- 3 - opera ting instructions ____________ 13 refrigera tor over view ..................... 13 instructions for use . . . . . . . . . . . . . . . . . . . . . . 17 storage comp artments .................... 18 product care .............................
- 4 - geNeRal iNfoRMa tioN V entilation is one of the requirements for proper cooling unit operation. The installation should be made in such a manner as to separate the combustion system from the living space of the mobile home or recreational vehicle.
- 5 - cleaRaNces Minimum clearances (in inches) to combustible materials: T op ( G ) 0 Side ( K ) 0 Bottom ( L ) 0 Rear ( M 1 ) 0 / 1 ( ) 1 The distance between the r earmost part of the r efrigerator and the wall behind it.
- 6 - .
- 7 - Be careful when installing the refrigerator models NDM1062 & NDR1292 . These are equipped with the latest v acuum insulated panel technology . The insu- lating panels are located on the top, back, bottom, sides and doors.
- 8 - 3. NDR1292 Install the screws in the following order: 1.
- 9 - Hole for drain water hose Hose Boiler casing coNNectioNs Hook up to the gas supply line is accomplished at the manual .
- 10 - Put back the co ver . 9. Press the ON/OFF button off and then back on. Nor - 10. mal operation of the burner should return. 1 1.
- 1 1 - T o mount the panel, follow these steps: Open the door 90 degrees. 1. On new refrigerators, the decoration strip is taped 2. inside the door; if installed on the door , remove the door decoration strip (2) by removing its three screws (1).
- 12 - T o mount the panel, follow these steps: Open the door 90 degrees. 1. On new refrigerators, the decoration strip are 2.
- 13 - absoRptioN cooliNg systeM .
- 14 - RM2354, RM2454, RM2554 & DM2663 When operating in DC mode (3-way models only), the DC mode indicator lamp is illuminated and all other lamps are off. T o select another operating mode, turn off the DC mode by pressing the DC selector button.
- 15 - refriger a t or oVer View CHECK GAS A UTO ON OFF A UTOMA TIC REFRIGERA TOR TEMPERA TURE CONTROL 1 2 A B button (main power) m.
- 16 - D B ON OFF AC GAS CHECK AES AUT O COLD 1 2 3 4 5 COLDEST CLC LA C A C G E F 1 2 3 4 5 button (main power) mode select.
- 17 - Before starting the refrigerator: Check that all the manual gas valves are in the ON position. Make sure that a continuous 12V DC supply is available for the electronic control to function. T o start the refrigerator: Press the ON/OFF button.
- 18 - MoDel tot al RefRigeRa teD (cu.ft) RM2351 & RM2354 3 RM2451 & RM2454 4 RM2551 & RM2554 5 DM2652, DM2662 & DM2663 6 DM2852, DM2862 & DM3862 8 NDM1062 9.
- 19 - 5 Slide the shelf into the holes on the right- hand side. Put a screwdriver into the slot of the shelf lock. T urn the screwdriver counter clockwise. Remove the shelf locks from the wire shelf. 1 2 Slide the wire shelf to the left. The right-hand side of the shelf will come loose.
- 20 - cleaNiNg usually done after it is defrosted or put into storage.
- 21 - DM2652, DM2662, DM2663, DM2852 & DM2862 1 2 5 4 3 Use the to keep the doors ajar if the refrigerator will not be in use for an extended period of time or put in storage.
- 22 - maintenance & ser Vice T o keep the r efrigerator working properly , a qualified service technician should, at least once a year , inspect the connections, the control system, the LP gas pressur e and flue baffle.
- 23 - peRioDic MaiNteNaNce Check the control system by connecting/disconnecting the .
- 24 - Symptom Check/Remedial action The refrigerator has stopped cooling. Immediately turn the refrigerator off and see a Dometic dealer . Refrigerator or freezer is not cold enough .
- 25 - The following table displays commonly used parts which should be available from your Dometic Service Center . MoDel sp aRe p aRts RM2351 RM2354 RM2451 RM2454 RM2551 RM2554 DM2652 Airing position card N.
- 26 - MoDel sp aRe p aRts DM2662 DM2663 DM2852 DM2862 DM3862 NDM1062 NDR1292 Airing position card 3850781-01 3850781-01 3850781-01 3850781-01 N.A. N.A. N.A. Baffle 2932667-03/9 2932667-03/9 2932667-04/7 2932667-04/7 2932667-04/7 2932667-04/7 2932667-05/4 Bottle holder , 2 pieces N.
- 27 - Please visit the website for information and news about Dometic products. Y ou can obtain information about how to get in contact, .
- 28 - iMpoRt aNt! & .
- 29 - THE SELLER NAMED BELOW MAKES THE FOLLOWING W ARRANTY WITH RESPECT TO THE DOMETIC PRODUCT : .
- 30 - RefRigeRa toR owNeR MaiNteNaNce yeaRl y RecoRD #USTOMER .AME -ODEL .O $ATEOF0URCHASE !DDRES S 3ERIAL .O 3TATE #ITY :IP#ODE 0HONE &)234 9%!2 .
- 31 - RM2351 RM2354 Power module cove r Flexible cord 12 V DC T erminal block Inlet fitting Manual gas shutoff valve Burner jet Screw for protection cover Protection cover Drain water hos e Flue ba f.
- 32 - 12V DC Rela y , 3-Way only Power modul e cover Flexible cord 12 volt DC T erminal block Drain water hose Inlet fitting Manual gas shutoff valve Burner jet Screw for protection cover Protectio n.
- 33 - NDR1292 12V DC Heater s Power modul e cover Flue baffle Pr ote ct io n cove r T hermo f us e Burner jet Manual gas shutoff valve I nle t fitt in g 12 volt Terminal block Flexible cord Drain wat.
- 34 - RM2351, RM2451 & RM2551 RM2354, RM2454 & RM2554 appendix e - wiring dia gr ams.
- 35 - DM2652, DM2852 & DM2862 DM2652, DM2662, DM2852 & DM2862 385 13 9 8 12V DC J A .
- 36 - DM2663 12V DC A B C D E F G CIRCUIT BOARD DISPLA Y FUSE 5 A SWITCH LAM P L K HEATER 12V D C LAM P M N RETAINE R P SWITC H SOLENOID VALV E THERMISTO R CIRCUIT BOARD POWE R T HEATING CABL E PROTE.
- 37 - NDM1062 NDM1062 .
- 38 - NDR1292 NDR1292 .
Dometic Processing Center 2320 Industrial Parkway Elkhart, IN 465.
W ■ ARRANTY VERIFICA TION Y our prompt registration records your right to protection under the terms and conditions of your warranty . OWNER CONFIRMA TION ■ .
An important point after buying a device Dometic DM2862 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dometic DM2862 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dometic DM2862 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dometic DM2862 you will learn all the available features of the product, as well as information on its operation. The information that you get Dometic DM2862 will certainly help you make a decision on the purchase.
If you already are a holder of Dometic DM2862, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dometic DM2862.
However, one of the most important roles played by the user manual is to help in solving problems with Dometic DM2862. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dometic DM2862 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center