AES III 825 12 40-02 FOR YOUR SAFETY If you smell gas: 1. Open windows and door . 2. Don’t touch electrical switches. 3. Extinguish any open fl ame. 4. Immediately call your gas supplier . FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
.
3 INTRODUCTION W e are pleased that you have chosen this refrigerator and hope you will deri ve much satisfaction from using it. The refrigerator is designed for installation in motorhomes and intended for storage of foods, frozen foods and making ice.
4 LP GAS OPERA TION AES will select LP gas operation under the follo wing conditions: No A C (230-240V) av ailable Engine not running (no high current at 12V DC av ailable) When the system chooses LP gas operation, the fl ame failure de vice is automatically opened, allo wing the gas to fl ow to the burner .
5 SWITCHING BETWEEN ENERGY SOURCES When switching from one energy source to another , there are some delays implemented in the AES system. The 15 min. delay between switching of f the engine and starting gas mode is intended to delay the starting of gas mode e.
6 CLEANING THE REFRIGERA TOR Clean the inside of the refrigerator regularly to k eep it fresh and hygienic. Soak a cloth in a solution consisting of a teaspoon of bicarbon- ate of soda to half a litre of warm water . Wring out the cloth and use it to clean the interior of the refrigerator and its fi ttings.
7 REMOV AL OF FLUE GASES The ventilation passage at the rear of the recess, between the outer wall of the v ehicle and the refrigerator must be sealed of f against the li ving space, so cold draughts are excluded (winter camping) and no fl ue gases can penetrate into the motorhome .
8 CLEARANCES Minimum clearances (mm) to combustible materials are: RM 2355 (Fig. 5 & Fig. 6) RM 2455 - RM 2555 - RM 4605 (Fig. 5 & Fig. 7) G T op 0 0 K Side 0 0 L Bottom 0 0 M 1 Rear 25 0 1 The distance between the rearmost part of the refrigerator and the wall behind the refrigerator .
9 CONNECTING POINTS Dimensions to connecting points (mm). Electrical connection point Gas connection point Gas pressure test point Flue outlet Gas connection point Electrical connection point RM 2355 .
10 Electrical connection point Gas connection point Electrical connection point Gas connection point pressure test point Flue outlet RM 2555 Electrical connection point Gas connection point Electrical.
11 SECURING THE REFRIGERA TOR For the best cooling performance, when installing the refrigera- tor model(s): RM 2355 - the installer must block the space between the storage cabinet and the top of the refrigerator .
12 Once the lo wer front strip is slipped under the hinge, the part is possible to swing into place as sho wn in Fig. 13. Secure the refrigerator and the lo wer front strip with two scre ws: One scre w through the hinge, and on the opposite side and then, one scre w through the lower front strip, see Fig.
13 CROSS-SECTIONS The D+ (alternator) is a signal cable and therefore 1-1.5 mm 2 is suffi cient. Connection to 12V + and - must be done with a 10 mm 2 wire if the total wire length (+ and - wire together) is maximum 12 m. If longer leads are needed, bigger dimensions are required.
14 With screws (see Fig. 20 and Fig. 22) T o mount the door panel, follow these steps: Open the door 90 degrees. On ne w refrigerators, the decoration strip is taped inside the door; if installed on the door , remo ve the door decoration strip (2) by removing its three scre ws (1).
15 5 1 2 .
16 RM 2355 RM 2455 RM 2555 RM 4605 Overall dimensions Height (mm) 766 948 1104 1385 W idth (mm) 556 632 632 632 Depth incl. cooling unit (mm) 577 627 627 627 Recess dimensions Height (mm) 756 928 1083.
17 REARVIEW EQUIPMENT D+ Power module cover (PC board) Reigniter Rela y Flexible cord Inlet fitting T erminal block 12V DC only D+ 12 or 24V DC Drain water hose Burner jet Screw for protection cover M.
18 WIRING DIAGRAM RM 2355 - RM 2455 - RM 2555 RM 4605.
19 Thermostat S park Gas valve Flame detector device Lock out indication T W TS TS T W I TS T WI TS WORKING INSTRUCTIONS FOR THE GAS SAFETY SYSTEM WORKING DIAGRAM TECHNICAL SPECIFICA TIONS Classifi c.
20 Use the Airing Position Card to keep the doors ajar if the refrigerator will not be in use for an extended period of time or put in storage. 1 2 3 4 APPENDIX A - AIRING POSITION CARD RM 2455 AND RM.
21 APPENDIX A - AIRING POSITION CARD RM 4605 1 2 5 4 3.
NOTES.
.
MO-M 0552.
An important point after buying a device Dometic RM 2455 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dometic RM 2455 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dometic RM 2455 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dometic RM 2455 you will learn all the available features of the product, as well as information on its operation. The information that you get Dometic RM 2455 will certainly help you make a decision on the purchase.
If you already are a holder of Dometic RM 2455, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dometic RM 2455.
However, one of the most important roles played by the user manual is to help in solving problems with Dometic RM 2455. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dometic RM 2455 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center