Instruction/ maintenance manual of the product PAC160 DeLonghi
Go to page of 18
PA C 160 PA C 160 • Use and maintenance manual . . . . pag. 4 • Mode d’emploi et d’entr etien . . . . . pag. 19 • Instrucciones de uso . . . .
D ear Customer , Thank you for purchasing an appliance made by De’ Longhi, the interna- tional leader in portable air conditioning units. Thanks to our years of experi- ence all around the world we are constantly improving the quality and per- for mance of Pinguino.
3 1 2 3 4 5 6 7 9 10 12 13 15 16 14 17 8 • D escription • D escription • Descriptción • D escrizione • ACCESSOR Y -SET • ACCESSOIRES A CCESSOIRES • A CCESSORI • CONTR OL P ANEL • P .
4 Impor tant S af e-guar ds When using electrical appliances, basic safety precautions should always be taken, with particular reference to the following: - Read all instructions. -T o protect against fire, electric shock and personal injury, do not immerse cable, plug or appliance in water or other liquid.
5 ENGLISH D uring the summer , optimum comfort is achieved with a temperature of between 75-80°F (24- 27°C) and about 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located.
6 DESCRIPTION MODEL 1) Air discharge grill 2) Control Panel 3) Wheels 4) Handles 5) Housing for air exhaust hose 6) Cord winder 7) Air intake grill 8) Rating plate 9) W ater collection tank 10) Water .
7 ENGLISH 1 2 When positioning the appliance, always ensure that nothing obstructs the intake and discharge of air AIR CONDITIONING WITHOUT PERMANENT INST ALLA TION Only a few simple steps are necessary to obtain the comfort offered by Pinguino. • Fit the air exhaust hose (14) in its housing (5) at the rear of the appliance as shown in fig.
8 Pinguino is equipped with an adjustable win- dow bracket 18 . If you have a sliding window, place the bracket on the window sill, extend the bracket fully within the window frame and lower the window onto the bracket. Insert the nozzle of the exhaust hose into the slot, then connect the hose to the air conditioner (Fig.
9 ENGLISH Setting up AIR CONDITIONING WITH SEMI-PERMA- NENT INST ALLA TION If desired, Pinguino can also be installed on a semi-per manent basis fig. 7. • Fit the flange (13) supplied to the hole. • Fix the hose (14) in the housing at the rear of the appliance (fig 1) • Fit the end of the hose to the flange (15) as shown in fig.
10 D escription of the control panel ELECTRICAL CONNECTION Before plugging in check that: • the mains supply corresponds to the value shown in the specifications table; • the socket and the mains .
11 ENGLISH Oper ation SWITCHING THE APPLIANCE ON Connect the appliance to the mains supply. On the display two lines will appear indicating Stand-by mode Press the ON/OFF button ( A ) and then the MODE button until the relevant function indicator appears viz.
12 Once the dehumidifying function has been selected, the fan speed cannot be changed. The appliance will automatically select the correct fan mode. VENTILA TION Adjust the fan speed by pressing the “F AN” (Q) button, as illustra- ted in the air conditioning function.
13 ENGLISH Oper ation SELF-DIAGNOSIS The appliance is equipped with a self-diagnosis system which identifies any operating problems. IF THE DISPLA Y SHOWS… ….WHA T SHOULD YOU DO? H H P P HIGH PRESSURE Insert and re-insert the plug. If the problem persists, call the service centre.
14 Follow these recommendations to achieve maximum efficiency from your air conditio- ning unit: • Close the doors and windows in the room where the unit is functioning. The only exception is in the case of installation throu- gh a hole in the wall.
15 ENGLISH 1 2 Before cleaning or maintenance, switch of f the appliance by pressing the ON/OFF button (A) and always unplug it from the mains supply. CLEANING THE EXTERNAL UNIT We recommend cleaning the appliance with a slightly damp cloth. It should then be dried.
16 Tr oubleshooting PROBLEM CAUSES REMEDY The air-conditioner does not work • the power is off • the appliance is not plugged in • Plug it in The air-conditioner works only for a short time • .
ENGLISH 17 T echnical specification TECHNICAL SPECIFICA TION Power supply see rating plate Max. absorbed power in air conditioning “ Max. absorbed power when dehumidifying “ Refrigerating capacity* “ Number of fan speeds 2 + silent Max. air flow 460 m 3 /h Dimensions of internal unit: • width 452 mm 17.
18 LIMITED W ARRANTY We warrant each DE’LONGHI AIR-CONDITIONER to be free from defects in material and work- manship. Our obligation under this warranty is to provide one year parts and labor free f.
An important point after buying a device DeLonghi PAC160 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought DeLonghi PAC160 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data DeLonghi PAC160 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, DeLonghi PAC160 you will learn all the available features of the product, as well as information on its operation. The information that you get DeLonghi PAC160 will certainly help you make a decision on the purchase.
If you already are a holder of DeLonghi PAC160, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime DeLonghi PAC160.
However, one of the most important roles played by the user manual is to help in solving problems with DeLonghi PAC160. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device DeLonghi PAC160 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center