Instruction/ maintenance manual of the product CD36M Desa
Go to page of 22
CD32M (-1)(-2), CD36M (-A1)(-A2), CD42M-A FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 2 Models CD32M sereies, CD36M-A series and CD42M-A are heat circulating gravity direct-vent fireplaces with sealed combustion chamber. These fireplaces use millivolt gas control valve and millivolt ignition system.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 SELECTING LOCA TION To determine the safest and most efficient location for your fire- place, consider the following guidelines: 1. The location must allow for proper clearances (see Figure 1).
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 4 PRE-INST ALLA TION PREP ARA TION Continued VENT TERMINATION CLEARANCES The final position of your fireplace depends on the location of the vent termination in relation to the clearances that must be observed as shown in Figure 5 on page 5.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 6 VENTING INSTALLATION 1. Install elbow to fireplace collar adapter located on back of the unit at a 45° angle. Slide elbow over collar and twist to lock.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 Figure 8 - Vertical Termination with Offset and Wall Strap Wall Strap Roof Flashing 45 ° Elbows Ceiling Firestop Roof Pitch Minimum Height Above Roof Flat - 7/12 1 ft.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 8 INST ALLA TION Continued GAS LINE HOOK-UP WARNING: Gas line hook-up should be done by your gas supplier or a qualified service person. WARNING: Before you proceed, make sure your gas supply is OFF.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 INST ALLA TION Continued REMOVING GLASS PANEL CAUTION: Before you proceed, make sure your gas control valve is in the OFF position.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 10 INST ALLA TION Continued Figure 23 - Installing Log #1, Model CD42M-A Figure 24 - Installing Log.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 INST ALLA TION Continued Lava Rock and Ember Material 1. For all models, place lava rock along sides and front of firebox bottom in areas that are visible.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 12 OPERATION GUIDELINES • When used for the first time, the fireplace may emit a slight odor for about 16 to 24 hours.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 Figure 32 - Control Knob in Pilot Position Figure 33 - Pilot Thermocouple Pilot Burner Piezo .
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 14 WARNING: The conversion kit must be installed by a qualified service technician in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having juris- diction.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 TROUBLESHOOTING OBSERVED PROBLEM Pilot will not stay lit Pilot lit but no flame on burner Frequent pilot outage POSSIBLE CAUSE 1. Defective thermocouple 1.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 16 6 7 19 18 10 12 23 24 34 2 11 17 8 21-2 21-6 21-4 21-5 21-3 21-1 1 13 9 16 3 14 4 20 15 5 15 42 .
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 KEY PART NUMBER NO. CD32M CD36M-A DESCRIPTION QTY.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 18 ILLUSTRA TED PARTS BREAKDOWN MODEL CD42M-A 37 23 41 42 38 22 39 32 31 33 28 26 25 29 24 34 35 40.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 KEY PART NO. NUMBER DESCRIPTION QTY. 1 ** Firebox Assembly 1 2 ** Face Weldment 1 3 108328-01.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 20 SPECIFICA TIONS CD32M CD36M-A CD42M-A Gas Rate (Natural) 16,000/23,000 Btu/hr 15,000/22,000 Btu/.
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 ACCESSOR Y AND REPLACEMENT P ARTS P/N 104506-20 P/N 104506-20 P/N 110994-01 (CD36M-A SERIES) .
111916-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 22 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.
An important point after buying a device Desa CD36M (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa CD36M yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa CD36M - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa CD36M you will learn all the available features of the product, as well as information on its operation. The information that you get Desa CD36M will certainly help you make a decision on the purchase.
If you already are a holder of Desa CD36M, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa CD36M.
However, one of the most important roles played by the user manual is to help in solving problems with Desa CD36M. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa CD36M along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center