FEATURES High efficiency: 89% @ 5V/ 15A Size: 58.4mm x 22.8mm x 9.2mm (2.30”x0.90”x0.36”) Industry standard pin out 18~75V extremely wide 4:1 input r ange Fixed frequency ope.
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V out unless otherw ise noted.) PA R A M E T E R NOTES and CONDITIONS E36SR05015 (St andard) Min.
ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C. DS_E36SR05015_010 42008 3 Figure 2: Power dissipation vs. load current for min imum, nominal, and max i mum input voltage at 25°C.
ELECTRICAL CHARACTERISTICS CUR VES Figure 4: T urn-on trans ient at full rated load current (CC mode) (5ms/div). Vin=48V .T op T rac e: V out, 2V/div; Bottom T race: ON/OFF input, 5V/div . Figure 5: T urn-on transient at zero load current (5ms/ div). Vin=48V .
ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (50%-25% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF , tantalum cap acitor and 1 µF ceramic cap acitor. T op T race: Vout (100mV/div , 200us/div), Bottom T race: I out (5A/div).
ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at 48Vin and 15A output current (20 mA/ div , 2us/div). Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 13: Output voltage noise and ripple measur ement test setup.
The input source must be insulated f rom the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
DS_E36SR05015_010 42008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode).
FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, the modules may be connected wit h an external resistor betwee n the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
DS_E36SR05015_010 42008 10 THERMAL CONSIDERA TIONS Thermal management is an important part of the syst em design. To ensure p roper, reliable operation, sufficie nt cooling of the power mod ule is needed over the entire temperature range of the modul e.
P I C K A N D P L A C E L O C A T I O N S U R F A C E - M O U N T T A P E & R E E L RECOMMENDED P AD LA YOUT (SMD) DS_E36SR05015_010 42008 11.
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
MECHANICAL DRA WING Surface-mount module Through-hole module Pin No. Name Function 1 2 3 4 5 6 7 8 +Vin ON/OFF -Vin -V out -SENSE TRIM +SENSE +V out Positive input voltage Remote ON/OFF Negative input.
MECHANICAL DRA WING (WITH HEA TSPREADER) THROUGH-HOLE MODULE DS_E36SR05015_010 42008 14.
DS_E36SR05015_010 42008 15 P ART NUMBERING SYSTEM E 36 S R 050 15 N R F A T ype of Product Input V o ltage Number of Output s Product Series Output V o ltage Output Current ON/OFF Logic Pin Length/T ype Option Code E- Eighth Brick 36-18~75V S- Single R- Regular 050- 5.
An important point after buying a device Delta Electronics Series E36SR (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Delta Electronics Series E36SR yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Delta Electronics Series E36SR - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Delta Electronics Series E36SR you will learn all the available features of the product, as well as information on its operation. The information that you get Delta Electronics Series E36SR will certainly help you make a decision on the purchase.
If you already are a holder of Delta Electronics Series E36SR, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Delta Electronics Series E36SR.
However, one of the most important roles played by the user manual is to help in solving problems with Delta Electronics Series E36SR. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Delta Electronics Series E36SR along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center