Instruction/ maintenance manual of the product S42RH Desa
Go to page of 20
Sav e this manual for future reference. For more information, visit www .desatech.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed.
www .desatech.com 1 1 1099-01C 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury , property damage or loss of life. Refer to this manual for assis - tance or additional information. Consult a qualified installer or local distributor .
www .desatech.com 1 1 1099-01C 3 SPECIFICA TIONS 0" TO BOTTOM (LEFT SIDE ONL Y) OUTSIDE AIR TOP SP ACERS BACK AND SIDES 3/4" AIR SP ACE HEARTH EXTENSION 66" X 20" TO PERPENDICULAR .
www .desatech.com 1 1 1099-01C 4 FI RE PL AC E IN ST AL LA T IO N SELECTING LOCA TION T o determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Figures 1 and 2).
www .desatech.com 1 1 1099-01C 5 Note: For outdoor installations, the fireplace en- clos ure must allow for adequa te drainag e and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the fireplace within the fireplace enclosure.
www .desatech.com 1 1 1099-01C 6 Figure 6 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 42" Fireplace 44 " 12-8DM 12-8HT Pipe Section 10 5 / 8 " 18-8DM 18-8HT Pipe Section 16 5 /.
www .desatech.com 1 1 1099-01C 7 VENTING INST ALLA TION Continued Con ti nue to ass emb le chi mne y sect ion s as outl ine d, maki ng sure that both the inner and outer pipe sec - tion s are lock ed toge ther .
www .desatech.com 1 1 1099-01C 8 VENTING INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (FS-8DM) Fi re st op sp ac er s are req uir ed at eac h po in t whe re th e chim ney p en etra tes a fl oor s pa ce .
www .desatech.com 1 1 1099-01C 9 VENTING INST ALLA TION Continued 14 3 / 8 " Min. (365 mm) 30" Min. (762 mm) 1" Min. (25 mm) 1" Min. (25 mm) 1" Min. (25 mm) Opening "A" Pitch Slope Opening "A" Max. Used Flashing Model No.
www .desatech.com 1 1 1099-01C 10 T erminations with 16" slip pipe sections are avail- abl e. The R TT -8DM and R TTL-8 DM are appro ved for flashing installations. When needed, these adjustable terminations may be used in combina- tion with the pipe assembly to achieve the correct chimney height.
www .desatech.com 1 1 1099-01C 1 1 OPTIONAL GAS LINE INST ALLA TION Gas line hook up should be done by your supplier or a qualified service person. Note : Before you proceed, make sure your gas supply is turned off. Use only a 1/2" blac k iron pip e and appr opri ate fitti ngs .
www .desatech.com 1 1 1099-01C 12 OPTIONAL GAS LINE INST ALLA TION Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is c om pl e te d. Aft er e ns ur i ng that the gas valve is on, apply soap and water solution to all conn ecti ons and joints .
www .desatech.com 1 1 1099-01C 13 Figure 22 - Damper and Air Kit Handle A fireplace equipped with glass doors operates mush differently than a fireplace with an open front.
www .desatech.com 1 1 1099-01C 14 ILL USTRA TED P ARTS BREAKDOWN WOODBURNING FIREPLACE MODELS S42, S42H, S42R, S42RH, VS42(1) AND VS42H(1) 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 1.
www .desatech.com 1 1 1099-01C 15 KEY NO. P ART NO. DESCRIPTION QTY . 1 107797-01 Insulation Pan 1 2 107798-01 Fireplace T op 1 3 107800-01 Fireplace Surround 1 4 106642-01 Air Rod Retainer 1 5 106643.
www .desatech.com 1 1 1099-01C 16 REPLACEMENT P ARTS 24-8DM 48-8DM 36-8DM 18-8DM 12-8DM EP-42 DOUBLE WALL PIPE EMBER PROTECTOR ST ANDARD BRICK LINER HERRINGBONE BRICK LINER GRA TE PN 1 1 1 100-01 36-8.
www .desatech.com 1 1 1099-01C 17 _____________________________________________________ ______________________________________________________ ______________________________________________________ __.
www .desatech.com 1 1 1099-01C 18 _____________________________________________________ ______________________________________________________ ______________________________________________________ __.
www .desatech.com 1 1 1099-01C 19 _____________________________________________________ ______________________________________________________ ______________________________________________________ __.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 1 1099-01 Rev . C 09/05 111099 01.
An important point after buying a device Desa S42RH (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa S42RH yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa S42RH - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa S42RH you will learn all the available features of the product, as well as information on its operation. The information that you get Desa S42RH will certainly help you make a decision on the purchase.
If you already are a holder of Desa S42RH, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa S42RH.
However, one of the most important roles played by the user manual is to help in solving problems with Desa S42RH. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa S42RH along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center