Instruction/ maintenance manual of the product BF-20-2 Empire Comfort Systems
Go to page of 20
INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED ROOM HEA TER MODELS BF-10-2 BF-20-2 BF-30-2 W ARNING: If not installed, operated and ma in ta in ed in acc or da nc e with the man uf ac tu r - er's instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness.
16943-7-0907 Page 2 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas .............................
16943-7-0907 Page 3 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom.
16943-7-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can af fect your sensitivity or ability to detect that odor .
16943-7-0907 Page 5 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equip - ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency .
16943-7-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 Btu (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house).
16943-7-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
16943-7-0907 Page 8 SRS-18* and SRS-30 Floor Stand Installation 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 5. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line.
16943-7-0907 Page 9 On Sheet Rock W all 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) plastic expansion anchors provided into the holes. 3. T ighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors.
16943-7-0907 Page 10 T O TURN OFF GAS T O APPLIANCE 1. STOP! Read the safety information above. 2. Set thermostat (gas control knob) to lowest setting. 3. T urn off all electric power to the appliance (if applicable). 4. Push in gas control knob slightly and turn clockwise to "OFF".
16943-7-0907 Page 1 1 Piezo Pilot Ignitor Instructions Depressing the ignitor button completely causes a spark to occur at the pilot. T o light the pilot, it is important that the electrode be 1/8" (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple.
16943-7-0907 Page 12 The correct flame will be blue and will extend beyond the thermo- couple. The flame will surround the thermocouple just below the tip.
16943-7-0907 Page 13 Glass Removal, Cleaning and Glass Replacement 1. Remove chrome grill from reflector . 2. Slide glass upward to remove glass from chrome grill. 3. Clean glass with a non-abrasive household glass cleaner and warm water . Gas fireplace glass cleaner can also be used.
16943-7-0907 Page 14 1. Spark electrode does not pr oduce spark. a. Spark electrode broken - replace. b. Ignitor wire ma y not be attache d to spa rk elect rode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode pr oduces spark but pilot does not light.
16943-7-0907 Page 15 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS.
16943-7-0907 Page 16 P AR TS VIEW.
16943-7-0907 Page 17 INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on SRS-18 or SRS-30 optional floor stand there is adequate access area available to install the optional blower .
16943-7-0907 Page 18 P ARTS LIST Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri- cal Code, ANSI/NFP A 70, if an external electrical source is utilized.
16943-7-0907 Page 19 SER VICE NOTES.
16943-7-0907 Page 20 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
An important point after buying a device Empire Comfort Systems BF-20-2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Empire Comfort Systems BF-20-2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Empire Comfort Systems BF-20-2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Empire Comfort Systems BF-20-2 you will learn all the available features of the product, as well as information on its operation. The information that you get Empire Comfort Systems BF-20-2 will certainly help you make a decision on the purchase.
If you already are a holder of Empire Comfort Systems BF-20-2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Empire Comfort Systems BF-20-2.
However, one of the most important roles played by the user manual is to help in solving problems with Empire Comfort Systems BF-20-2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Empire Comfort Systems BF-20-2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center