Instruction/ maintenance manual of the product DS6500-100-011 Datalogic Scanning
Go to page of 36
DS6500 INSTA LLA TION QUICK REFERENCE.
CONTENTS DS6500-100-010 M ASTER/SLAVE MODEL ........................................................................................................... 1 DS6500-100-011 PROFIBUS MODEL ...................................................................
DS6500 MASTER/SLAVE MODEL DS6500-100-010 MASTER/SLAVE MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Main/Aux.
DS6500 MASTER/SLAVE MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage T.
DS6500 MASTER/SLAVE MODEL The details of the connector pins ar e indicated in the following table: 25-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable.
DS6500 MASTER/SLAVE MODEL Connectivity: Point-to-Point Layout DS6500 CAB-600X C-BOX 100 Local Host *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout E N T < < E N T < < *P.S. *P.S. Gryphon DS4600A DS4600A DS6500 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 A U X MAIN *P.
DS6500 MASTER/SLAVE MODEL Multiplexer Layout E N T < < E N T < < *P.S. *P.S. DS4600A DS4600A DS6500 PWR-120 CAB-600X C-BOX 100 C-BOX 100 C-BOX 100 MX4000 #0 1 #31 #1 Local Host 1 RS485 HD M ain Interface * P.S. (Presence Sensor) connect ed to External Trigger/PS input.
DS6500 MASTER/SLAVE MODEL Local Lonworks Netw ork CAB-60XX CAB-610X BTK-6000 C-BOX 100** Master Encoder*** BTK-6000 Slave 1 *P.S. Local Host CAB-63XX PWR-120 Small Synchronized Network w ith 2 Readers * P.S. (Presence Sensor) connect ed to External Trigger/PS input.
DS6500 MASTER/SLAVE MODEL Large Synchronized Ne tw ork ** * * P.S. (Presence Sensor) connect ed to External Trigger/PS input. ** Encoder connected to IN2/ENC input.
DS6500 PROFIBUS MODEL DS6500-100-011 PROFIBUS MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C Prof ibus 9- pin Female Connector (whit e) 1 Lonworks 9-pin Female Con nector 2 Ma in/Aux.
DS6500 PROFIBUS MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Tempe.
DS6500 PROFIBUS MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (refe.
DS6500 PROFIBUS MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.
DS6500 PROFIBUS MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.
DS6500 ETHERNET MODEL DS6500-100-012 ETHERNET MODEL Figure A Laser Beam Output W indow 1 Figure B Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Figure C RJ45 Modular Connect or f or Ethe rnet Inter fac e 1 Lonworks 9-pi n Female Con nector 2 Ma in/Aux.
DS6500 ETHERNET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Tempe.
DS6500 ETHERNET MODEL 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RX AU X Receive data of auxiliary RS232 (refe.
DS6500 ETHERNET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Netw ork DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.
DS6500 ETHERNET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.
DS6500 DEVICENET MODEL DS6500-100-015 DEVICENET MODEL Figure A Laser Beam Output W indow 1 Figure B Figure C Programming Keyp ad 1 Phase On LED (Yellow) 3 TX Data LED (Gree n) 2 Pow er On L ED (Re d) 4 LCD Display 5 Main/Aux.
DS6500 DEVICENET MODEL SOFTWA RE FEA TURES ENVIRONMENTA L FEA TURES Interleaved 2/5 Readable Codes Code 39 standard Operating Temperature 0° to +40 °C (+32 to +104 °F) Codabar Code 128 Storage Temp.
DS6500 DEVICENET MODEL The details of the connector pins ar e indicated in the following table: 26-pin D-Sub Connector Pinout Pin Name Function Chassis - internally connected to GND 1 CHASSIS Cable sh.
DS6500 DEVICENET MODEL Connectivity: Point-to-Point Layout Remote Host Fieldbus Network DS6500 C-BOX 100 CAB-601X *P.S. PG6000 * P.S. (Presence Sensor) connect ed to External Trigger/PS input. Pass Through Layout Remote Host E N T < < E N T < < *P.
DS6500 DEVICENET MODEL Local Lonworks Netw ork Remote Host Fieldbus Network Master Slave 2*** Slave 1*** C-BOX 100** CAB-610X CAB-610X CAB-60XX P.S.* CAB-610X Encoder**** CAB-610X CAB-610X CAB-63XX BTK-6000 Slave 3*** Slave 5*** Slave 4*** PWR-240 CAB-63XX Fieldbus Small Synchronized Network * P.
DS6500 OSCILLATING MIRROR MODEL DS6500-105-0XX OSCILLATING MIRROR MODEL Figure A Laser Beam Output W indow 1 1 Oscillating mirror models are used when coverage of a lar ge reading area is required, mainly in picket fence applications. The DS6500 scanner mounts a dedicated optic head with int egrated oscillating mirror driven by a linear motor.
DS6500 OSCILLATING MIRROR MODEL In the above case, the zone where the scan line is perpendicular to the reflec ting surface corresponds to a neutral zone at the center of the reading field. The mirror can be deflected up to 40°. Oscillation with res pect to the output window medi an axis is asymmetrical (see figure below).
COMMON FEATURES COMMON FEATURES C-BOX 100 Pinout for DS6500: The table below gives the pinout of the C-BOX 100 terminal block connecto rs. Use this pinout when the DS6500 reader is connected in a netw.
COMMON FEATURES Mechanical Installation: The DS6500 reader can be positioned and in stalled in the best way possible as a result of the Step-A-Head TM feature.
COMMON FEATURES Typical Installations: Standard Installation The DS6500 scanner is mounted on the ST -237 106° mounting bracket w hic h guarantees a built-in Skew angle ( S in the figure below) of 16° w ith respect to the frame plane (typically the Skew angle should be between 10° - 20°).
COMMON FEATURES Minimum Code Height for A CR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1. 5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.25 10 12 14 16 18 20 7 9 10 12 13 15 0.30 12 14 15 17 19 21 8 9 11 12 14 15 0.33 13 14 16 18 20 22 8 10 11 13 14 16 0.38 14 16 18 19 21 23 9 11 12 14 15 17 0.
COMMON FEATURES Reading Diagrams: In the following reading diagrams (0,0) is t he center of the laser beam output w indow . DS6500-100-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.
COMMON FEATURES Reading Diagrams: DS6500-200-0XX CONDITIONS Code = Interleaved 2/5 o r Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 14 (in) 20 26 32 0 35 50 6 5 80 95 (cm ) 110 38 44 140 56 (in) (c m) 0 -15 -30 -45 -12 -18 -6 0 -60 -24 -75 -30 15 6 30 12 0.
COMMON FEATURES User Interface: RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connec tor Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How T.
COMMON FEATURES Compliance: Laser Safety Figure A Laser Saf ety Label 1 Identif ication Label 2 Figure B W arning and Device Class Label 1 Figure C Laser Safety Label 1 1 2 1 1 The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations.
COMMON FEATURES The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulati ons.
DATALOGIC S.p.A., DATALOGIC S.p.A., 05 Via Candini, 2 Via Candini, 2 40012 - Lippo di Calderara 40012 - Lippo di Calderara Bologna - Italy Bologna - Italy dichiara che dichi ara che declares that the .
An important point after buying a device Datalogic Scanning DS6500-100-011 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Datalogic Scanning DS6500-100-011 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Datalogic Scanning DS6500-100-011 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Datalogic Scanning DS6500-100-011 you will learn all the available features of the product, as well as information on its operation. The information that you get Datalogic Scanning DS6500-100-011 will certainly help you make a decision on the purchase.
If you already are a holder of Datalogic Scanning DS6500-100-011, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Datalogic Scanning DS6500-100-011.
However, one of the most important roles played by the user manual is to help in solving problems with Datalogic Scanning DS6500-100-011. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Datalogic Scanning DS6500-100-011 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center