Instruction/ maintenance manual of the product 3VG79A Dayton
Go to page of 16
Operating Instructions & Parts Manual 3VG79A Dayton Portable For ced Air Heater Description Dayton Model 3VG79A is a 200,000 Btu/Hr heater . This heater uses only Kerosene or No.
Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heater ® 3VG79A Lower Shell Hot Air Outlet Fan Guard Fuel T ank Flame-out Control Reset Button Side Cover Fuel Cap Figure 2.
Dayton Operating Instructions and Parts Manual 3 Model 3VG79A Version B - For Reduction G016.J ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heater ® 3VG79A General Safety Information (Continued) Theory of Operation Fuels Use only Kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
Dayton Operating Instructions and Parts Manual 5 Model 3VG79A Version B - For Reduction G016.J ® Front Handle Rear Handle Wheel Support Frame Hot Air Outlet Fuel T ank Flange Screw Air Inlet Assembly This model is furnished with wheels and handles. Wheels, handles, and the mounting hardwar e are found in the shipping carton.
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heater ® 3VG79A FAN IMPORT ANT : Remove fan from motor shaft before r emoving motor from heater . The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell ( See Figur e 6).
Dayton Operating Instructions and Parts Manual 7 Model 3VG79A Version B - For Reduction G016.J ® Figure 10 - Adjusting Pump Pr essure Pressure Gauge Side Cover Bushing, Lower Fuel Line, and Fuel Filter Figure 11 - Fuel Filter Removal Fuel V alve Fitting High V oltage.
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heater ® 3VG79A Air Line Hose Screw Combustion Chamber Burner Head Spark Plug Wire Spark Plug Fuel Line Hose NOZZLE 1. Remove upper shell (See page 6). 2. Remove fan (See page 6).
Dayton Operating Instructions and Parts Manual 9 Model 3VG79A Version B - For Reduction G016.J ® Sandpaper Gap Adjusting Screw Gap Adjusting Screw .003"/.004" Gap Measured With Feeler Gauge Rotor Blade 5. Remove pump plate. 6. Remove rotor , insert, and blades.
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heater ® 3VG79A For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 11 Model 3VG79A Version B - For Reduction G016.J ® Ref. Part 2E510D 2E511D No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heater ® 3VG79A Figure 24 - Replacement Parts Illustration 1 2 3 4 5 6 7 8 23 19 9 10 16 11 12 15 45 25 26 27 24 28 29 20 .
Dayton Operating Instructions and Parts Manual 13 Model 3VG79A Version B - For Reduction G016.J ® 3VG79A Ref. Part No. Description Number Qty . Ref. Part No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heater ® 3VG79A Replacement Parts List for Handle and Wheel Group Ref. Part No.
Dayton Operating Instructions and Parts Manual 15 Model 3VG79A Version B - For Reduction G016.J ® T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur .
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heater ® 3VG79A Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. 105559-01 Rev . B 09/99 Version B - For Reduction G016.J ® NOT A UPC LIMITED WARRANTY DA YTON ONE-YEAR LIMITED WARRANTY .
An important point after buying a device Dayton 3VG79A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dayton 3VG79A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dayton 3VG79A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dayton 3VG79A you will learn all the available features of the product, as well as information on its operation. The information that you get Dayton 3VG79A will certainly help you make a decision on the purchase.
If you already are a holder of Dayton 3VG79A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dayton 3VG79A.
However, one of the most important roles played by the user manual is to help in solving problems with Dayton 3VG79A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dayton 3VG79A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center