Instruction/ maintenance manual of the product 3Ax-602646-xUxx Delta Tau
Go to page of 40
^1 HARDWARE REFERENCE MANUAL ^2 Quad Amp ^3 4-Axis Digital Amplifier ^4 3Ax-602646-xUxx ^5 September 24, 2003 Single Source Machine Control Power // Flexibility // Ease of Use 21314 Lassen Street Chatsworth, CA 91311 // Tel. (818) 998-2095 Fax. (818) 998-7807 // www.
Copyright Information © 2003 Delta Tau Data Systems, Inc. All rights reserved. This document is furnished for the customers of Delta Tau Data Systems, Inc. Other uses are unauthorized without written permission of Delta Tau Data Systems, Inc. Information contained in this manual may be updated from time-to-time due to prod uct improvements, etc.
Quad Amp Hardware Reference Manua l Table of Contents i Table of Contents INTRODUCTION ................................................................................................................... .................................... 1 Related Technical Doc umentation .
Quad Amp Hardware Reference Manua l Table of Contents i i Jumpers, Potentiometers, Te st Points, and LEDs ................................................................................. .............. 21 Grounding ...................................
Quad Amp Hardware Reference Manua l Introduction 1 INTRODUCTION The Delta Tau Data Systems, Inc. 4-axis Digital Amplifier (Quad Amp) is a highly compact digital amplifier and power supply, packaged together to provide four axes of bi-directional (four quadrant) torque control for a variety of AC or DC brushl ess or AC induction motors.
Quad Amp Hardware Reference Manua l Introduction 2 Quad Amp Basic Specifications Physical Specifications Size ( See Figure 1 ) • Height: 22.0 Inches • Width: 10.5 Inches • Length: 5.125 Inches (without mounting optio n) 9.031 Inches (with mounting option) Weight • 60 lb.
Quad Amp Hardware Reference Manua l Introduction 3 Main DC bus Voltage 170 VDC ( 120 VAC line i nput) (L1, L2) 300 VDC ( 208 VAC line i nput) (L1, L2, L3) 325 VDC ( 230 VAC line i nput) (L1, L2, L3) For dem o only Internal Shunt Resistor Resistance 15 Ohm Resistor power 1.
Quad Amp Hardware Reference Manua l Introduction 4 USE 1/ 4- I NCH MOUNTIN G HARDWARE ( 4 PL AC ES ) AIR FL OW Figure 1 Quad Amp Specifications Output Specifications for 120/208/230 VAC Amplifier Up to four blocks (options) can be selected in an y power combination.
Quad Amp Hardware Reference Manua l Introduction 5 Opt 5 Opt 6 Opt 7 Opt 8 Opt 9 Opt 10 Opt 11 Opt 12 Opt 13 Opt 14 Continuous HP(100%) 0.75 HP 0.56 kW 1.5 HP 1.1 kW 2 HP 1.5 kW 3 HP 2.2 kW 5 HP 3.7 kW 7.5 HP 5.6 kW 10 HP 7.5 kW 15 HP 11 kW 20 HP 15 kW 30 Hp 22.
Quad Amp Hardware Reference Manua l Introduction 6 Protection There are several layers of protection built into the am plifier, including transient voltage filters, transient surge suppressors, fuses, a flyback diode, and a variety of fault detection circuits.
Quad Amp Hardware Reference Manua l Introduction 7 Configurable Options Each Quad Amplifier is shipped with an Identifi cation Tag (see Figure 1). The identification tag is attached to the top panel of the Quad Amplifier. It indicates the rating of each axis, the AC operating voltage, and the control input voltage.
Quad Amp Hardware Reference Manua l Introduction 8 Accessories Item Description Note 3A1-602582-100 Circuit Break er 50 Amps 450 V AC 3 Phase With extern al trip 3A2-602582-100 Circuit Break er 70 Amps 250 V AC 3 Phase N A 200-602739-02 4 PWM I nput Cables 36” long cable with DB36 pin mini connectors at each end Two require d per Acc-8F.
Quad Amp Hardware Reference Manua l Getting Started 9 GETTING STARTED Receiving and Handling Inspection up on Receipt Upon the receipt of equipment, inspect all mercha ndise for any indication of damage that may have incurred during shipping and handli ng.
Quad Amp Hardware Reference Manua l Getting Started 1 0 Heat Dissipation The external mounting options (Opt3, Opt3A and Opt 3B) allow the Quad Amplifier to be installed inside a cabinet, with the Quad Amplifier h eat sink mounted external to the cabinet or in an air plenum .
Quad Amp Hardware Reference Manua l Theory of Operatio n 11 THEORY OF OPERATION Operation The Quad Amplifier is a universal 4-axis 3-phase di rect PWM drive which utilizes the latest in smart power technology from the world’s leading vendors a nd the cutting edge algorith ms of the new PMAC2 controller family.
Quad Amp Hardware Reference Manua l Theory of Operation 12 Current Sense Board The Current Sense Board has eight Hall Effect (LEM ) modules for current sense and eight on-board A/D converters that transform four channels of motor current to di gital form.
Quad Amp Hardware Reference Manua l Theory of Operatio n 13 Heat Dissipation The capability of the Quad Amplifier and the IGBT m odules is based upon the heat they can dissipate; the more quickly heat can be removed from the IGBT m odule, the more current it can handle.
Quad Amp Hardware Reference Manua l Theory of Operation 1 4.
Quad Amp Hardware Reference Manua l Installation 15 INSTALLATION Wiring the Quad Amplifier System Quad Amplifier Channel Connections The Quad Amplifier channels must be connected in a particular order for proper operation.
Quad Amp Hardware Reference Manua l Installation 1 6 Non-Standard Quad Amplifier Setup This example shows the Quad Amplifier setup with PMAC axes 1, 2, 7, and 8 are connected to first Quad Amplifier #1 and PMAC Axes 3, 4, 5 and 6 are conne cted to first Quad Amplifier #2.
Quad Amp Hardware Reference Manua l Installation 17 CONNECT TO A C C- 8 F MOT OR GROUNDS 1 23 4 WWWW VVVV UUUU MOTOR CABLES AXIS 1 AXIS 2 AX IS 3 AXIS 4 MOT OR OVERTEMP CONNE CTOR AXIS 1 AXIS 3 AXIS 4.
Quad Amp Hardware Reference Manua l Installation 18 Pin# Symbol Function Description Notes 1 Fc_A1 Input 2 Fc_C1 Input 3 Clk0+ Input A/D Conve rt Clock 4 Conv ert0+ Input A/D Convert Strobe 5 Atddaa1+.
Quad Amp Hardware Reference Manua l Installation 19 Figure 7 Quad Amp Main Circuit Wiring Diagram Main AC Input Power Connect desired main input power to input terminal s marked L1, L2, and L3 (see Figure 7).
Quad Amp Hardware Reference Manua l Installation 2 0 For 460 VAC Operation Jump pin 4 to pin 5. Power is applied to pins 1 and 8 via AC input connector C3. For 480 VAC Operation Jump pin 4 to pin 5 and pin 8 to pin 9. Power is a pplied to pins 1 and 10 via AC input co nnector C3.
Quad Amp Hardware Reference Manua l Installation 21 Bus Power Enable/Emergency Stop CAUTION: Any wiring should be attempted only after th e drive has been isol ated from the main AC supply and 10 to 12 minutes has elapsed to allow the internal bus capacitors to discharge.
Quad Amp Hardware Reference Manua l Installation 22 12 3 3 2 1 Figure 10 Logic I/O Board Jumper and L ED Locations Name Position Description Default E1-E4 IN Shield To Local Ground Open OUT E7 IN Do N.
Quad Amp Hardware Reference Manua l Installation 23 Figure 11 Current Sense Board Jumper and LED Locations Name Position Description Default E1A-E4A IN Enable Serial Fault Data, Phase A Open OUT E1B-E.
Quad Amp Hardware Reference Manua l Installation 2 4 Figure 62 Soft Start Board Jumper, Potent iometer, Test Point, and LED Locations Name Position Description Default E1 1- 2 jumper Inte rnal Power S.
Quad Amp Hardware Reference Manua l Installation 25 Grounding General It is important to follow some precautions to avoi d ground loops or unwanted electrical noise disturbances. • All signal cables must be shielded. • Two or more power wires in the same sleeve must be twisted and shielded.
Quad Amp Hardware Reference Manua l Installation 2 6 Note: The Quad Amplifier has a built-in protecti on against accidentally setting I900 (PWM frequency) too high, and exceeding the P WM input f requency rating of the power blocks. I9n6 For machine interface channel n, I9n6 must be set to 0 to select PWM output format.
Quad Amp Hardware Reference Manua l Installation 27 During this tuning process, P2Setup also determin es the commutation parameters and commands the PMAC appropriately. Power Block Option Continuous Hp Continuous Current (A) Peak Current 2 Sec (A) Max ADC Value 208/230 VAC 5 0.
Quad Amp Hardware Reference Manua l Installation 28.
Quad Amp Hardware Reference Manua l Troubleshoot i ng 29 TROUBLESHOOTING Logic Fault Detection and Fault Codes The Quad Amplifier is capable of detecting and repo rting a variety of fault conditions. These conditions are broken into two types: axis-specific and global.
Quad Amp Hardware Reference Manua l Troubleshoot ing 3 0 Note: Jumpers E1A, E1B, E2A, E2B, E3A, E3B, E4A, E4B must be installed on the current sense board so that the 4-bit faul t code can be accessed at PMAC2 Gate Array Registers. Once such a condition occurs, the PLC notifies the u ser with an on-screen message and then disables itself.
Quad Amp Hardware Reference Manua l Troubleshoot i ng 31 In the case of multiple axis-specific faults on one ax is, the higher-numbered fault shall be indicated. In the case of axis-specific faults on multiple axes, the axis with the higher-numbered fault shall be displayed along with the decimal point indicting its a xis number.
Quad Amp Hardware Reference Manua l Troubleshoot ing 32 Motor moves after a command is issued but under volt age fault comes on sh ortly after. Also, the Soft Start resistor heats up (and possibly b urns). Verify if the bus voltage sags when the motor is c ommanded t o move.
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 33 ILLUSTRATED REPAIR PARTS LIST Purpose This chapter contains the Repair Parts List (RPL) for the 4-Axis Digital Amplifier (Quad Amplifier ). The RPL identifies the customer replaceable units (CRUs) of Quad Amplifier with an illustration and a Group Assembly Parts List (GAPL).
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 3 4 Figure 12 Delta Tau Data Systems 4 Axis Digital Amplifier.
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 35 Figure And Index Number Part Number Description 1 2 3 4 5 6 7 Qty Per Assy Manu- facturer Part Number 7-1 500-602645-103 QUAD Digit.
Quad Amp Hardware Reference Manua l Illustrated Repair Parts List 3 6 Figure And Index Number Part Number Description 1 2 3 4 5 6 7 Qty Per Assy Manu- facturer Part Number -270 014-030 M03- HSM 3 Pos. Pl ug (P2) 1 Amp 1- 480700-0 -280 014-00 MF04- 0HM 4 Pos.
An important point after buying a device Delta Tau 3Ax-602646-xUxx (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Delta Tau 3Ax-602646-xUxx yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Delta Tau 3Ax-602646-xUxx - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Delta Tau 3Ax-602646-xUxx you will learn all the available features of the product, as well as information on its operation. The information that you get Delta Tau 3Ax-602646-xUxx will certainly help you make a decision on the purchase.
If you already are a holder of Delta Tau 3Ax-602646-xUxx, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Delta Tau 3Ax-602646-xUxx.
However, one of the most important roles played by the user manual is to help in solving problems with Delta Tau 3Ax-602646-xUxx. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Delta Tau 3Ax-602646-xUxx along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center