Instruction/ maintenance manual of the product (V)T32EN SERIES Desa
Go to page of 40
For more information, visit www .desatech.com DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL NA TURAL GAS “TUDOR” MODEL (V)T32EN SERIES PROP ANE/LP GAS “TUDOR” MODEL (V.
www .desatech.com 1 1 1987-01D 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Local Codes......................................................... 4 Product Identication ...............
www .desatech.com 1 1 1987-01D 3 SAFETY INFORMA TION Continued This replace must be installed by a qualied (cer - tied or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system.
www .desatech.com 1 1 1987-01D 4 SAFETY INFORMA TION Continued 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrica l switch; do not use any phone in your building • immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 1 1 1987-01D 5 Figure 2 - Common Fireplace Locations Flush with a wall Through exterior wall enclosed in a chase Corner installation • The blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the replace when framing.
www .desatech.com 1 1 1987-01D 6 PRE-INST ALLA TION PREP ARA TION Continued Figure 4 - Framing Clearances for Installation Against an Exterior Wall Figure 5 - Framing Clearances for Corner Installation C B A D E F G T op of Louver Opening 3 2 1 4 5 6 7 Wall Ref.
www .desatech.com 1 1 1987-01D 7 Figure 7 - Minimum Clearances for T ermination Cap LOCA TION OF TERMINA TION CAP Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N .
www .desatech.com 1 1 1987-01D 8 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- .
www .desatech.com 1 1 1987-01D 9 INST ALLA TION PLANNING There are two basic types of direct-vent in - stallation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORTANT : Horizontal square terminations require only inner portion of wall restop.
www .desatech.com 1 1 1987-01D 10 VENTING INST ALLA TION INSTRUCTIONS Continued W ARNING: Do not recess 6.
www .desatech.com 1 1 1987-01D 1 1 VENTING INST ALLA TION INSTRUCTIONS Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Scr.
www .desatech.com 1 1 1987-01D 12 CORN ER AND AL TERNA TE INST ALL A TIO N Recommended Applications: • Corner ground oor installation • G ro un d o or in st a l la ti on w he re pi p e v en.
www .desatech.com 1 1 1987-01D 13 VENTING INST ALLA TION INSTRUCTIONS Continued Horizontal (H 1 Horizontal (H 1 Horizontal (H 2 5' min.
www .desatech.com 1 1 1987-01D 14 INST ALLA TION FOR VERTICAL TERMINA TION Note: V ertical restrictor must be installed in all vertical installations. 1.
www .desatech.com 1 1 1987-01D 15 Figure 20 - Installing Firestop If area above is a living space, install restop below framed hole. If area above is an attic or insulated area, install restop above framed hole. 7. T wist-lock the vent cap onto the last section of vent pipe.
www .desatech.com 1 1 1987-01D 16 VENTING INST ALLA TION INSTRUCTIONS Continued Note : Install restrictor into inner collar of replace as shown. V ertical (V 1 5' min.
www .desatech.com 1 1 1987-01D 17 AND COMPONENTS P47-6 6".
www .desatech.com 1 1 1987-01D 18 FIREPLACE INST ALLA TION Use proper gas type for replace unit you are installing.
www .desatech.com 1 1 1987-01D 19 FIREPLACE INST ALLA TION Continued Figure 28 - Location of Wiring Diagram Decal (Model May V ary from Illustration) Wiring Diagram Decal 12" in Front of Burner 9. Check to make sure power cord is completely clear of blower wheel and there are no other foreign objects in blower wheel.
www .desatech.com 1 1 1987-01D 20 1 1. Peel off backing paper and stick supplied wiring diagram decal on rebox bottom ap - proxima tely 12" in front of blower (see Figure 28, page 19).
www .desatech.com 1 1 1987-01D 21 FIREPLACE INST ALLA TION Continued Figure 32 - Gas Connection CSA Design-Certied Equipment Shutoff V alve with 1/8" NPT T ap* 3" Minimum Approved Flexible Gas Line Cap Pipe Nipple T ee Joint Sediment T rap/Drip Leg Natural - From Gas Meter (5.
www .desatech.com 1 1 1987-01D 22 PRESSURE TESTING GAS SUPPL Y PIPING SYSTEM T est Pressures In Excess Of 1/2 PSIG 1. Dis conne ct rep lac e and i ts indiv idual equ ip - ment shutoff valve from gas supply piping sy st em .
www .desatech.com 1 1 1987-01D 23 REMOVING/REPLACING GLASS DOOR .
www .desatech.com 1 1 1987-01D 24 .
www .desatech.com 1 1 1987-01D 25 4. Place log #4 (right log) onto pin on right side of front log as shown in Figure 44. 5. Pl ace lo g #5 (base log) onto front left part of grate making sure notches t over prongs of grate. See Figure 45. 6. Place log #6 (left log) onto two pins on left side of back and front log.
www .desatech.com 1 1 1987-01D 26 FIREPLACE INST ALLA TION Continued Ember Material Figure 46 - Placing Ember Material on Burner 8. Pull ember material apart into pieces no larg er than a dime.
www .desatech.com 1 1 1987-01D 27 STEP DOWN TRANSFORMER PV GND PV/MV TR MV TH IGN EV2 INCOMING MAIN GAS SUPPL Y EV1 GAS LINE TO BURNER 24V AC 120V AC INCOMING 120V AC (FUSE BOX OR BREAKER) OFF ON WALL SWITCH (NOT SUPPLIED) GREEN BLACK WHITE 120v , 60Hz, 0.
www .desatech.com 1 1 1987-01D 28 5. T u rn eq ui pme nt shu to ff val ve clo ck wis e to the OFF position (see Figure 49). Do not force. 6. W ait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor .
www .desatech.com 1 1 1987-01D 29 OPERA TING FIREPLACE Continued TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be performed. 3. Open lower louver panel. 4. T u rn eq ui pme nt shu to ff val ve clo ck wis e to OFF .
www .desatech.com 1 1 1987-01D 30 CLEANING AND MAINTENANCE .
www .desatech.com 1 1 1987-01D 31 TROUBLESHOO TING .
www .desatech.com 1 1 1987-01D 32 Pilot will not stay lit No gas to burner, although wall switch and valve are set to the ON position Frequent pilot ou.
www .desatech.com 1 1 1987-01D 33 Glass soots Remote does not function Dark residue on logs or inside of replace 1. Flame impingement on logs 2 . Debris around burner air mixer 1.
www .desatech.com 1 1 1987-01D 34 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1987-01D 35 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
www .desatech.com 1 1 1987-01D 36 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1987-01D 37 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
www .desatech.com 1 1 1987-01D 38 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty .
www .desatech.com 1 1 1987-01D 39 ACCESSORIES NOTICE: All accessories may Pu rch ase th ese rep lace acce ss or ies from your loca l reta iler .
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 1 1987-01 Rev . D 03/06 WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
An important point after buying a device Desa (V)T32EN SERIES (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Desa (V)T32EN SERIES yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Desa (V)T32EN SERIES - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Desa (V)T32EN SERIES you will learn all the available features of the product, as well as information on its operation. The information that you get Desa (V)T32EN SERIES will certainly help you make a decision on the purchase.
If you already are a holder of Desa (V)T32EN SERIES, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Desa (V)T32EN SERIES.
However, one of the most important roles played by the user manual is to help in solving problems with Desa (V)T32EN SERIES. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Desa (V)T32EN SERIES along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center