Instruction/ maintenance manual of the product 3E219C Dayton
Go to page of 24
Operating Instructions & Parts Manual Dayton Portable Oil-Fir ed Heaters ® Form 5S1792 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the pr oduct described. Protect yourself and others by observing all safety information.
Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 101421 Amperage Model Electrical Input (during normal run) 2E510D 120 V olt/60 Hertz 2.0 2E511D 120 V olt/60 Hertz 2.0 3E218D 120 V olt/60 Hertz 4.5 3E219C 120 V olt/60 Hertz 4.
3 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 101421 General Safety Information (Continued) Figure 5 - Cr oss Section Operational View Clean Heated Air Out Air.
5 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® ASSEMBL Y (For Models 3E218D and 3E219C Only) These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 101421 Figure 8 - Flame-out Contr ol Reset Button, Models 3E218D and 3E219C Operation (Continued) 5. Plug extension cord into standard 120 volt/60 hertz, three-hole, grounded outlet.
7 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Figure 12 - Fan Cr oss Section, Model 3E219C AIR OUTPUT , AIR INT AKE, AND LINT FIL TERS 1. Remove upper shell (see Figure 10). 2. Remove filter end cover screws using 5/16" nut-driver .
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 101421 Maintenance (Continued) Side Cover Upper Fuel Line Fuel Filter Figure 17 - Fuel Filter Removal, Models 2E510D and 2E511D Side Cover Upper Fuel Line Figure 18 - Fuel Filter Removal, Models 3E218D and 3E219C SP ARK PLUG (Models 2E510D and 2E511D) 1.
9 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Spark Plug Wire Spark Plug Burner Head Figure 22 - Spark Plug Removal, Models 3E218D and 3E219C Maintenance (Continued) 5. Clean and regap spark plug elec- trodes to .
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 101421 Maintenance (Continued) NOZZLE (Models 3E218D and 3E219C) 1. Remove upper shell (see page 6). 2. Remove fan (see page 6). 3. Remove fuel and air line hoses from burner head.
11 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® NOTE : If rotor is still binding, proceed as follows. 13. Perform steps 1 through 6 (see page 10). 14. Place fine grade sandpaper (600 grit) on flat surface.
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 101421 For Replacement Parts, call 1-800-323-0620 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
13 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Replacement Parts List Models 2E510D, 2E511D, 3E218D and 3E219C Portable Oil-Fir ed Heaters 2E510D, 2E511D, 3E218D, and 3E219C Ref. Part 2E510D 2E511D No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 101421 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
15 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® 2E510D and 2E511D (*) Standard hardware item, available locally .
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 101421 For Replacement Parts, call 1-800-323-0620 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
17 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® 3E218D Replacement Parts List Model 3E218D Portable Oil-Fir ed Heater (*) Standard hardware item, available locally . ( ∆ ) Not shown. (†) Not available as an assembly , see pages 14 and 15.
Dayton Operating Instructions and Parts Manual 18 Dayton Portable Oil-Fir ed Heaters ® 101421 For Replacement Parts, call 1-800-323-0620 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
19 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® 3E219C Replacement Parts List Model 3E219C Portable Oil-Fired Heater Ref. Part 3E219C No. Description Number Qty . Ref. Part 3E219C No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 20 Dayton Portable Oil-Fir ed Heaters ® 101421 Replacement Parts List for Handle and Wheel Group Models 3E218D and 3E219C Figure 39 - Handle and Wheel Assembly 3 4 5 8 7 6 2 1 Ref. Part Number No. Description 3E218D 3E519C Qty .
21 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Wiring Diagrams Figure 41 - Wiring Diagram for Models 3E218D and 3E219C White Black Blue Green Pow.
Dayton Operating Instructions and Parts Manual 22 Dayton Portable Oil-Fir ed Heaters ® 101421 T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur .
23 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® __________________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 2E510D, 2E511D, 3E218D, and 3E219C Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 101421-01 Rev . C 03/98 Version B - For Reduction G016.J ® Dayton Portable Oil-Fir ed Heaters LIMITED WARRANTY Dayton One-Year Limited Warranty.
An important point after buying a device Dayton 3E219C (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Dayton 3E219C yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Dayton 3E219C - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Dayton 3E219C you will learn all the available features of the product, as well as information on its operation. The information that you get Dayton 3E219C will certainly help you make a decision on the purchase.
If you already are a holder of Dayton 3E219C, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Dayton 3E219C.
However, one of the most important roles played by the user manual is to help in solving problems with Dayton 3E219C. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Dayton 3E219C along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center