Instruction/ maintenance manual of the product C-10791 Enviro
Go to page of 35
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. DIRECT VENT FIREPLACE BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE I.
2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst.
T able of Contents 3 Safety Precautions.....................................................................................................2 T able of Contents...........................................................................................
4 DIRECT VENT ONLY: This type is identied by the prex DV . This appliance draws all of its air f or combustion from outside the dwelling, through a specially designed v ent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) abov e sea level.
.
Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.
2. Start the pilot by pr essing the gas contr ol knob and turning it to PIL O T . While holding the gas control knob in, press the piezo ignitor sever al times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 3).
8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating E) T urn on all electrical power to the unit. NOTE: Check that all burner holes are lit. TO TURN GAS FIREPLACE OFF: Flip switch to OFF to turn off burners only .
Maintenance And Ser vice R OUTINE M AINTENANCE : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything.
10 Maintenance And Ser vice C LEANING D ECORATIVE S URFACES : P ainted and porcelain faces should be wiped with a damp cloth periodically . If a plated face has been purchased, it should be unpacked/unwrapped carefully to avoid getting anything on the surface of the nish, including cleaners, polish and nger prints.
11 F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y I NTRODUCTION : This section of the owner’s manual is for the use of qualied technicians only . Fireplace placement, hearths, facing, mantles, and venting terminations will be covered, as wel l as the gas and electric systems.
Mount the two framing mount brackets on each side and secure the replace to framing with screws or nails (refer to Figure 7). The brackets will allow for a ” (13 mm), ” (16 mm), ” (19 mm) thick nishing wall. The w all may be nished up to the replace f acing with combustible material.
3" (76mm) 12" (305mm) 6" (152mm) 14" (356mm) T op of unit 3” (76mm) mantle 10" (254mm) mantle Combustible front face 3 / 4 " (19mm) facing board Figure 18. Combustible Mantle Clearances. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y 14 A shelf may be installed above the unit.
15 1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier .
16 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y V ENT P ARTS AND T ERMINAL C LEARANCES : The Sherwood Home Collection of replaces have been tested and certied for use with SIMPSON DURA VENT T YPE GS PIPE FOR GAS ST OVES.
When planning an installation, it is necessary to select the proper length of vent pipe for the particular requirements. The conguration of the venting pipes depends on the locations of walls, ceilings and studs. However , the pipes cannot be of arbitrary length and arrangement.
V e n t R e s t r i c t o r P o s i t i o n 20’ (6.10m) 25’ (7.62m) 30’ (9.14m) 32’ (9.75m) 41 3 / 4 ” (106cm) from floor 0’ (0m) 0’ (0m) 15’ (4.57m) 15’ (4.57m) 17’ (5.18m) 5’ (1.52m) 5’ (1.52m) 10’ (3.05m) 10’ (3.05m) Figure 23.
19 W all framing Horizontal wall termination W all thimble fire stop Exhaust flex pipe Combustion air outer pipe Elbow Initial Inst alla tion QUALIFIED INST ALLERS ONL Y H ORIZONTAL T ERMINATION : NOTES: 1.
20 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Step 3. T o install the R ound Support Box/W all Thimble in a at ceiling, cut a 10 inch (25.4 cm) square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 21.
21 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y STEP 5. Cut hole in the r oof centered on the small hole placed in the roof from Step 2. The hole should be of sufcient size to meet minimum requirements for Clearance to Combustibles, as specied.
NOTES: (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (914 mm), to avoid excessive stress on the elbows, and possible separ ation. W all straps are available for this purpose (see Figure 28).
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y I NSTALLATION O F E LECTRICAL W IRING F OR T HE O PTIONAL F AN K IT : Figure 31. Wiring Diagram For Gas Valve.
24 Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping ma y make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stov e is equipped with a certied exible pipe located on the right side of the unit terminating in a ” male NPT tting.
25 Figure 33: This is how the re box looks with only the grate and Optional Brick P anels in place. The burner has three (3) locator pins for the logs. Second ar y Inst alla tion L OG S ET AND E MBER I NSTALLATION : The placement of the logs is not arbitr ary .
Second ar y Inst alla tion Figure 36: The right log has two (2) holes in it that will rest over the two (2) locator pins pointed out in Figure 35. Figure 37: The front end of the right/center log has a notch in it that is to rest around the right/ center post of the gr ate.
27 Second ar y Inst alla tion Figure 39: Once the logs are in place the embers can be placed onto and around the burner to create a realistic look. Bags of ceramic ber embers and rock wool are provided. The cer amic ber comes in chunks that are about 2 inches (5.
28 Second ar y Inst alla tion O PTIONAL C ERAMIC B RICK P ANEL I NSTALLATION : Baffle Ledge Turn off the gas control knob and allow the unit to cool. Please ensure that your ceramic panels have not been damaged.
Second ar y Inst alla tion QUALIFIED INST ALLERS ONL Y O PTIONAL F AN K IT I NSTALLATION : The optional fan is thermostatically controlled and it will not operate if the appliance is cold. A few minutes after the appliance is lit and the variable speed control is set at a desired setting, the fan will automatically turn on.
Figure 48. Install Fan Control Box. Figure 49. Plug In Fan Kit. 30 Second ar y Inst alla tion Installation of Kit: 1. Ensure the appliance is turned off and cool. 2. Remo ve the bottom louv ers. 3. Place fan in lower area of unit behind the contr ols (see Figure 46).
T rouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor • Check connections to ignitor . • If ignitor connections are good but no spark, replace ignitor .
P ar ts List Reference Number Part Description Part Number 1 120°F Ceramic Fan T emperature Sensor EC-001 2 S.I.T . Nova V alve NG (50% turn down) EC-006 2 S.
33 P ar ts Diagr am .
W arr anty Sherwood Industries Ltd. offers a Limited Lifetime W arranty on this gas product. This Limited Lifetime W arr anty covers the appliance for a period of seven years from the date of installation. This warrant y applies only to the original owner in the original location.
35 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDR.
An important point after buying a device Enviro C-10791 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro C-10791 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro C-10791 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro C-10791 you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro C-10791 will certainly help you make a decision on the purchase.
If you already are a holder of Enviro C-10791, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro C-10791.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro C-10791. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro C-10791 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center