Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Product Identification Figure 4 – Models 3E218F and 3E219F Pow.
3 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F General Safety Information (Continued) Figure 5 - Cr oss Section.
5 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Assembly (For Models 3E218F and 3E219F Only) These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Never service heater while it is plugged in, operating, or hot. Sever e burns and electrical shock can occur . Maintenance UPPER SHELL REMOV AL 1.
7 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Maintenance (Continued) 5. Remove pressure gauge. Replace pressure gauge plug in filter end cover . Pump Model Pressur e 2E510F 3.0 psi 2E511F 3.
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Maintenance (Continued) IGNITOR 1. Remove upper shell and fan guard (See page 6). 2. Remove fan (See page 6). 3. Remove 4 side cover screws with a 5/16" nut driver .
9 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Maintenance (Continued) NOZZLE 1. Remove upper shell (See page 6). 2. Remove fan (See page 6). 3. Remove fuel and air line hoses from nozzle assembly (See Figure 18 or 19).
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Figure 25 - Gap Adjusting Scr ew Locations Maintenance (Continued) 5. Remove pump plate. 6. Remove rotor , insert, and blades.
11 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Never service heater while it is plugged in, operating, or hot.
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
13 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Ref. Part 2E510F 2E511E No. Description Number Qty . Qty. Ref. Part 2E510F 2E511F No. Description Number Qty . Qty. Ref. Part 2E510F 2E511F No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
15 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® 1 Handle M51104-01 1 1 2 Upper Shell 098511-67 1 1 3 #10-16 x 3/4" Screw * M11084-29 2.
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
17 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® (*) Standard hardware item, available locally . ( ∆ ) Not shown. (†) Not available as an assembly , see page 13. Ref. Part 2E510E 2E511E No.
Dayton Operating Instructions and Parts Manual 18 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Figure 33 - Repair Parts Illustration for Model 3E219F 1 2 3 23.
19 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Ref. Part No. Description Number Qty . Ref.
Dayton Operating Instructions and Parts Manual 20 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Repair Parts List for Handle and Wheel Gr oup Models 3E218F and 3E219F 3 4 5 8 7 6 2 1 Ref. Part Number No. Description 3E218F 3E219F Qty.
21 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Wiring Diagram Figure 35 - Wiring Diagram, Models 2E510F and 2E511F Blue Photocell Power Pl.
Dayton Operating Instructions and Parts Manual 22 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot.
23 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Heater ignites but ignition control assembly shuts heater off after a short period of time 1. Pump pressure incorrect 2. Dirty air intake, air output, and/or lint filter 3.
Dayton Operating Instructions and Parts Manual 24 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 111166-01 Rev . A 04/03 Version B - For Reduction G016.
An important point after buying a device Dayton 5S1792 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dayton 5S1792 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dayton 5S1792 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dayton 5S1792 you will learn all the available features of the product, as well as information on its operation. The information that you get Dayton 5S1792 will certainly help you make a decision on the purchase.
If you already are a holder of Dayton 5S1792, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dayton 5S1792.
However, one of the most important roles played by the user manual is to help in solving problems with Dayton 5S1792. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dayton 5S1792 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center