Use the following checklist for items needed: box and open-end wrenches socket set distributor wrench pliers (channel locks & hose clamp) screw drivers (regular and phillips) torque wrench hammer .
3. Drain radiator coolant, move fan shroud back and remove fan and spacer from wa ter pump. On air conditioned vehicles, remove bolt, lower idler pulley and compressor -to- water pump mount. Disconnect hoses and brackets. Most vehic les will require radiator removal prior to cam removal.
• INST ALLING DISTRIBUTOR AND TIMING ENGINE NOTE: Before installing your distributor , check the gear drive on the distributor and oil pump for an y signs of wear . If worn, be sure to replace with new or you may wear out your camshaft prematurely .
TIMING MARKS • WARNING In order for this T orker -Plus cam and lifter kit to be covered under ANY W ARRANTY you MUST use the correct Edelbrock Sure Seat V alve Springs. The end flap or label from your Sure Seat V alve Spring box must be sent in with your camshaft warranty card.
• CAMSHAFT : T orker-Plus Hydraulic • CA T ALOG #5002 • ENGINE: Chevrolet 265-400 c.i.d. V8 • RPM RANGE: 1500-6500 • CAUTION: Do not use dual valve springs. Use only recommended Edelbrock Sure Seat Valve Springs #5703. Use stock ratio rocker arms only .
An important point after buying a device Edelbrock Torker-Plus 265-400 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Edelbrock Torker-Plus 265-400 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Edelbrock Torker-Plus 265-400 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Edelbrock Torker-Plus 265-400 you will learn all the available features of the product, as well as information on its operation. The information that you get Edelbrock Torker-Plus 265-400 will certainly help you make a decision on the purchase.
If you already are a holder of Edelbrock Torker-Plus 265-400, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Edelbrock Torker-Plus 265-400.
However, one of the most important roles played by the user manual is to help in solving problems with Edelbrock Torker-Plus 265-400. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Edelbrock Torker-Plus 265-400 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center