Instruction/ maintenance manual of the product 50-830 Enviro
Go to page of 14
50-830 PELLET ST OVE MERIDIAN SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY .
2 Introduction..............................................................................................................3 P ellet Quality ..................................................................................................3 Automatic Safet y Features.
3 Introduction * This manual is designed for the home owner in conjunction with the technical manual. * P ELLET Q UALITY : Pellet quality is important, please read the following: Your enviro pellet stove has been designed to burn wood pellets only. Do not use any other type of fuel, as this will void any warranties stated in this manual.
4 I MPORTANT S AFETY D ATA : P lease read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
5 ASHES: Disposed ashes should be placed in a metal container with a tight-fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal.
6 32 1 / 2 " (826mm) 24 7 / 8 " (632mm) 24 3 / 4 " (629mm) Introduction D IMENSIONS - F REESTANDING : Figure 1: Meridian Freestanding Dimensions. 23 3 / 4 " (604mm) 12 7 / 8 " (326mm) 22 7 / 8 " (583mm) 23 7 / 8 " (605mm) Figure 2: Meridian Fireplace Insert Dimensions.
7 Oper a ting Instructions C ONTROL B OARD F UNCTIONS : 1. AUGER TRIM: Used to change feed rates on LOW ONL Y for poorer quality fuels. Push the Auger T rim button until the number 1 and 5 lights appear on the Heat Lev el Indicator . This will incr ease the feed rate to four (4) seconds ON time Auger pulse.
8 Oper a ting Instructions O PERATING Y OUR P ELLET S TOVE : PRE-BURN INSTRUCTIONS : The burn pot liner holes must be clear and the liner installed correctly against the ignitor tube for proper oper ation. Check the hopper for enough pellets to start the unit.
9 Oper a ting Instructions S LIDER / D AMPER S ETTING : THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION. A Qualified Service Technician or Installer must set the Slider Damper . The combustion exhaust blower is a variable speed blower controlled by the heat output button.
2-3 Days / Weekly Semi-annually or 2 T ons of Fuel Burn Pot and Liner Exhaust V ent Ash Pan Fresh air Intake T ube Inside Firebox Blower Mechanisms Door Glass Heat exchanger tubes Heat exchanger tubes.
FRESH AIR INTAKE (season) Inspect periodically to be sure that it is not clogged with any f oreign materials. EXHAUST VENT (season) This vent should be cleaned every year or after two (2) tons of pel lets. W e recommend contacting your dealer for professional cleaning.
12 EXHAUST PASSAGES (season) Removal of the firebox backing for bi- annual cleaning (refer to Figure 8): • Open the door by lifting the handle, remove the burn pot and burn pot liner . • Lubricate all screws with penetrating oil. • Remov e the four (4) screws that hold the brick liner retainers in place.
13 W arr anty Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-year warr anty is provided on all electrical components.
14 The following information must be recorded by the installer for warr anty purposes and future r eference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________.
An important point after buying a device Enviro 50-830 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro 50-830 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro 50-830 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro 50-830 you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro 50-830 will certainly help you make a decision on the purchase.
If you already are a holder of Enviro 50-830, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro 50-830.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro 50-830. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro 50-830 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center