50-1578 TECHNICAL MANU AL PELLET ST OVE WINDSOR SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER.
2 T able of Contents Safety W arnings & R ecommendations.........................................................................3 Installation........................................................................................................
3 Safety W arnings & Recommend a tions * This manual is designed for the technician in conjunction with the owner’s manual. * Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
4 Safety W arnings & Recommend a tions CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will v ary due to the ash content of the f uel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi- annually or every two tons of pellets.
5 Safety W arnings & Recommend a tions FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “ Air Tight Homes” or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly .
Inst alla tion R ATING L ABEL L OCATION : The rating label is located on the back of the hopper . D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles (see I NSTALLATION - C LEAR ANCES TO C OMBUSTIBLES and I NSTALLATION - A LCOVE C LEARANCES ).
7 Figure 2: Windsor Dimensions. 27 1 / 8 " (689mm) 25 3 / 4 " (653mm) 25 7 / 8 " (659mm) 15 3 / 8 " (390mm) 14 1 / 4 " (360mm) 24 1 / 8 " (614mm) Inst alla tion D IMENSIONS & S PECIFICATIONS : T able 1: Windsor Specifications.
This unit may be installed in an alcove. Maintain the clearances to combustibles shown in Figur e 4. Minimum Alcove width 1220mm (48 inches) Minimum Alcove height 1220mm (48 inches) Maximum Alcove depth 915mm (36 inches) Install vent at clearances specified by the vent manufacturer.
9 hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust above the inlet elev ation.
10 10 1 / 2 ” (265 mm) 8 1 / 2 ” (216 mm) 12 7 / 8 ” (326 mm) 8 3 / 8 ” (214 mm) 4 3 / 8 ” (1 12 mm) EXHAUST Base of unit to center of flue 270 mm (10 ”) Side of unit to center of flue 308 mm (12 ”) Center of unit to center of flue 19 mm (”) FRESH AIR INTAKE.
11 Figure 8: Corner Installation. 100mm (4") 100mm (4") Fresh Air Intake W all thimble manufactured by pellet vent manufacturer . Inst alla tion C ORNER T HROUGH W ALL I NSTALLATION : H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION : Vent installation: install vent at clearances specified by the vent manufacturer.
Exhaust 80mm (3") or 100mm (4") Vent Pipe Wall Thimble 45 o Elbow with Screen or Termination Cap High Temperature RTV Silicone Required Fresh Air Intake Wall framing Wall thimble Termination.
13 Inst alla tion V ERTICAL R ISE WITH H ORIZONTAL T ERMINATION I NSTALLATION (R ECOMMENDED ): A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).
Storm Collar Roof Flashing Roof Rafters Fire Stop with Support Collar Ceiling Joist Vertical Vent Pipe Clean Out Tee with Pipe Adapter ENVIRO Windsor Note: All vent sections must maintain 3" (75mm) clearances to combustibles.
15 Inst alla tion O UTSIDE V ERTICAL I NSTALLATIONS : T o accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “ I NSIDE V ERTICAL I NSTALLATIONS - F REESTANDING ” section and then finish it by performing the f ollowing (refer to Figure 14).
Storm Collar Existing Masonary Flue Flexible Vent Connector (use this 1.5m (5ft) section of pipe to vent past the fireplace damper or smoke shelf) Seal Plate Fireplace Damper Location Vertical Vent Pi.
17 Install blower motor onto exhaust blower housings. Completed assembly. Exhaust Motor Cover Plate Access Panel Inst alla tion I NSTALLATION WITH E XTERIOR M OUNTED E XHAUST B LOWER : The WINDSOR can be equipped with an externally mounted exhaust blower (PAR T #50-492).
TO SUPPLY POWER TO THE EXHAUST BLOWER: Install an amour coated electrical cable from the exhaust blower housing, thr ough the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar . Hook up to wires fr om the wiring harness for the exhaust blower .
19 Storm Collar Roof Flashing Roof Rafters Roof Sheathing Ceiling Joist Vertical Vent Pipe Outside Vent Termination Exterior Wall Sheathing Rain cap - ensure cap is at least 900mm (3 ft) above the roo.
S LIDER /D AMPER S ETTING : THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE THE AIRFLOW THROUGH THE PELLET STOVE. A Qualified Service Technician or Installer must set the Slider Damper .
21 • A tall, lazy flame with dark orange tips r equires more air – Open slider (pull out) slightly . • A short, brisk flame, like a blowtorch, has too much air – Close slider (push in) slightly .
T roubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. ● Do not remove from the firebox any screws without penetrating oil lubrication.
23 T roubleshooting ü Check vacuum levels in the exhaust channel by bypassing the vacuum switch, then remove the vacuum hose from vacuum switch. Check exhaust vacuum readings by placing the open end of the vacuum hose on a Magnahelic Gauge (readings must be above 0.
T roubleshooting ü If the auger gear box does not turn but the motor ’ s armature does try to spin then the auger is jammed. – T ry to break apart jam by poking at the jam through the drop tube.
25 W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White White White Orange Orange Orange Orange Yellow Yellow Grey Grey Purple Purple Blue Black Bla.
Reference Number Description Part Number 1 120 °F (49 °C) Ceramic F an T emperature Sensor EC -001 2 Auger Motor - 220V EF-001-220V 3 High Limit T emp Sensor 200 °F (93 °C) Manual Reset EF-016 Sil.
27 Reference Number Description Part Number Auger Motor Mount 50-687 Auger Plate with bushing 50-688 Auger Mounting Hardwar e 50-689 22 IEC Power Cor d Inlet Socket 50-713 Hinge Pin - Silver 50-750 Ov.
P ar ts List - Cast Reference Number Description Part Number 41 Cast Ash Shelf - P ainted 50-192 42 Cast Front Complete (Doors & Ash Shelf ) - Painted 50-202 43 Cast Side Left - P ainted 50-203 44.
WINDSOR - Components May 2007 P ar ts Diagr am - Components 29.
WINDSOR - Steel & Cast May 2007 .
31 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE.
An important point after buying a device Enviro 50-1578 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Enviro 50-1578 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Enviro 50-1578 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Enviro 50-1578 you will learn all the available features of the product, as well as information on its operation. The information that you get Enviro 50-1578 will certainly help you make a decision on the purchase.
If you already are a holder of Enviro 50-1578, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Enviro 50-1578.
However, one of the most important roles played by the user manual is to help in solving problems with Enviro 50-1578. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Enviro 50-1578 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center