Cello Digital Servo Drive Cable Kits Main Feedback: CBL-DFDBK (general purpose) CBL-DFDBK-5 Encoder: CBL-MTRENC2 (for SAR, SA,SB,SC) CBL-MTRENC2-5 Encoder: CBL-MTRENC4 (for SE) CBL-MTRENC4-5 Aux. Feedback: CBL-CELAUX -5 CBL-CELAUX-5 General I/O: CBL-CELIO1 -5 (J1) CBL-CELIO1-5 General I/O: CBL-CELIO2 -5 (J2) CBL-CELIO2-5 Aux.
Important Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary informatio n belonging to Elmo Motion Control Ltd. Such information is supplied solely for the purpose of assisting users of Elmo’s Cello servo drives in assembling the required cables for their drive.
Contents 1. Introduct ion ................................................................................................................ ............. 1 1.1 Cello Connectors ...........................................................................
1. Introduction This document provides the wiring details fo r the cables used to connect Cello digital servo drives with the end-user application. The servo drive-side pinouts are provided in Chapter 3 of the drive’s installation guide. The cables come in two lengths: 2 meters (6 ½ feet) and 5 meters (16 ½ feet).
Type Function Port Connector Location 8-pin RJ-45 CANopen CAN 8-pin RJ-45 CANopen CAN 15-pin D-Sub (high-density) Feedback B Feedback B 8-pin RJ-45 RS-232 RS-232 Table 1-3: The Cello’s Communications and Feedback B Connectors 1.2 Cable Cross-Reference Cable Application Cable Part.
2. Cable Kits Several Cable Kits can be purchased from Elmo. Each contain a set of 8 cables. The -5 suffix on the kits and on the cables (CBL-DFDBK-5 fo r example) indicate that the cables are 5m long. Cables and kits without that suffix are 2m long (except for CBL-RJ45CAN2 which is 20cm long).
3. Main Feedback Cables The main feedback cables are made of 24-AWG sh ielded cable. There are 3 types of feedback cables, all use a 15-pin D-sub plug which connects to the FEEDBACK A port on the Cello. • The General-Purpose Main Feedback Cable (CBL-DFDBK) is open on the motor side so that it can be connected to customer-specific connectors.
3.2 Encoder Cable (CBL-MTRENC2 -5 for SAR, SA, SB, SC) D-Type Pin No. Color Socket Pin No. Signal Pair Description 1 10 Green Yellow 11 9 HC HB pair Hall sensor C input Hall sensor B input 2 Pink 7 HA.
3.3 Encoder Cable (CBL-MTRENC4 -5 for SE) D-Type Pin No. Color Socket Pin No. Signal Description 1 Green P HC Hall sensor C input 10 Yellow M HB pair Hall sensor B input 2 Pink K HA Hall sensor A inpu.
4. Auxiliary Feedback Cable (CBL-CELAUX -5) The auxiliary feedback cable is a 24-AWG shielded cable. It is connected using an 15-pin Hi-density D-sub plug which connects to the Cello’s FEEDBACK B port.
5. General I/O J1 (CBL-CELIO1 -5 ) The digital input cable is a 24-AWG shielded cable. It is connected using an 15-pin Hi- Density D-sub socket. Pin Color Signal Pair Function Pin Position 1 Orange IN.
6. General I/O J2 (CBL-CELIO2 -5 ) The digital output cable is a 26-AWG shielded cable. It is connected using a 15-pin Hi- Density D-sub plug. Pin Color Signal Pair Function Pin Position 1 Orange IN5 .
7. Auxiliary Power Cable (CBL-CEL24 -5 ) The auxiliary power cable is a 24-AWG shie lded cable terminated by pins on the SimplIQ side. The pins are screwed into the 2-pole Pheonix Terminal Block provided with the Cello.
8.2 Motor Power Cable (CBL-MTRPWR1CEL -5 ) CBL-MTRPWR1CEL -5 is a 24-AWG shielded cable in which each wire, on the SimplIQ drive side, is connected to a pin terminal and the wires on the motor side are connected to a 4-pole socket. This cable is designed for connecting a Cello to a Metronix APM-SAR, SA, SB or SC motor.
9. Communication Cables The communication cables use 26-AWG twisted pair shielded cable. They are connected using an 8-pin RJ-45 plug. Elmo drives can communicate using the following options: RS-232, full duplex CANopen 9.1 RS-232 Option (CBL-RJ452321 -5 ) RJ45 Pin No.
9.2 CAN Option (CBL-RJ45CAN1 -5 ) RJ45 Pin No. Color D-type Female Pin No. Signal Description 1 Green 7 CAN-H CAN_H bus line 2 Yellow 2 CAN_L CAN_L bus line 3 White 3 CAN_GND CAN ground 4 — — — .
9.3 CAN Option (CBL-RJ45CAN2) Cable CBL-RJ45CAN2 is 20 cm long, it is used for “daisy-chaining” CAN nodes. On the Harmonica this cable is connected to the External Dual Can Port.
An important point after buying a device Elmo CBL-DFDBK (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Elmo CBL-DFDBK yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Elmo CBL-DFDBK - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Elmo CBL-DFDBK you will learn all the available features of the product, as well as information on its operation. The information that you get Elmo CBL-DFDBK will certainly help you make a decision on the purchase.
If you already are a holder of Elmo CBL-DFDBK, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Elmo CBL-DFDBK.
However, one of the most important roles played by the user manual is to help in solving problems with Elmo CBL-DFDBK. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Elmo CBL-DFDBK along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center