Instruction/ maintenance manual of the product BRISK AIR 579 SERIES Dometic
Go to page of 12
1 INST ALLA TION INSTRUCTIONS REVISION: Form No. 3109395.066 8/07 (Replaces 3109395.058) (French 3109660.063) ©2007 Dometic Corporation LaGrange, IN 46761 INST ALLA TION INSTRUCTIONS Lire et comprendre ce manuel avant de procéder à l’installation, à des réglages, de l’entretien ou des réparati ons.
2 INST ALLA TION INSTRUCTIONS SAFETY INSTRUCTIONS This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury .
3 INST ALLA TION INSTRUCTIONS SPECIFICA TIONS 120V AC, 60 HZ., 1PH. 12 AWG Copper up to 24’ * For wire lengths over 24 ft. consult the National Electric Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements.
4 INST ALLA TION INSTRUCTIONS INST ALLA TION INSTRUCTIONS 1. PRECAUTIONS Improper insta llation may damage equipment/could endanger life, cause serious injury and/or property damage. A. Read Installation and Operating Instructions carefully before attempting to start your air conditioner installa- tion.
5 INST ALLA TION INSTRUCTIONS C. AFTER LOCA TION HAS BEEN SELECTED: 1. Check for obstructions in the area where air condi- tioner will be installed. 2. The roof must be designed to support 130 pounds when the RV is in motion. Normally a 200 lb. static load design will meet this requirement.
6 INST ALLA TION INSTRUCTIONS It is the responsibility of the installer of this air condi- tioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. W ater standing around the air conditioner ma y lea k int o the inte ri or caus in g da mage to the pro du ct and the RV .
7 INST ALLA TION INSTRUCTIONS 3. A 3/8” diameter hole will be needed to route the cable through the wall. B. CONTROL CABLE INST ALLA TION A 4-conductor control cable must be routed from the roof opening to the Comfort Control Center ™.
8 INST ALLA TION INSTRUCTIONS 6. DISCHARGE DUCT & CEILING TEMPLA TE INST ALLA TION A. Remove the air box and mounting hardware from their carton. The upper duct is shipped inside the lower duct which is part of the ceiling template. B. Remove the upper duct from the ceiling template and locate it over the blower discharge.
9 INST ALLA TION INSTRUCTIONS TROL KIT A. If your installation included the optional electric heat kit, install it at this time. Follow the instructions with the heat package for its installation procedure. B. T erminate the 4-conductor control cable(s) protruding into the 14-1/4” x 14-1/4” (±1/8”) roof opening.
10 INST ALLA TION INSTRUCTIONS 8. SYSTEM CONFIGURA TION, RESET & CHECKOUT Nowthat thesystem isinstalled, itis necessaryto congurethe elec - tronics and check all operations. Refer to the Operating manual for a description of the air conditioner operation.
1 1 INST ALLA TION INSTRUCTIONS FIG. 16 T wo Zone Conguration FIG. 15 9. AIR BOX INST ALLA TION A. Remove return air grille from air box by pulling in on half- roundngercatches. B. Hold air box up to ceiling template and install three (3) #10 x 3/8” (C) screws at air box mounting point.
12 INST ALLA TION INSTRUCTIONS AIR CONDITIONING UNIT A. (4) 1/4” — #20 x 7” bolts B. (4) #8 x 5/8” long sharp point wood screws C. (7) #10 x 3/8” blunt point tapping screws D.
An important point after buying a device Dometic BRISK AIR 579 SERIES (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dometic BRISK AIR 579 SERIES yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dometic BRISK AIR 579 SERIES - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dometic BRISK AIR 579 SERIES you will learn all the available features of the product, as well as information on its operation. The information that you get Dometic BRISK AIR 579 SERIES will certainly help you make a decision on the purchase.
If you already are a holder of Dometic BRISK AIR 579 SERIES, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dometic BRISK AIR 579 SERIES.
However, one of the most important roles played by the user manual is to help in solving problems with Dometic BRISK AIR 579 SERIES. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dometic BRISK AIR 579 SERIES along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center