Instruction/ maintenance manual of the product C-10381 Enviro
Go to page of 48
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD OWNER’S MANUAL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE RE.
2 FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Car efully r ead all the instructions in this manual rst.
T able of Contents 3 Safety Precautions..................................................................................................................2 T able of Contents..............................................................................
4 DIRECT VENT ONLY: This type is identied by the sux DV . This appliance dra ws all of its air for combustion from outside the dwelling, through a specially designed v ent pipe system.
5 Specific a tions WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. D imensions : 16 5 / 8 " (42.2cm) 25 ¾" (65.3cm) 25 ¾" (65.
6 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.
7 2. Start the pilot by pressing the gas control knob and turning it to PILO T . While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 3).
8 Oper a ting Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating R emote contRoLs (o PtionaL ): This replace can use an optional remote control or an optional cordless wall thermostat.
Electronic ignition module Maintenance And Ser vice R outine m aintenance : At least once a year , run through the following procedures to ensure the system is clean and working properly . Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything.
Figure 6: Handles for Removing Door. Figure 7: Removing of Door. Maintenance And Ser vice R ePLacing the g Lass : The glass in the replace is a high temperature ceramic. If the glass is damaged in any wa y , a factory replacement is required (see P artS l iSt - c oMPonentS ).
11 Using a ½" deep socket remove/reinstall the main burner orifice. Undo the two (2) screws that hold burner in the firebox. Rotate handles and remove the door and glass. Lift off the pilot head and replace with proper pilot orifice for fuel type to be used.
12 Figure 9: Removing valve cap. Maintenance And Ser vice the HI/LO knob by hand shown in Figur e 9. Figure 11: Flip valve screw. Red o-ring is not visible Red o-ring is visible LPG Configuration b) I.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. P RePaRation F oR i nstaLLation : • Remov e the packaging f rom the appliance, and check to make sure there is no damage.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Vertical Termination Storm Collar Flashing Round Support Box/Wall Thimble Ceiling Firestop Pipelength Pipelength Cathedral Ceiling Support Box Pipele.
15 1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFP A 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the r equirements of the gas supplier .
16 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Wire spacers Figure 19: Wire Spacers. it to the inner wall fr ame using four (4) 1½” wood screws. If a wall is greater than 8” (203mm) in depth, the clearance above the ex must be 4⅜” (111mm) 6.
Flue Pipe Adaptor W all Framing W all Thimble Fire Stop Exhaust 4" Flex Pipe Combusion Air 6 5 / 8 " Flex Pipe Wire Spacers Horizontal V ent T ermination Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Figure 21: Installation of Fireplace Horizontal Vent Kit.
18 EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct V ent GS starting collar in conjunction with Secure V ent, Direct- T emp, and Ameri V ent Direct venting systems. Use of these systems with the Direct V ent GS starting col lar is deemed acceptable and does not affect the Intertek WH listing of the appliance.
1 2 3 4 5 View showing fully open restrictor plate View showing fully closed restrictor plate 1 2 3 4 5 Figure 22: Restrictor plate settings. The ENVIRO WESTPOR T has been designed wi th a built in restrictor plate.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y h oRizontaL i nstaLLation : 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached.
21 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Wood screws (x4) Cut vinyl siding away to fit standoff Bolt (x4) required Nut (x4) required Wood screw (x4) Figure 28: Installing Vent Cap with Vinyl Siding Stand-Off. Figure 29: Installing Horizontal Vent Termination.
3. T o install the R ound Support Box/W al l Thimble in a at ceiling, cut a 10” square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 30. 4 . Assemble the desired lengths of black pipe and elbows neces sary to reach from the appliance adapter up through the Round Support B o x.
23 the support straps that extend out bey ond the edge of the ashing. 7. Slip the ashing over the pipe section protruding thr ough the roof . Secure the base of the ashing to the roof with roong nails. Use a non-hardening sealant between the uphill edge of the ashing and the roof .
plumber ’s tape connected to wall strap W all strap 45° elbows (x2) Nails Ceiling firestop Ceiling Second floor Use clearances to as defined by appliance and vent pipe manufacturers. c atheDRaL c eiLing i nstaLLation : Figure 33: Use of Wall Straps.
25 Figure 36: Cathedral Ceiling Support Box Installation. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y 2 1 /2” (67 mm) Inside Wall Outside Wall 36” (915 mm) Snorkel Outside Wall Outside Wall 2 1 /2” (67 mm) Figure 37: Corner installation rear vented with snorkel.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y v enting into a c Lass ‘a’ c himney : This model is also certied and tested to vent into CL ASS ‘ A ’ wood stove chimneys. Place the freestanding direct v ent appliance in the desired location.
27 Firebox T op Flue Collar Adapter Undo four ¼" screws that hold flue collar elbow to unit. Figure 40: Step 3 of Converting Top Vented into Rear Vented.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y i nstaLLation oF t oP v enteD ; h oRizontaL t eRmination : Siding Exterior wall Drywall V ent pipe Inside finished collar W all thimble T ermination Figure 43: Installation for Top Vented; Horizontal Termination.
29 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y F ReestanDing D RaFthooD a DaPtoR - 50-841: This Dr afthood Adaptor is a complete assembly and is ready to t onto your W estport in a vertical vent application only . With the Drafthood Adaptor correctly installed and wired to the gas control valv e.
The minimum clear ance to combustibles is 6” (150 mm) when using single w all venting and 1” (25 mm) when using “B-v ent” venting. W e strongly recommend installing an approved chimney liner in an existing brick chimney . This will maximize the potential dr aft of the chimney and lessen the effects of slow chimney start -up.
31 Initial Inst alla tion AUTOMATIC SAFETY SHUT DOWN: If the spill switch is activ ated and shuts off the main burner the following procedure should be followed. • I s the pilot ame still on? If not, the reason for the replace shut down is not the spill switch.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y g as L ine c onnection anD t esting : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.
33 Figure 51: Gas Control Valve and Optional Thermostat Wiring. Initial Inst alla tion QUALIFIED INST ALLERS ONL Y e LectRicaL R equiRements F oR g as v aLve anD o PtionaL b LoweR : The ENVIRO WESTPOR T will operate without electrical power .
Fan assembly V alve cover Control panel (Fan control location) Screw hole Figure 53: Optional Blower (Fan) Installation. Second ar y Inst alla tion i nstaLLation oF o PtionaL b LoweR : 1. Remove the pre-assembled blower from the packaging. Inspect the blower for damage.
35 1. Carefully remov e logs from box. Check to ensure there is no damage. It is very important to install all logs in their proper position to insure safe, optimum operating conditions. 2. Place the log set into the rebox. Locate each log by seating it down onto the burner tra y support pins.
Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. Important note: When the unit is turned on for the rst time, It should be turned onto high without the fan on for the rst four (4) hours. This will cure the paint, logs, gasket material and the other products used in the manufacturing process.
37 Figure 63: Top brick panel in place, screws shown. Figure 64: Back brick panel in place. Figure 65: Side brick panels in place. Figure 62: Brick panel bracket, slots shown. 1. Remove the two (2) screws from the rear of the bafe, use a ¼” socket or a at head screwdriver .
38 T rouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temperature.
39 Reference Number Part Description Part Number 1 T op V ent Insert Piece - P ainted EGWP-503 1 T op V ent Insert Piece - Antique White EGWP-503A W 1 T op V ent Insert Piece - Diamond Black EGWP-503D.
Reference Number Part Description Part Number 5 Side P anel (Right) - P ainted EGWP-505 5 Side P anel (Right) - Antique White EGWP-505A W 5 Side P anel (Right) - Diamond Black EGWP-505DB 5 Side P anel.
Reference Number Part Description Part Number T op Complete ( T op, V ent Insert, & Grate) - P ainted EGWP-501 T op Complete ( T op, V ent Insert, & Grate) - Antique White EGWP-501A W T op Com.
42 P ar ts Diagr am - Cast 1 2 3 4 5 7 6 8 WESTPORT - Castings January 2005.
P ar ts List - Components Reference Number Part Description Part Number 9 120° Cer amic F an T emperature Sensor EC -001 10 S.I.T . Nova V alve Con vertible 50-1421 11 Thermocouple EC -009 11 Spark E.
P ar ts List - Components Reference Number Part Description Part Number 19 Inner Door Handles (2 per set) 30-052 20 V enturi Adjustment Rod 30-053 21 Firebox 30-054 22 P an Burner Only 30-055 23 45° Elbow & Gasket 50-040 24 F an Kit 180 C.
45 P ar ts Diagr am - Components 13 17 16 10 27 15 26 24 9 22 11 21 25 29 20 14 19 23 12 28 18 WESTPORT - Components January 2005.
46 W arr anty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest lev el of quality and customer service is the most important thing we do.
47 caused by mechanical systems such as furnaces, f ans, clothes dryers etc. 12. The Limited W arrant y is void if: a) The stove has been oper ated in atmospheres contaminated by chlorine, uorine or other damaging chemicals. b) The stove is subject to submersion in w ater or prolonged periods of dampness or condensation.
48 Inst alla tion Da t a Sheet The following information must be recorded by the installer for warrant y purposes and futur e reference. NAME OF OWNER: _________________________________________ ADDRES.
An important point after buying a device Enviro C-10381 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro C-10381 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro C-10381 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro C-10381 you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro C-10381 will certainly help you make a decision on the purchase.
If you already are a holder of Enviro C-10381, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro C-10381.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro C-10381. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro C-10381 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center