u tp u t K n o b B A u t o / M an u al R o c k e r Sw i tc h Figure 3: Dial-A-Fire control panel.
R outine Cleaning and Maintenance NOTE: Do not use abrasiv e cleaners to clean the surface or any part of the sto ve. The following should be inspected periodically to ensure that the appliance is ope.
ASH PAN (2-3 days) Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality . Dump the ashes into a metal container stored away from combustibles.
Installation of firebox backing: • Install the side panels in place. Insert center panel, hold the panels in place • Install the top rod by sliding it into one side panel then across into the other panel. Screw rod in place. • Re-install steel brick liner and screw in place.
Inst alla tion D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a v entilated cra wlspace. 3.
Inst alla tion D IMENSIONS - F REESTANDING : .
Inst alla tion C LEARANCES TO C OMBUSTIBLES - F REESTANDING : When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non- combustible hearth pad must be under the unit.
Inst alla tion C LEARANCES TO C OMBUSTIBLES - B UILT -I N H EATER : Ref er to Figures 11 and 12. Side wall to unit - 8 inches (20.3 cm) Mantel projection - 10 inches (25.4 cm) Mantel to top of unit - 8 inches (20.3 cm) T op facing to unit - 8 inches (20.
15 hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust abo ve the inlet elev ation.
Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 1” minimum (42 mm) ID (inside diameter) steel, aluminum or copper pipe should be used.
Figure 21: Corner Installation. Inst alla tion M OBILE H OME I NSTALLATION - F REESTANDING : 2" (5 cm) 2" (5 cm) 6" (15 cm) Floor Protection Fresh Air Intake W all thimble manufactured by pellet vent manufacturer .
Inst alla tion H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION - F REESTANDING : Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor , or ceiling.
Inst alla tion 10. The pipe must extend at least 12” (30 cm) awa y from the building. If necessary , bring another length of pipe (PL type) to the outside of the home to connect to the first section. Do not forget to place high temperatur e silicone around the pipe that passes through the thimble.
Inst alla tion I NSIDE V ERTICAL I NSTALLATIONS - F REESTANDING : 1. Choose a sto ve location that is ideal. See the section “ D ECIDING W HERE TO L OCATE Y OUR P ELLET A PPLIANCE . ” Non-combustible floor protection. Existing floor (combustible) 6" (15 cm) 3" (7.
Inst alla tion Non-combustible floor protection. Existing floor (combustible) 6" (15 cm) Rain cap Flashing 24" (61 cm) 2" (5 cm) T ee with cleanout Fresh air intake 3" (7.5 cm) Clearance Support bracket T ype "L" vent Figure 27: Outside V ertical Installation.
Inst alla tion .
.
Non-combustible floor protection. Existing floor (combustible) 6" (15 cm) 3" (7.5 cm) Pedestal W all thimble Fresh air intake Rodent mesh cap 45° elbow 12" (30.
Inst alla tion I NSTALLATION AND R EMOVAL OF T HE S URROUND P ANELS - FPI AND BIH: T wo (2) pieces make up one (1) corner bracket Corner Brackets Figure 36: Assembling the Surround Panel, back view . Figure 34: Assembling T rim for Surround Panel. Figure 35: Panel placed on unit.
REMOVAL: When maintenance is required on the unit the surround must be removed. F ollow steps 3 through 6 in reverse order . The side panel can r emain attached because they swing forward for easy access (refer to Figure 37).
T roubleshooting DO NOT: w Switch the stove On and OFF r apidly . This may cause current spikes, which could shorten the life of the electrical components. w Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly .
T roubleshooting 3. The stove will not function in the “AUTO” mode when hot. w If the unit f ails to oper ate, by-pass the auto side of the switch b y inserting a jumper wire between the dual black wires and the dual brown wires located on the back of the switch.
29 T roubleshooting 6. Everything else in the stove operates but the ignitor will not light the pellets. w Check the burn pot liner placement, the burn pot liner should be tight against the ignitor . w Check all the electrical connections on the 120°F (49°C) temperature sensor located on the exhaust channel.
8. The dial-a-fire has no effect on the fire. w Make sur e all connections to the timer control module are secure. w P erform a resistance test to the dial-a-fire potentiometer by placing the two (2) test leads from a multimeter into the leads of the potentiometer .
31 W iring Diagr am 120 o F (49 o C) Ignitor Temperature Switch 200 o F (93 o C) High Limit Temperature Sensor 160 o F (71 o C) Convection Temperature Switch Purple Purple Black 120 o F (49 o C) Exhau.
P ar ts List 32 Reference Number Description Part Number 1 120°F (49°C) Ceramic Fan T emp Sensor EC-001 Freestanding Fan Controller Knob EC-040 Domestic Power Cord - 1 15V EC-042 2 Auger Motor - 1 1.
33 P ar ts List Reference Number Description Part Number ” Round Door Gasket 72” (1.8 m) EF-057 Window Channel T ape 60” (1.5 m) EF-058 17 FPI & BIH Ash Pan Latch EF-060 Glass Set With T .
P ar ts List 34 Reference Number Description Part Number Fireplace Insert Cabinet Side Right EF-132A 32 Freestanding Pedestal Complete EF-138 Ignitor T ube Only EF-140 33 Freestanding Hopper Lid Hinge.
35 P ar ts List - Options Reference Number Description Part Number Log Set 20-036 47 Decorative T rivet - Painted EF-148 47 Decorative T rivet - Gold EF-149 Louvre T rim - Brass 50-339 Louvre T rim - .
P ar ts Diagr am - Components .
37 P ar ts Diagr am - Steel .
W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do.
39 W arr anty 8. The Limited W arranty will co ver glass thermal breakage only and will not cover misuse of the stov e glass, including but not limited to glass that is struck, has surface contaminates or has had harsh or abr asive cleaners used on it.
40 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE.
An important point after buying a device Enviro EF2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro EF2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro EF2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro EF2 you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro EF2 will certainly help you make a decision on the purchase.
If you already are a holder of Enviro EF2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro EF2.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro EF2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro EF2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center