READ AND SA VE THESE INSTRUCTIONS Part No. F40BP73610000 Form No. BP7361 U.L. Model No.: CF3100 Net Weight: 26.0 Lbs. Model Numbers DUNNINGT ON ™ Ceiling F an Owner's Manual CF3100A GW00 Aged W.
2 WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference 2 .
3 This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan One stepladder One wire stripper One Phillips head screwdriver Three 15-watt (max.) candelabra base bulbs (not supplied) MA TERIALS Wiring outlet box and box connectors must be of type required by the local code.
1. Place the flange assembly onto the blade. Place the flange medallion assembly into the three holes on the opposite side of the blade. 2. Secure the flange assembly and flange medallion to the blade using the three M5 x 12mm pan head screws and three lockwashers.
7. Connect the 4-pin connector from the decorative light kit assembly to the 4-pin connector of the switch housing (Figure 3). 8. Connect the switch housing blue wire single-pin connector to the black.
22. 16” Or Optional Longer Downrod Installation: Slide the decorative scrolls over the 16” downrod to rest upon the decorative upper housing (Figure 9) To secure the decorative scrolls to the downrod, tighten the Philips head screw in the decorative scroll collar.
7 Ho w to Hang Y our Ceiling F an FLOOR CEILING A T LEAST 7' Figure 11 The fan must be hung with at least 7' of clearance from floor to blades (Figure 11). Do NOT hang this fan on an 8’ ceiling. WARNING 1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 12).
8 OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW F AN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE.
1-1/4" THREADED STUD (2) CEILING COVER KNURLED KNOB (2) LOCKWASHER (2) HANGER BRACKET OUTLET BOX HANGER BALL/DOWNROD ASSEMBL Y 1-1/4" THREADED STUDS (2) HANGER BRACKET OUTLET BOX RECEIVER CE.
LIGHT KIT ASSEMBL Y LIGHT KIT SOCKET 50-WA TT (Max.) BI-PIN HALOGEN BULB (T ype GY8) 10 2. Place the glass onto the light kit assembly aligning the three flat areas on the top flange of the glass shade with the three pins on the inside of the assembly (Figure 19).
The SW116 wall control transmits the command signals via radio waves to the SW105 receiver installed in the ceiling fan ceiling cover. The SW105 receiver is required for the SW116 wall control to function. Power for the SW116 wall control comes from the 12V battery, located in the wall control.
Operating Y our Ceiling F an IMPORT ANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Your SW116 Fan/Light Wall Control (Figure 24) has full control of your fan, lights, and airflow direction.
13 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line connections to the fan.
14 1 8 9 10 3 2 7 5 17 31 18 19 4 6 21 11 24 23 12 22 26 27 28 15 16 30 25 14 29 H I H I M E D M E D L O W L O W F A N O F F R E V R E V L I G H T 32 20 13 13 R epair P ar ts U.
15 R epair P ar ts Listing Key Model Numbers N o . Description CF3100AGW00 CF3100BZH00 * Hanger Pack, Consisting of: 761655-71 761655-70 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod - 16.
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Printed in China 01/08 Form No. BP7361 Part No. F40BP73610000 U.L. Model No.: CF3100 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co.
An important point after buying a device Emerson CF3100AGW00 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson CF3100AGW00 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson CF3100AGW00 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson CF3100AGW00 you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson CF3100AGW00 will certainly help you make a decision on the purchase.
If you already are a holder of Emerson CF3100AGW00, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson CF3100AGW00.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson CF3100AGW00. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson CF3100AGW00 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center