Instruction/ maintenance manual of the product VP11 Desa
Go to page of 24
Save this manual for future reference. VENT -FREE PROP ANE GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL ® G I D E S I N N A E S T D C E R T I I F I E A M C R A S O C I A O N ® GS A Models: VP5A and VP1 1 W ARNING : Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage.
2 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ..........................
3 SAFETY INFORMA TION Continued ! WARNING ICON G 001 W ARNINGS Continued 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 3.
4 PRODUCT IDENTIFICA TION PRODUCT FEA TURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
5 INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow all local codes. Continued CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
6 2. Mark two mounting screw locations on wall (see Figure 3). INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater.
7 Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit.
8 Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 7). 2. Place large openings of slots over screwheads.
9 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water.
10 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Figure 11 - Gas Connection * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection.
11 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once.
12 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. Control Knob A.
13 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 12. If you don’t smell gas, go to the next step. 5. Press in control knob.
14 TO SELECT HEATING LEVEL Figure 16 - Burner Patterns 1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW or HIGH positions (VP11) or ON position (VP5A). IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.
15 Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Remove front panel (see Figure 8, page 8).
16 BURNER FLAME PATTERN Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern. Figure 19 - Correct Burner Flame Pattern (Model VP11 Shown) Figure 20 - Incor.
17 TROUBLE- SHOOTING POSSIBLE CAUSE 1 . Ignitor electrode posi- tioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not con- nected to ignitor cable 4. Ignitor cable pinched or wet 5. Broken ignitor cable 6. Bad piezo ignitor 1. Gas supply turned off or manual shutoff valve closed 2.
18 REMEDY 1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 10 seconds 3. Fully open manual shut- off valve 4. Hand tighten until snug, then tighten 1/4 turn more 5. A) Contact local pro- pane gas company B) Clean ODS/pilot (see CLEANING AND MAINTENANCE, page 16) or replace ODS/pilot assembly 6.
19 POSSIBLE CAUSE 1. Plaque damaged 2. Inlet gas pressure is too low 3. Control knob set be- tween locked positions 1. Residues from manu- facturing processes 1. Metal expanding while heating or contracting while cooling 1. Heater burning vapors from paint, hair spray, glues, etc.
20 If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
21 When gas pressure is too low • pilot will not stay lit • burner(s) will have delayed ignition • heater will not produce specified heat • propane gas supply may be low When gas quality is ba.
22 P ARTS LIST Model VP5A KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-01 Front Panel Assembly 1 3 099318-01 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 099469.
23 KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-01 Front Panel Assembly 1 3 099318-01 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 099469-02 Reflector Assembly .
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
An important point after buying a device Desa VP11 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa VP11 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa VP11 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa VP11 you will learn all the available features of the product, as well as information on its operation. The information that you get Desa VP11 will certainly help you make a decision on the purchase.
If you already are a holder of Desa VP11, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa VP11.
However, one of the most important roles played by the user manual is to help in solving problems with Desa VP11. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa VP11 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center