Instruction/ maintenance manual of the product VYGF33NRC Desa
Go to page of 40
For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- .
www .desatech.com 1 13109-01C 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Product Identication ........................................... 4 Local Codes..............................
www .desatech.com 1 13109-01C 3 - .
www .desatech.com 1 13109-01C 4 O F F P I L O T O N H I L O SAFETY INFORMA TION Continued 1. This ap pli anc e i s on ly for us e w ith the ty pe of ga s ind ica ted on the rati ng plat e. This appl ia nc e is n ot con ver tibl e f or use wit h o the r g ases .
www .desatech.com 1 13109-01C 5 LOCAL CODES Install and use replace with care. Follow all local codes. In the absence of local codes, use the lat - est edition of The National Fuel Gas Code, ANSI Z223.1/NFP A 54 *. *A vailable from: American National Standards Institute, Inc.
www .desatech.com 1 13109-01C 6 While it is good to make your home energy ef - cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation. Exhaust fans, replaces, clothes dryers and fuel burni ng app liance s draw air f rom t he hou se to operate.
www .desatech.com 1 13109-01C 7 Example: Gas water heater ______________ Btu/Hr V ent-free replace + _____________ Btu/Hr T otal = _____________ Btu/Hr 4.
www .desatech.com 1 13109-01C 8 INST ALLA TION NOTICE: This heater is intended .
www .desatech.com 1 13109-01C 9 ASSEMBLING AND A TT ACHING OPTIONAL PERIMETER TRIM IMPOR T ANT : If you are recessing the rebox in a wall, do not attach perimeter trim at this time.
www .desatech.com 1 13109-01C 10 INST ALLA TION Continued CONVENTIONAL FIREPLACE INST ALLA TION Conven tiona l instal latio n of this replac e involv es installing replace along with the corner , face or cab ine t mantel with hearth base acces sor ies aga ins t a wall in your home.
www .desatech.com 1 13109-01C 1 1 INST ALLA TION Continued 10. If bl owe r is in sta ll e d, ro ut e bl o we r el ect ri c a l c o rd th ro ugh ac c es s h ole s i n ei th er sid e o f r ep lac e. No te: Bus hin g may be mo ved if nec ess ary . Pl u g el ec tri ca l cor d in to el ec tri ca l out le t.
www .desatech.com 1 13109-01C 12 INST ALLA TION Continued .
www .desatech.com 1 13109-01C 13 INST ALLA TION Continued Mantel Clearances for Built-In Installation If placi ng mant el above built- in rep lac e, you must mee t mini mum clear anc e betw ee n mant el shel f and top of replace opening.
www .desatech.com 1 13109-01C 14 .
www .desatech.com 1 13109-01C 15 2. Remove screws that attach log base assembly to replace (see Figure 23). Carefully lift up log base assembly and remove from replace (see Figure 23). Note: If adding the G8005 series brick liner acces - sory , install it now .
www .desatech.com 1 13109-01C 16 INST ALLA TION Continued 2. Cap off open end of gas pipe where equipme nt shutoff valve was connected. 3. Pr ess ur ize su pp ly p ipi ng sy st em by e ith er opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air .
www .desatech.com 1 13109-01C 17 O F F P I L O T O N H I L O INST ALLING LOGS CA UTI ON: Do n ot remove th e .
www .desatech.com 1 13109-01C 18 OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES 1. Disconnect switch wires from the control valve.
www .desatech.com 1 13109-01C 19 INST ALLA TION Continued INST ALLING 9-VOL T BA TTERIES T wo 9-volt batteries (not included) are required to operate this heater with the wireless hand held remote control set. Install one battery in the receiver and one in the hand-held remote control unit.
www .desatech.com 1 13109-01C 20 LIGHTING INSTRUCTIONS .
www .desatech.com 1 13109-01C 21 OPERA TING FIREPLACE Continued W ARNING: Make sure the selector switch is in the OFF .
www .desatech.com 1 13109-01C 22 OPERA TING FIREPLACE Continued The hand-held remote can be operated using either the manual mode (MANU) or thermo - static mode (AUTO) (see Figure 43).
www .desatech.com 1 13109-01C 23 INSPECTING B URNER Check pilot ame pattern and burner ame pat - terns often. PILOT FLAME P A TTERN Figure 44 shows a correct pilot ame pattern. Figure 45 shows an incorrect pilot ame pattern. The incorrect pilot ame is not properly heating the thermocouple.
www .desatech.com 1 13109-01C 24 CLEANING AND MAINTENANCE .
www .desatech.com 1 13109-01C 25 TROUBLESHOO TING .
www .desatech.com 1 13109-01C 26 TROUBLESHOO TING Continued POSSIBLE CAUSE 1. Co nt r o l k no b no t f ul ly p re s s e d in 2. Control knob not pressed in long enough 3. Equipment shutoff valve not fully open 4. Pilot ame not touching ther - mocouple, which allows ther - mocouple to cool, causing pilot flame to go out.
www .desatech.com 1 13109-01C 27 POSSIBLE CAUSE 1. Not enough combustion/ven - tilation air 1. T urning con tro l knob to HI po - siti on whe n b urne rs are co ld 2. Air in gas line 3. Air passageways on heater blocked 4 . Dirty or partially clogged burner orice(s) 1 .
www .desatech.com 1 13109-01C 28 .
www .desatech.com 1 13109-01C 29 WIRING DIAGRAM Not e: For prop er oper ati on of option al acc ess ori es, the wires from the switch to the control must be connected exactly as shown.
www .desatech.com 1 13109-01C 30 17 27 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1a 1c 1b 5 9 28 14 13 25 15 16 21 1 1 10 19 20 19 23 22 18 24 29 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 13109-01C 31 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
www .desatech.com 1 13109-01C 32 ILL USTRA TED P ARTS BREAKDOWN 17 27 4 O F F P I L O T O N H I L O 8 12 26.
www .desatech.com 1 13109-01C 33 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
www .desatech.com 1 13109-01C 34 ILL USTRA TED P ARTS BREAKDOWN 4 1 1 14 8 14 9 3 14.
www .desatech.com 1 13109-01C 35 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
www .desatech.com 1 13109-01C 36 ILL USTRA TED P ARTS BREAKDOWN 4 1 1 14 18 19 20 1.
www .desatech.com 1 13109-01C 37 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
www .desatech.com 1 13109-01C 38 ACCESSORIES NOTICE: All accessories may Purchase these replace accessories from your lo - cal dealer .
www .desatech.com 1 13109-01C 39 CORNER CABINET MANTEL WITH BASE AND PERIMETER TRIM 32" Unnished, T raditional Design .
Model Serial No. Date Purchased 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com LIMITED WARRANTY VENT -FREE GAS FIREPLACE DESA Heating Products warrants this produ.
An important point after buying a device Desa VYGF33NRC (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa VYGF33NRC yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa VYGF33NRC - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa VYGF33NRC you will learn all the available features of the product, as well as information on its operation. The information that you get Desa VYGF33NRC will certainly help you make a decision on the purchase.
If you already are a holder of Desa VYGF33NRC, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa VYGF33NRC.
However, one of the most important roles played by the user manual is to help in solving problems with Desa VYGF33NRC. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa VYGF33NRC along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center