Model 499A OZ Ozone Sensor Instruction Sheet PN 51A-499AOZ/rev .H September 2010 SPECIFICA TIONS - SENSOR Pressure: 0 to 65 psig (101 to 549 kPa abs) T emperature: 32 to 122°F (0 to 50°C) Process Co.
2 MODEL 499A OZ INST ALLA TION INST ALLA TION FIGURE 1. Sensor Orient ation FIGURE 2. Flow-Through 2 in. T ee FIGURE 3. Flow-Through 1-1/2 in. T ee Flow through 1 to 5 gpm (3.8 to 19 L/min) Open channel 1 ft/sec (0.3 m/sec) Low flow cell 2 to 5 gph (7.
MODEL 499A OZ WIRING WIRING 3 FIGURE 5. Wiring Sensor with St andard Cable to Model 54eA Analyzer FIGURE 6. Wiring Sensor with OptimumEMI/RFI or V ariopol Cable to Model 54eA Analyzer FIGURE 7. Wiring Sensor with St andard Cable to Model 1056 and Model 56 Analyzer FIGURE 8.
FIGURE 9. Wiring Sensor with St andard Cable to 5081-A T ransmitter . FIGURE 10. Wiring Sensor with Optimum EMI/RFI or V ariopol Cable to 5081-A T ransmitter . MODEL 499A OZ WIRING FIGURE 12. Wiring Sensor with Optimum EMI/RFI or V ariopol Cable to Xmt-A T ransmitter .
FIGURE 13. Wiring Sensor with St andard Cable to Model 1066 T ransmitter . FIGURE 14. Wiring Sensor with Optimum EMI/RFI or V ariopol Cable to Model 1066 T ransmitter . CALIBRA TION Zero point: Even in the absence of ozone, the 499AOZ sensor generates a small signal called the zero current.
MAINTENANCE CLEANING THE MEMBRANE. Keep the membrane clean and free from dirt. Clean the membrane with water sprayed from a wash bottle. Use a soft tissue to gently wipe the membrane. REPLACING THE ELECTROL YTE SOLUTION AND MEMBRANE. 1. Unscrew the membrane retainer and remove the membrane assembly and O-ring.
33523-02 Electrolyte Fill Plug 9550094 O-Ring, Viton 2-014 33521-02 Membrane Ret ainer 23501-1 1 Ozone Membrane Assembly: includes one membrane assembly and one O-ring 23502-1 1 Ozone Membrane Kit: includes 3 membrane assemblies and 3 O-rings 9210299 #3 Ozone Sensor Fill Solution, 4 oz (120 mL) SP ARE P ARTS FIGURE 16.
MODEL 499A OZ ORDERING INFORMA TION Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .
An important point after buying a device Emerson 499A OZ (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Emerson 499A OZ yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Emerson 499A OZ - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Emerson 499A OZ you will learn all the available features of the product, as well as information on its operation. The information that you get Emerson 499A OZ will certainly help you make a decision on the purchase.
If you already are a holder of Emerson 499A OZ, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Emerson 499A OZ.
However, one of the most important roles played by the user manual is to help in solving problems with Emerson 499A OZ. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Emerson 499A OZ along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center