Instruction/ maintenance manual of the product C-11288 Enviro
Go to page of 34
BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL EG31-118 F O C U S SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE This appliance is only for use with the type of gas indicated on the rating plate.
FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst.
T able of Contents 3 Safety Precautions.....................................................................................................2 T able of Contents...........................................................................................
DIRECT VENT: This type is identied by the sufx DV . This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. This appliance has been tested and approved f or installations from 0 f eet to 4500 feet (1372 m) abov e sea level.
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. Specific a tions 5 12 1 / 16 " (30.6cm) 18" (45.7cm) 30 5 / 16 " (77cm) 14 3 / 16 " (36.
Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating L IGHTING I NSTRUCTIONS : Thermopile Thermocouple Figure 3: Gas Valve. Figure 4: Pilot Burning. 6 1. STOP! Read the safety information above on this label.
Move the rod located behind the piezo ignitor to increase or decrease primary air at the venturi tube. There is only one (1) venturi and one (1) air shutter to be adjusted. When installing the burner top , ensure that the venturi tube is engaged to the air shutter adjustment rod.
8 Maintenance And Ser vice R OUTINE M AINTENANCE : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything.
9 to prevent personal injury . When the glass door assembly is being transported, i t must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or brok en. Remo val and replacement of the glass from the door must be done by a licensed or qualied service person.
Maintenance And Ser vice F UEL C ONVERSION : Figure 8: Removing valve cap. 5. Convert the burner orice(s): a) Remove the main burner orice with a inch deep sock et. b) Put a bead of pipe-thread sealant or approved T eon tape on the orice threads before installing into the br ass elbow .
11 Maintenance And Ser vice b) Insert a 5 / 32 ” or 4 mm Allen wrench into the hexagonal key- way of the screw (see Figure 9), rotate it counter -clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt.
12 Initial Inst alla tion Check draft with a match or smoke in a " (6 mm) tube located here. Warning: F ailure to position the parts in accordance with this manual, or failure to use only parts specically approved with this appliance ma y result in property damage or personal injury .
P REPARING Y OUR F OCUS F OR I NSTALLATION : 1. Remove the appliance and surround panels from the packaging; check to make sure there is no damage. Carefully check the glass door . Do not use the unit if it is damaged. In the event damage is found, please report it to both the courier and y our dealer as soon as possible.
a) Attach one side trim to the top trim using a corner bracket (see Figure 16) to secure pieces together . There are two (2) main pieces to each corner brack et (see Figure 17). When installing the corner pieces into the trim the “B F ACE” sides must face each other and the screw heads are to face out.
Figure 19: Surround Panel installation. 15 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y The standard surround panel comes with a f an controller and burner switch so the set that comes with the unit panel can be kept as spare parts.
16 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y C ONVERTING A D IRECT V ENT F IREPLACE T O A B-V ENTED F IREPLACE : existing and attach with three (3) sheet metal screws ev enly spaced to new 4’’ chimney connector . 5. T est re the appliance and ensure proper operation.
Insta ll sealed t hroat con nector or flashing to prevent leakage of room air up through chimney . DV Only: Before installing vent liners, mark each liner on both ends to designate which is the intake and the exhaust. Measure the height of the chimney be fo re h an d and p ur ch as e th e appropriate kit.
18 The Focus will operate without electrical power . This model has a Millivolt gas control which uses the pilot ame to generate enough electricity to operate the main burners.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y G AS L INE C ONNECTION : Warning: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
Second ar y Inst alla tion L OG S ET AND E MBER I NSTALLATION : The placement of the logs is not arbitr ary . If they are positioned incorrectly , the ames can be “pinched” and will not burn correctly . The burner comes with placement pins and rest areas, which mak e alignment easier .
21 Second ar y Inst alla tion B RICK P ANEL I NSTALLATION : Caution: Use only the type of ember material supplied with this replace. Due to the irregular size of the ember material, there may be more than required. Use of other foreign materials on the burners may create dangerous conditions.
T rouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temper ature.
23 P ar ts List - Components Reference Number Part Description Part Number 1 120°F (49°C) Ceramic Fan T emperature Sensor EC-001 2 300°F (149°C) Spill Switch EC-003 3 Thermocouple EC-009 3 Spark E.
Reference Number Part Description Part Number 10 Door Only - Painted EG31-092 1 1 V enturi EG31-099 Owner ’s Manual EG31-1 18 ” NTP Male Comp.
25 P ar ts Diagr am - Bod y .
P ar ts List - Surrounds & F ascia Reference Number Part Description Part Number Steel Bay F ace - Nickel 50-092 Steel Bay F ace With Glass - Painted 50-141 Steel Bay Cover - Gold 50-142 Steel Bay.
27 P ar ts Diagr am - Surrounds & F ascia .
Reference Number Part Description Part Number Cast surround only - Painted 30-036 Cast surround only - Antique White 30-035A W Cast surround only - Diamond Black 30-035DB Cast surround only - Inferno .
29 Reference Number Part Description Part Number 31 Cast front only (no surround, glass, valve door , or clip) - Antique White 50-403 31 Cast front only (no surround, glass, valve door , or clip) - Di.
P ar ts Diagr am- Cast Ba y F ront 30.
31 W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do.
W arr anty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this W arranty policy . P erformance problems due to operator error will not be covered by the Limited W arr anty policy .
33 20. Sherwood Industries Ltd. is free of liability for any damages caused by the replace or stove, as well as inconvenience expenses and materials.
34 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDR.
An important point after buying a device Enviro C-11288 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro C-11288 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro C-11288 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro C-11288 you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro C-11288 will certainly help you make a decision on the purchase.
If you already are a holder of Enviro C-11288, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro C-11288.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro C-11288. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro C-11288 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center