Instruction/ maintenance manual of the product 3565 Edelbrock
Go to page of 16
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 1 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 PERFORMER MUL TI-POINT EFI SYSTEMS for TBI-Equipped Chevrolet/GMC T rucks & Suburbans Catalog.
MANIFOLD ASSEMBL Y CONTENTS Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 2 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 Qty . Description ❑ 1 Manifold assembly (see detail below) ❑ 1 In.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 3 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 IMPOR T ANT INSTRUCTIONS For ordering your FREE Edelbrock computer chip.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 4 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 ® INST ALLA TION INSTRUCTIONS for Performer Multi-Point EFI System for 7.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 5 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 INST ALLA TION PROCEDURE 1. Disconnect negative batter y cable. 2. Drain coolant. 3. Remove air cleaner assembly . 4. Label all lines, wires, and connections with masking tape before disassembly to aid in re-assembly .
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 6 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 10. DISTRIBUTOR REMOV AL Remove plug wires from top of distributor cap.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 7 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 13. INT AKE PREPARA TIONS With fuel lines out of the way , scrape remaining intake gaskets off of cylinder heads and scrape both end seals c lean. With surfaces clean, install intake gaskets to cylinder heads.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 8 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 Tighten the manifold bolts following the tightening sequence shown below. T orque to 25 ft. lbs. Install the distributor in the engine. Using your marks as a reference, snug down distributor clamp.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 9 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 16. HEA TER HOSE SUPPL Y LINE For all years, the heater core supply will come from the right front water port on intake manifold.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 10 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 19. FUEL RETURN LINE INST ALLA TION Install the 90° #6 pushlock fitting into the 10-foot length of hose using the pushlock fitting installation procedures described previously .
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 11 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 Pull rubber grommet off of wires. Force silicone (oxygen sensor - safe) through these four holes, filling them with silicone. Install the grommet on air valve in groove to prevent dirt from entering the system.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 12 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 installed in manifold). Route hose and cut as necessary to prevent interference with linkage. Tighten both clamps and secure with tie wrap as shown.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 13 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 Fuel T ank Disconnect two fuel lines, two hoses, and an electrical connection with a ground wire. There is a center fuel pump sending unit assembly lock ring holding assembly into tank.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 14 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 Note: The fuel line will be a very tight fit over the 3/8" tubing. It may be necessary to lube the tubing with some spray lubricant to ease hose installation.
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 15 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 This installation uses a piggyback chip ada pter . Push your new computer chip into the adapter , then install these two parts into ECM. There is an alignment lug so that they only fit one way .
Catalog #3562, 3563, 3564, 3565 Rev . 3/06 Page 16 of 16 ©2006 Edelbrock Corporation Brochure #63-0047 Edelbrock Corporation • 2700 California St. • T orrance, CA 90503 EFI T ech-Line: (800) 416-8628, Option 3 • E-Mail: EFIT ech@Edelbrock.com ® BASIC TROUBLESHOOTING 1.
An important point after buying a device Edelbrock 3565 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Edelbrock 3565 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Edelbrock 3565 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Edelbrock 3565 you will learn all the available features of the product, as well as information on its operation. The information that you get Edelbrock 3565 will certainly help you make a decision on the purchase.
If you already are a holder of Edelbrock 3565, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Edelbrock 3565.
However, one of the most important roles played by the user manual is to help in solving problems with Edelbrock 3565. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Edelbrock 3565 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center