Instruction/ maintenance manual of the product SIT 0.820.634 Drolet
Go to page of 24
ULTRA FLAME DIRECT VENT GAS STOVE INSTRUCTIONS MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
ULTRA FLAME DIRECT VENT GAS STOVE 1 TABLE OF CONTENTS GENERAL INFORMATION .................................................................................................................................................... 2 WARNING ..................
ULTRA FLAME DIRECT VENT GAS STOVE 2 GENERAL INFORMATION The ULTRA FLAME DIRECT VENT GAS STOVE is a high-efficiency gas appliance with a maximum input rating of 30 000 Btu/h (8,8 kW) with natural gas or 26,000 Btu/h (7,6 kW) with propane. It features an adjustable millivolt valve and a constant pilot independent of any electrical source.
ULTRA FLAME DIRECT VENT GAS STOVE 3 TECHNICAL SPÉCIFICATIONS Dimensions TOP VIEW Dimensions Height : 29 in 735 mm Width : 26 in 920 mm Depth : 23 in 585 mm Ceramic Glass F ront : 18 3/16 in x 15 15/1.
ULTRA FLAME DIRECT VENT GAS STOVE 4 Burner Natural Gas Propane LP Maximum Input, BTU/h (kW) minimum : maximum : 20 000 (5,9) 30 000 (8,8) 20 000 (5,9) 26 000 (7,6) Inlet Pressure INWC (kPa) minimum : .
ULTRA FLAME DIRECT VENT GAS STOVE 5 Available Wall Venting Kits Venting Kit for Direct Installation AC05506 Venting Kit for Corner Installation AC05507 DESCRIPTION • Outer pipe ( ∅ 8 in.) for admission of fuel-air in carbon steel, black 24GA ; • Inner flexible pipe ( ∅ 5 in.
ULTRA FLAME DIRECT VENT GAS STOVE 6 SELECTING TYPICAL INSTALLATION Safety Notice • Improper installation may result in a house fire. Fo llow installation directions.
ULTRA FLAME DIRECT VENT GAS STOVE 7 Critical Length of Venting Pipes The following table shows maximum length to be respected while installing your appliance: In conclusion: • If you have no rise (V.
ULTRA FLAME DIRECT VENT GAS STOVE 8 K. 72" Clearance to a mechanical air supply inlet L. 84" Clearance above paved sidewalk or a paved driveway lo cated on public property. A vent shall not terminate directly above a sidew alk or paved driveway w hich is located betw een tw o single family dwellings and serves both dwelling M.
ULTRA FLAME DIRECT VENT GAS STOVE 9 Installation of Wall Venting Kits Direct Vent Kit VENT TERMINAL RADIATION SHIELD -min 1" -max 60" Direct Vent Direct Vent Details 1. Move the stove to its position; 2. Install temporary a 8 in. section (4) to visualize where the opening to be done thru the wall.
ULTRA FLAME DIRECT VENT GAS STOVE 10 13. Seal around the 8 in. pipe to prevent cold air to get into the house. 14. Seal around the cover slots to avoid water infiltration into the vent terminal; 15. Insert spring spacers into the 5 in. flexible pipe; 16.
ULTRA FLAME DIRECT VENT GAS STOVE 11 8. Secure the 8 in. pipe to vent terminal wall plate with the metal screw; 9. Fix finally the vent terminal wall plate with six 2 ½ in screws (12). 10. Insert the 5 in. flexible pipe (3) into the 8 in. pipe and fix it to the vent terminal casing.
ULTRA FLAME DIRECT VENT GAS STOVE 12 Direct Vent Kit for Basement Installation 1. Move the stove to its position; 2. Install temporary an 8 in. section (4) to visualize where the opening to be done thru the wall.
ULTRA FLAME DIRECT VENT GAS STOVE 13 11. Install the vent casing and the cover in place 12. Seal around the terminal to prevent water leakage into the house 13. Seal around the 8 in. pipe to prevent cold air to get into the house. 14. Seal around the cover slots to avoid water infiltration into the vent terminal; 15.
ULTRA FLAME DIRECT VENT GAS STOVE 14 Direct Vent Kit for Floor Installation 1. Move the stove to its position; 2. Install temporarily an 8 in. section (4) to visualize where the opening is to be done thru the wall.
ULTRA FLAME DIRECT VENT GAS STOVE 15 11. Install the vent casing and the cover in place 12. Seal around the terminal to prevent water leakage into the house 13. Seal around the 8 in. pipe to prevent cold air to get into the house. 14. Seal around the cover slots to avoid wa ter infiltration into the vent terminal; 15.
ULTRA FLAME DIRECT VENT GAS STOVE 16 Gas Piping • Move the ULTRA FLAME to the desired position. • Mark the location for the gas inlet pipe and the location where the vent pipes will go through the wall. Remove the appliance. • Route a 3/8" minimum NPT iron pipe gas line to the desired location.
ULTRA FLAME DIRECT VENT GAS STOVE 17 Logs Installation 1. Remove the front glass. 2. Locate the log grate in the retainers in the right and left rear corners. 3. Place the rear log (1) against the rear log stop. Make sure grooves under the log line up with the grate.
ULTRA FLAME DIRECT VENT GAS STOVE 18 OPERATION OF YOUR STOVE For your safety CAUTION: • A qualified installer must perform installation of the appliance, ve nting, piping and adjustments. • During operation, this stove is hot. Do not touch. Keep children, clothing and flammable materials aw ay • Hot when in operation.
ULTRA FLAME DIRECT VENT GAS STOVE 19 Shut down Instructions To turn the burner OFF • Push in and rotate the gas control knob clockwise 3 to "PILOT" position. Do not force. To turn the pilot OFF • Push in and rotate the gas control knob clockwise 3 to "OFF" position.
ULTRA FLAME DIRECT VENT GAS STOVE 20 MAINTENANCE INSTRUCTIONS TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFOR E SERVICING THE APPLIANCE. Yearly maintenance • The venting system and the gas stove should be inspected at least once a year.
ULTRA FLAME DIRECT VENT GAS STOVE 21 Burner Removing the Burner • Remove the glass front assembly. Lift out the gr ate and hearth insert around burner. Unscrew the burner from the bottom of the combustion chamber, • Slide the burner out from the ventury to wards left.
ULTRA FLAME DIRECT VENT GAS STOVE 22 Pilot Assembly OPTIONS DESCRIPTION Part # Millivolt Wall Thermostat AC05558 Blower AC05529 Direct Vent Kit AC05506 Direct Vent Kit Corner Installation AC05507 Dire.
ULTRA FLAME DIRECT VENT GAS STOVE 23 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e-mail : tech@drolet.ca web site : drolet .ca LIMITED WARRANTY The manufacturers warranty extends only to the original consumer purc haser and is not transferable.
An important point after buying a device Drolet SIT 0.820.634 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Drolet SIT 0.820.634 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Drolet SIT 0.820.634 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Drolet SIT 0.820.634 you will learn all the available features of the product, as well as information on its operation. The information that you get Drolet SIT 0.820.634 will certainly help you make a decision on the purchase.
If you already are a holder of Drolet SIT 0.820.634, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Drolet SIT 0.820.634.
However, one of the most important roles played by the user manual is to help in solving problems with Drolet SIT 0.820.634. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Drolet SIT 0.820.634 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center