Instruction/ maintenance manual of the product 014003051-00 EMC
Go to page of 26
1 This d ocum ent explai ns h ow to conve rt a Mode l FC4 700 s torag e sys tem to a Model IP4 700 file server by replacing and initializing the storage process ors (SPs), loading IP4700 s oftware, a nd completing a Factory Initializat ion procedure. T opics are: • Requirem ents .
2 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Requirements Requirem ents The IP4700 file server supports twisted-pair CA T5 copper Ethernet and/or optical Ethernet cables.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 3 Requirements IP4700 Dis k Rules The following rules define IP47 00 disk driv e configuration s: Ta b l e 1 Supported Disks in DPE and D AEs • Y ou cannot mi x disk sizes or sp indle sp eeds with in IP4 700 syste m shelves .
4 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Con version Kit(s) Con v er sion Kit(s) The FC470 0-to-IP 4700 with Qu ad LAN Co nversion K it ( FC-IP 4700F ) conta ins t he fo l.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 5 Conv erting the Hardw are Con v er ting the Hardw are CAUTION ! The follo wing proced ure assumes tha t you have approp riately backed up or moved to another storage system any data you want to preserve.
6 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Con verting the Hardw are Mo ve the FC4700 Syste m Drives to Data-Only Loca tions 7. Ensure th at the DPE is configured with 10 disk s of the same size and sp eed. Suppo rted disks and co nfigu rati ons are liste d on page 3 of th is document.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 7 Loading IP4700 Software Loading IP4700 Softw a re The steps in this section g uide you through the firm ware/software loading process. They begin wi th verifying and , if necessary , flashing new firm ware to each storage process or .
8 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Loading IP4700 Softw a re If necessary , refer to ch apter 3 in the IP4700 Installat ion and Service Guide fo r instructions on removing and in stalling dis k drives. 4. Remove th e disk drive installed in DPE slot 0 (th e leftmost slo t) and set it aside.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 9 Loading IP4700 Software 9. Repeat step 7 f or the second SP , upgrading PROM or BIOS if necess ary . If y ou did not upgrade PR OM or BIOS in the preceding steps , continue with step 10.
10 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Loading IP4700 Softw a re 1 1. At the FS > prompt, type dsktodsk 0,1 and then press <En ter> . This copies the image fr om the seed disk (0) to disk 1 in appr oximat ely t en seconds.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 11 Loading IP4700 Software Note: If you see the error messag e: disk 2 not on the loop, e nsur e that th e disk 2 LED is on solid and r epeat Step 15 befor e trying a g ain.
12 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization F ac tor y Initialization Factory init ializati on is a process that al l new IP4700 sy stems experience prior to shipment.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 13 Factory I nitialization Once the IP4700 banner is displayed, you have a maximu m of 60 secon ds to enter ^V .
14 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization 6. When you see the Boot Console menu, type 2 at the Enter Number of Your Choice: field, and then press <Enter> to r e ach the fcli co mmand lin e.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 15 Factory I nitialization V erify System Stat us 7. A t the fcli > prompt, type ls and then press <En ter> . Note: I f the displ ay indicates b ound LU Ns, you have “ sta le data ” on disk 0.
16 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization 9. Exam ine the SPST A T information carefully . V e rify the follow ing: – the PEER SP is PRESENT – the SPS units ar e in one of the fo l lowing states: TE, NR, or OK.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 17 Factory I nitialization 1 1. On the second scr een of SPST A T information, verify the followi ng: – The system sees all the disk drives a nd they ar e unbound. – The system se es all power sup plies and fa n modules a nd they are OK.
18 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization 14. At the fcli> prompt, t ype spstat and then press <Enter> . V erify that a ZER has replaced the UNB . 15. At the fcli> prompt, type getlog and then press <Enter > .
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 19 Factory I nitialization 16. At the fcli> prompt, type clea r log a nd then press <Enter> . 17. On ce ALL the disk LED s have stopped f l ashing, type getlog at the fcli> prompt an d th en pr es s <Enter> .
20 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization 18. At the fcli> prompt, type clearlog and then pr ess <Enter> . fcli> getlog ↵ Press any key to continue... (or “ q ” to Quit) ↵ Event Date CRU Event (Message) Extended Status 0.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 21 Factory I nitialization Load DPE Chassis Ser ial Number 19. At the fcli> prompt, type setser serial number and then pr ess <Enter> .
22 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization 23. At the fcli > prompt, type setse r and then pr ess <Enter> . 24. V erify that you entered the serial number accurately . If the serial number is incorrect, repeat Steps 19 th rough 23.
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 23 Factory I nitialization Perf or m the Factor y Initialization 27. Perf orm the Fa ctory Initi alization process: a. A t the Enter Number of Your Choice: prompt, type 1 and then press < Enter>.
24 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization 28. When the in itializatio n completes, press <Enter> t o r ebo ot the system. Reboot time is approximately 5 minutes. When the system finishes booti ng, it displays th e IP4700 banner and a r e quest to Press Enter to continue .
Fibre Channel FC 4700 Array to IP4700 File Ser ver Conv ersi on Guide 25 Factory I nitialization The conversion fr om an FC4700 to an IP4700 is now complete. Perf orm the Site Initialization Next you mus t launch the IP4 700 Initia lization W iza rd (sometimes called the Setup W izard).
26 Fibre Channel FC470 0 Array to IP4700 File Server Conversion Guid e Factory Initialization Syste m In stalla tion 30. T o install the new system, follow the instructions in the IP4 700 Quick Start Guide, the on-line wizar d instructions, and the IP4700 Release Notes for your software r evision.
An important point after buying a device EMC 014003051-00 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought EMC 014003051-00 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data EMC 014003051-00 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, EMC 014003051-00 you will learn all the available features of the product, as well as information on its operation. The information that you get EMC 014003051-00 will certainly help you make a decision on the purchase.
If you already are a holder of EMC 014003051-00, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime EMC 014003051-00.
However, one of the most important roles played by the user manual is to help in solving problems with EMC 014003051-00. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device EMC 014003051-00 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center