© 1998 Edelbrock Corp. 12/98 A- Carburetor will work with non-EGR (Exhaust Gas Recirculation) or pre-emission control system. I- Carburetor has no provision for e v aporati v e canister . K- Carburetor requires #8008 or #8024 stud, nut and washer kit.
F igure 3—Remove shaded area to provide clearance for throttle or kick-down bracket F igure 2—262-400 c.i.d. Chevrolet F iring Order— 1-8-4-3-6-5-7-2 T urn Distributor Counter Clockwise to Advance T iming 3. Eliminate the end seals. Use automoti v e grade RTV silicone instead.
© 2001 Edelbrock Corporation Brochure No. 63-0048 Page 1 of 8 Rev 1/02 GENERAL INSTRUCTIONS FOR INT AKE MANIFOLD REMOV AL AND INST ALLA TION The following instructions must be carefully studied and understood befor e you r emove your stock manifold. Failure to follow these instructions may void the warranty .
MANIFOLD AND CARBURETOR HEIGHT : 1. Remove the air cleaner . 2. Lay a straightedge (such as a yardstick) across top of carburetor from front to back. 3. Measure from block and manifold end seal surface. See Figure 3. 4. Record measurements in blank spaces labeled OM1 and OM2.
© 2001 Edelbrock Corporation Brochure No. 63-0048 Page 3 of 8 Rev 1/02 AIR CLEANER: Use stock air cleaners unless changing carburetor . NOTE: If a new or replacement air cleaner is used, there may be inadequate hood clearance. Make sure it performs the same function as stock and meets legal emissions requirements.
© 2001 Edelbrock Corporation Brochure No. 63-0048 Page 4 of 8 Rev 1/02 REMOVING THE STOCK MANIFOLD: 1. Disconnect batter y . 2. For ease of installation, keep all parts in some sort of order . W ARNING : Do not remove manifold if engine is hot. 3. Drain radiator coolant (drain plug will normally be located on lo wer right facing engine).
© 2001 Edelbrock Corporation Brochure No. 63-0048 Page 5 of 8 Rev 1/02 3. Within a few minutes gaskets and surface will become tacky to the touch. Carefully place gaskets on head surface, aligning ports and bolt holes. 4. With Gasket in place apply a small amount of RTV High T emp silicone sealer around water passages intake manifold side.
© 2001 Edelbrock Corporation Brochure No. 63-0048 Page 6 of 8 Rev 1/02 6. Disregard previous mark placed on distributor . 7. Install distributor so that rotor lines up with new mark and points are just open or magnetic trigger wheel aligns with sensor .
© 2001 Edelbrock Corporation Brochure No. 63-0048 Page 7 of 8 Rev 1/02 TROUBLESHOOTING: Below is a list of the most common problems experienced after a manifold installation. Under each problem, we ha ve listed several possible causes for the problem.
© 2001 Edelbrock Corporation Brochure No. 63-0048 Page 8 of 8 Rev 1/02 Edelbrock replacement manifolds are designed to maintain high vacuum at cruise throttle position and sharp throttle response with minimum throttle opening. Unnecessary demands on the added performance will affect mileage.
An important point after buying a device Edelbrock 262-400 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Edelbrock 262-400 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Edelbrock 262-400 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Edelbrock 262-400 you will learn all the available features of the product, as well as information on its operation. The information that you get Edelbrock 262-400 will certainly help you make a decision on the purchase.
If you already are a holder of Edelbrock 262-400, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Edelbrock 262-400.
However, one of the most important roles played by the user manual is to help in solving problems with Edelbrock 262-400. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Edelbrock 262-400 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center