Instruction/ maintenance manual of the product PN 51A-499ACL01/rev.K Emerson
Go to page of 8
Model 499A CL-01 F ree Chlorine Sensor Instruction Sheet PN 51A-499ACL01/rev .K September 2010 SPECIFICA TIONS - SENSOR Pressure: 0 to 65 psig (0 to 549 kPa abs) T emperature: 32 to 122°F (0 to 50°C.
2 MODEL 499A CL-01 INST ALLA TION FIGURE 4. Low Flow Cell (PN 24091-00 or 24091-01) INST ALLA TION Install the sensor in a flowing sample. Keep the sample flow as constant as possible at a value within the limit s below . Flow through 1 to 5 gpm (3.8 to 19 L/min) Open channel 1 ft/sec (0.
MODEL 499A CL-01 WIRING WIRING 3 FIGURE 5. Wiring Sensor with St andard Cable to Model 1056 and Model 56 Analyzer FIGURE 6. Wiring Sensor with Optimum EMI/RFI or V ariopol Cable to Model 1056 and Model 56 Analyzer FIGURE 7. Wiring Sensor with St andard Cable to Model 54eA Analyzer FIGURE 8.
FIGURE 9. Wiring Sensor with St andard Cable to Model 5081-A T ransmitter . FIGURE 10. Wiring Sensor with Optimum EMI/RFI or V ariopol Cable to Model 5081-A T ransmitter . FIGURE 1 1. Wiring Sensor with Standard Cable to Model Xmt-A T ransmitter . FIGURE 12.
FIGURE 13. Wiring Sensor with St andard Cable to Model 1066 T ransmitter . FIGURE 14. Wiring Sensor with Optimum EMI/RFI or V ariopol Cable to Model 1066 T ransmitter . CALIBRA TION Zero point: Even in the absence of free chlorine, the 499ACL-01 sensor generates a small signal called the zero current.
MODEL 499A CL-01 MAINTENANCE MAINTENANCE CLEANING THE MEMBRANE. Keep the membrane clean and free from dirt and algae. Clean the membrane with water sprayed from a wash bottle. Do not use tissues to clean the membrane. REPLACING THE ELECTROL YTE SOLUTION AND MEMBRANE.
33523-00 Electrolyte Fill Plug 9550094 O-Ring, Viton 2-014 33521-00 Membrane Retainer 23501-08 Free Chlorine Membrane Assembly: includes one membrane assembly and one O-ring 23502-08 Free Chlorine Membrane Kit: includes 3 membrane assemblies and 3 O-rings 9210356 #4 Free Chlorine Sensor Fill Solution, 4 oz (120 mL) SP ARE P ARTS FIGURE 16.
Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .raihome.com Specifications subject to change without notice. 8 Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .
An important point after buying a device Emerson PN 51A-499ACL01/rev.K (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson PN 51A-499ACL01/rev.K yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson PN 51A-499ACL01/rev.K - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson PN 51A-499ACL01/rev.K you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson PN 51A-499ACL01/rev.K will certainly help you make a decision on the purchase.
If you already are a holder of Emerson PN 51A-499ACL01/rev.K, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson PN 51A-499ACL01/rev.K.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson PN 51A-499ACL01/rev.K. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson PN 51A-499ACL01/rev.K along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center