BS EN 50291: 2001 MAINS MAINS POWERED POWERED Model Ei 225EN Model Ei 220EN - HARD WIRED T O MAINS - WITH PO WER CORD MAINS PO WERED CARBON MONO XIDE ALARM Read and retain carefully f or as long as the product is being used. It contains vital inf or mation on the operation and installation.
3 4 5 11 15 19 20 22 24 26 28 28 30 1 2 3 4 5 6 7 8 9 10 11 12 13 READ THIS FIRST WHA T T O DO WHEN THE CO ALARM SOUNDS CARBON MONO XIDE - THE SILENT KILLER! WHERE T O PLA CE CARBON MONO XIDE ALARMS I.
1. READ THIS FIRST W ARNING: The Ei225EN Alar m should be permanently wired to the mains by a qualified electrician in accordance with IEE wir ing regulations (BS7671).
When the CO Alar m detects abnormal lev els of CO (abov e 50ppm CO) the red light star ts to flash and the horn will sound within 90 minutes. At higher le vels of CO the alar m will turn on sooner (see table B - page 9). The CO Alar m will automatically reset once the CO has cleared.
(5) Ring your gas or other fuel supplier on their emergency n umber . K eep the number in a prominent place . (6) Do not re-enter the proper ty until the alarm has stopped. (If the alar m has been silenced by pressing the test/hush b utton, wait at least 5 minutes so the alarm can check that the CO has cleared).
(CO) poisoning. CO is an invisible , odour less , tasteless and extremely to xic gas. It is produced by appliances and v ehicles burning fuels, such as coal, oil, natural/bottled gas, paraffin, w ood, petrol, diesel, charcoal etc.
7 Mild Exposure : Slight headache, nausea, v omiting, fatigue (often described as “flu-like” symptoms). Medium Exposure : Se vere throbbing headache , drowsiness, confusion, f ast hear t rate . Extreme Exposure : Unconsciousness, con vulsions, cardiorespiratory failure, death.
T able A: Effects of Carbon Mono xide P oisoning 35 The maximum allow able concentration f or continuous exposure in any 8 hour period according to OSHA *. 150 Slight headache after 1.5 hours. 200 Slight headache, f atigue, dizziness, nausea after 2-3 hours.
T able B shows ho w the CO Alar m reacts to diff erent lev els of CO gas and exposure time . At higher le vels of CO the alarm tur ns on sooner . The rate of flashing of the red light indicates the le vel of CO .
(Without this f eature the CO lev el would need to be at 50ppm CO f or 90 minutes for an indication to be giv en). Note the Pre-Alar m signal ma y be tr iggered b y CO coming f or example , from cooking with gas, from car engines or from nearby barbecues .
4. WHERE T O PLA CE CO ALARMS 3.1 Ideally a Carbon Mono xide Alar m should be installed in: - Ev er y room containing a fuel burning appliance, and - Remote rooms where occupants spend a considerab le amount of time - Ev er y bedroom.
(2) Outside the building. (3) In an enclosed space (e.g. in or below a cupboard). (4) In a damp or humid area. (5) Directly abov e a sink or cooker . (6) Ne xt to a door , window , air vent or an ywhere that it would be affected b y draughts. (7) Ne xt to an extractor f an.
13 • The CO alarm should be a hor izontal distance of betw een 1m and 3m from the potential CO source. • If there is a par tition in the room, the CO alarm should be located on the same side of the par tition as the potential source. • In rooms with sloped ceilings, the CO alarm should be located at the high side of the room (see fig 3).
3.31 If locating the CO alarm in a bedroom or in r ooms remote from a fuel burning appliance (see figure 4) • Mount the CO alar m relativ ely close to the breathing zone of the occupants . Whate ver position is chosen mak e sure it is possible to view the three light indicators , when in the vicinity of the alar m.
5. INST ALLING Y OUR CARBON MONO XIDE ALARMS The Alar m is designed to be permanently mounted. The unit can be screw ed directly to the wall or ceiling and connected to the mains . It requires a current of 60mA. The Alar m m ust not be exposed to dripping or splashing.
INST ALLA TION PROCEDURE Ei225EN (Only) W arning: The CO alar m should be installed b y a qualified electr ican in accordance with the IEE wiring regulations (BS 7671). F ailure to install this alar m correctly ma y expose the user to shock or fire hazards .
6. The Brown wire (terminal 3) must be connected to the house wiring coloured brown or to a house terminal mar k ed “L ”. The Blue wire (ter minal 4) must be connected to the house wiring coloured blue or to a house terminal mar k ed “N”. The alar m does not need to be earthed, howe ver f or conv enience a spare ter minal (no .
Ei220EN (Only) 1. Slide the cov er off as shown in Figure 7 to e xpose the mounting screw holes . 2. Cut a notch in the back side wall (on the centre of either side or at the bottom, f or the pow er cord) to allow the unit to lie flush against the ceiling/wall.
6. TESTING Y OUR CO ALARM (1) Regularly check that the green mains po wer light is on. The unit cannot detect CO if the mains pow er is not on. (If it is off check circuit break ers, fuses, wiring etc). (2) T est the unit weekly by pressing the test/hush b utton.
inject the CO gas into the gas entr y holes , see Figure 1. When it senses the CO it flashes the red light (as per T able B) to confirm that is detecting CO gas.
Remov e the CO Alar m when decorating. Do not allow water or dust to contaminate the alar m. W arning : Do not open or tamper with the CO Alar m. There are no user ser viceable par ts. This can damage the unit and may e xpose the user to shock or fire hazards .
3. Unscre w the ter minal cov er screw . 4. Disconnect the wires from the terminal block and mak e saf e, par ticularly if the circuit is going to be tur ned on again after the CO Alarm is remov ed. 5. Unscre w from the wall. Ei220EN only 1. Unplug the unit.
(3) The CO Alarm may not be heard. The sound output is loud but it ma y not be heard behind a closed door or if it is too f ar awa y . The Alar m ma y not wak e up somebody who has taken alcohol or drugs. The alarm sound may be mask ed by other sounds such as T .
THE A CUTE EFFECTS OF CARBON MONO XIDE EXPOSURE. IT WILL NO T FULL Y SAFEGU ARD INDIVIDU ALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN DOUBT CONSUL T A MEDICAL PRA CTITIONER. 9. HO W T O PRO TECT Y OUR F AMIL Y F ollow these guidelines to reduce the risk of Carbon Monoxide poisoning.
air comes from and ensure v ents/air br ic ks etc. remain unobstr ucted (par ticularly after building w or k). (4) The appliances must also “breathe out” the waste gases (including the CO) – usually through a flue or chimney . Ensure chimneys and flues are not b locked or leaking, and get them check ed ev er y y ear .
10. TECHNICAL SPECIFICA TION Operating V oltage : 230± 10% V AC , 50Hz P ow er : 1 W att, (60 mA) P ow er on Indicator : Green Light on Sensor : Electrochemical Sensor CO Sensitivity : Meets BS EN 50291: 2001.
Initialisation Time : 70 seconds. On power up red and amber lights flash momentarily to show they are oper ational. Operating T emperature : -10°C to 40°C Humidity Range : 15% to 95% R.
Dimensions : 135 x 105 x 71 mm. W eight : 195g - Ei225EN 290g - Ei220EN 11. GETTING THE CO ALARM SER VICED If your CO Alarm f ails to wor k after y ou hav e carefully read all the instr uctions , checked the unit has been installed correctly , and is receiving AC po wer , - see “How to disconnect and remov e the Alar m” in section 7, page 20.
This guarantee e xcludes incidental and consequential damage. If this Carbon Mono xide Alar m should become def ective within the guarantee period, it must be retur ned to where it w as purchased or alter nativ ely to Ei Electronics., carefully packaged, with the prob lem clearly stated.
13. TROUBLESHOO TING 1. ALARM DOES NO T WORK WITH THE TEST BUTT ON: (1) Check that the g reen mains power light is on. If it is off check the wiring, fuse, circuit breakers etc.
(2) Ensure there are no fumes in the area (e.g. paint, thinners, alcohol, hair spra y , chemical cleaners aerosol spra ys etc). (3) Ensure there is no outdoor source of CO in the vicinity (e.g. a car with engine running, heavy traffic , heavy air pollution, barbecue fumes etc).
PRODUCT DISPOSAL Ei Electronics Shannon, Co . Clare, Ireland. T el: (061) 471277 F ax: (061) 471053 E-mail. helpdesk@eiltd.ie www .eielectronics.com Aico Ltd. Mile End Business P ark, Maesbur y Rd, Os westr y , Shropshire, SY10 8NN, U .K. T el: 0870 7584000 F ax: 0870 7584010 E-mail: suppor t@aico .
An important point after buying a device Ei Electronics Carbon Monoxide Alarm Ei220EN (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ei Electronics Carbon Monoxide Alarm Ei220EN yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ei Electronics Carbon Monoxide Alarm Ei220EN - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ei Electronics Carbon Monoxide Alarm Ei220EN you will learn all the available features of the product, as well as information on its operation. The information that you get Ei Electronics Carbon Monoxide Alarm Ei220EN will certainly help you make a decision on the purchase.
If you already are a holder of Ei Electronics Carbon Monoxide Alarm Ei220EN, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ei Electronics Carbon Monoxide Alarm Ei220EN.
However, one of the most important roles played by the user manual is to help in solving problems with Ei Electronics Carbon Monoxide Alarm Ei220EN. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ei Electronics Carbon Monoxide Alarm Ei220EN along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center