Go to page of 24
OWNER’S OPERA TION AND INST ALLA TION MANUAL BLUE-FLAME VENT -FREE PROP ANE/LP GAS HEA TER Save this manual for future reference. RP30E CGP20B CGP20LB WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME Carbon Monoxide Poisoning : Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced.
3 104412 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Vent-Free Propane/LP Gas Heater PRODUCT FEA TURES SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free heaters.
4 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever.
5 104412 OWNER’S MANUAL Continued WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.
6 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12&.
7 104412 OWNER’S MANUAL CAUTION: If you install the heater in a home garage • heater pilot and burner must be at least 18 inches above floor • locate heater where moving vehicle will not hit it .
8 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME INSTALLING HEATER TO WALL Figure 5 - Mounting Bracket Location Removing Front Panel Of Heater 1. Remove two screws near bottom cor- ners of front panel. 2. Lift straight up on grill guard until it stops.
9 104412 OWNER’S MANUAL Continued Figure 10 - Mounting Heater Onto Mounting Bracket Figure 11 - Installing Bottom Mounting Screws INST ALLA TION Continued Figure 8 - Folding Anchor Figure 9 - Poppin.
10 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME Figure 13 - Gas Connection * A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer.
11 104412 OWNER’S MANUAL ON POSITION OFF POSITION INST ALLA TION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak.
12 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. T ur n control knob clockwise to the PILO T position. 2. Press in control knob and tur n c lock- wise to the OFF position. 3. T urn off all electric power to the ap- pliance if service is to be perf ormed.
13 104412 OWNER’S MANUAL INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.
14 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME TROUBLESHOOTING WARNING: Turn off and unplug heater and let cool be- fore servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
15 104412 OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during i.
16 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME TROUBLESHOOTING Continued WARNING ICON G 001 WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
17 104412 OWNER’S MANUAL REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
18 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME 1 2 4 5 6 6 7 8 8 9 10 11 12 15 17 19 21 22 23 20 26 25 18 14 16 24 3 13 ODS/PILOT 10-1 10-2 ILLUSTRA TED PA R T S BREAKDOWN RP30E.
19 104412 OWNER’S MANUAL P AR TS LIST RP30E This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual.
20 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME ODS/PILOT 12-1 12-2 1 2 3 4 5 6 8 8 9 10 10 11 12 13 14 17 19 25 21 23 24 7 22 27 26 20 16 18 15 ILLUSTRA TED PA R T S BREAKDOWN CGP20B CGP20LB.
21 104412 OWNER’S MANUAL P AR TS LIST CGP20B CGP20LB This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY.
22 104412 VENT -FREE PROP ANE/LP GAS HEA TER BLUE-FLAME ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central or call DESA International’s Parts Department at 1-800-972-7879 for referral information.
23 104412 OWNER’S MANUAL P AR TS CENTRALS These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. When calling a Parts Central, ask for the Parts Department.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
An important point after buying a device Desa RP30E (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa RP30E yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa RP30E - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa RP30E you will learn all the available features of the product, as well as information on its operation. The information that you get Desa RP30E will certainly help you make a decision on the purchase.
If you already are a holder of Desa RP30E, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa RP30E.
However, one of the most important roles played by the user manual is to help in solving problems with Desa RP30E. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa RP30E along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center