Instruction/ maintenance manual of the product 5500 Datalogic Scanning
Go to page of 36
QRG Addendum Falcon ® 5500 RFID Mobile Hybrid Computer.
PSC Inc 959 T err y Street Eugene, Oregon 97402 T elephone: (541) 683-5700 F ax: (541) 345-7140 An Unpublished W ork - All r ights reserved. No par t of the contents of this documentation or the procedures described therein may be reproduced or trans mitted in any f orm or by any means without prior written per mission of PSC Inc.
Addendum i Table of Contents Overview .................................................................................. .................................... 1 Introduction ........................................................................ .....
Table of Contents ii Falcon ® 5500 RFID Mobile Hybrid Computer NOTES.
Addendum 1 Falcon ® 5500 RFID Mobile Hybrid Computer Overview This document covers the following topics: Getting Start ed • Enabling RFID on pa ge 2 • Reading RFID T ags on page 3 Configuration S.
Getting Started 2 Falcon ® 5500 RFID Mobile Hybrid Computer Introduction The F alcon 5500 is a F alcon 4420 Windo ws ® CE Color Mobile Computer mounted with a special RFID unit.
Getting Started Addendum 3 4. In the Pistol T rigger column, select RFID . 5. T a p OK. F or information on other RFID configuration options, see Configuration Set- tings on page 8 . Reading RFID Tags For tag read demo pu rposes: Once you have enabled the F alcon to read RFID tags, complete the following steps: 1.
Getting Started 4 Falcon ® 5500 RFID Mobile Hybrid Computer 5. The RFID tag data is entere d into the application. 6. When the read is finished, the front LED turns off and a final beep is heard, indicating that the operation is complete. The RFID Antenna (in the RFID unit) should be positioned to face the tag location.
RFID Electrical Considerations Addendum 5 RFID Electrical Considerations Operating time U nder normal operating conditions, the RF ID batter y will last l onger than the F alcon batter y . Extended continuous oper ation may result in the RFID batter y discharging before the F alcon battery .
RFID Electrical Considerations 6 Falcon ® 5500 RFID Mobile Hybrid Computer LEDs/Indicators RFID Battery Charge LEDs These indicators are visible on the back of the RFID pod. The red LED is on when the unit is in a dock and the RFID batter y is charging.
RFID Electrical Considerations Addendum 7 Figure 3. Falcon 550 0 Dock Falcon 5500 Dock Use only the correct battery ch argers and doc ks with the Falcon 5500 RFID . The technology used f or this model is incomp atible with other PSC Falcon char gers and docks, inc luding the Falcon 4410/4420 color and monochr ome models.
Configuration Settings 8 Falcon ® 5500 RFID Mobile Hybrid Computer Configuration Settings See Configuration Examples on page 12 for samples of optimized settings for different usages. R efer to the Falcon 4400 Series PRG for information about setting other configuration items.
Configuration Settings Addendum 9 RFID Settings 1. Go to Star t > Settings > Control Pan e l . Double-tap the Decoding icon. 2. Select Configure > RFID . 3. Choose one of the available options. Report Settings In the RFID Decoding P roperties, do the following to view or modify Report S et- tings: 1.
Configuration Settings 10 Falcon ® 5500 RFID Mobile Hybrid Computer Power 1. U nder Decoding Properties , go to Configure > RFID > Po wer 2. Enable/disable Gr owing P ower by selecting the checkbox. When dis- abled, a constant level of RF pow er is output when reading tags.
Configuration Settings Addendum 11 • New T ag Timeout: The amount of time to wait between tags before painting will automatically stop. This is the maximum amount of time spent waiting for new tags after a tag has been read.
Configuration Settings 12 Falcon ® 5500 RFID Mobile Hybrid Computer Configuration Examples The following examples illustrate ways to optimize RFID settings for specific situations. Reading tagged items fr om an entire shelf 1. P ress the trigger and move across the items on the shelf.
Configuration Settings Addendum 13 Class 1 Gen 2 Q value Q value sets the number of response slots available for the tags being inventoried (number of slots = 2Q). I t is actively managed during an inventor y round, but starting wi th an appropriate Q decreases the time necessary to perform an inventory .
About RFID Tags 14 Falcon ® 5500 RFID Mobile Hybrid Computer About RFID Tags RFID Antenna When attempting to utilize the RFID re ad functionality of the F alcon 5500 RFID unit it is important to note that the antenna is linearly polarized.
About RFID Tags Addendum 15 Tag Orientation Factors Affecting Performance • W ater or water-based products will inhibit (absorb) the signal. • M etal surfaces near the tags may affect performance. • Misuse of tags (i.e. bending the tag antenna) could cause the tags to become dysfunctional.
Configuration Parameters 16 Falcon ® 5500 RFID Mobile Hybrid Computer Configuration Parameters The following table lists the configurati on parameters whi ch have been added to support RFID.
Configuration Parameters Addendum 17 T ag Read Beep To n e Adjusts the pitch of th e tag read beep fr equency . 0D20 V alue 00 - 08 (00 = Low est; 07 = Highest; 08 = User Def .) 00 00 00 T ag Read Beep Durat ion Deter mines th e duration of a tag read beep .
Configuration Parameters 18 Falcon ® 5500 RFID Mobile Hybrid Computer To t a l Read Timeout Sets the dura tion of the read operation before it stops. This only applies to reads st ar ted by a ph ysical trigger .
RFID Programming Labels Addendum 19 RFID Programming Labels CLASS 0 ENABLE O n O f f CLASS 1 ENABLE O n O f f CLASS 1 GENERATION 2 ENABLE O n O f f TAG READ BEEP ENABLE O n O f f READ POWER MODE G r o.
RFID Programming Labels 20 Falcon ® 5500 RFID Mobile Hybrid Computer TAG READ BEEP TONE 0 0 0 4 0 1 0 5 0 2 0 6 0 3 0 7 TAG READ BEEP DURATION 0 0 0 2 0 1 0 3 */ / 0 D 2 0 0 0 F F 3 E * */ / 0 D 2 0 .
RFID Programming Labels Addendum 21 MINIMUM READ POWER 1 3 % 6 3 % 2 5 % 7 5 % 3 8 % 8 8 % 5 0 % 1 0 0 % MAXIMUM READ POWER 1 3 % 6 3 % 2 5 % 7 5 % 3 8 % 8 8 % 5 0 % 1 0 0 % */ / 0 D 2 9 0 1 F F 3 E *.
RFID Programming Labels 22 Falcon ® 5500 RFID Mobile Hybrid Computer CLASS 1 GENERATION 2 Q 0 0 0 9 0 3 1 2 0 6 1 5 * / / 0 D 3000F F3 E* * / / 0 D 3009F F3 E * * / / 0 D 3003F F3 E* * / / 0 D 3012F .
RFID Programming Labels Addendum 23 TOTAL READ TIMEOUT Infinite 10 seconds 25 seconds 50 seconds 70 seconds 85 seconds 99 seconds * / / 0 D 2 C 0000F F3 E * * / / 0 D 2 C 1000F F3 E * * / / 0 D 2 C 25.
RFID Programming Labels 24 Falcon ® 5500 RFID Mobile Hybrid Computer NEW TAG READ TIMEOUT Infinite 1000 2500 5000 7000 8500 9999 * / / 0 D 2 D 0000F F3 E * * / / 0 D 2 D 1000F F3 E * * / / 0 D 2 D 25.
RFID Programming Labels Addendum 25 MINIMUM TAG READ COUNT Inifinite 1 50 100 150 200 250 * / / 0 D 2E 000 0F F 3 E * * / / 0 D 2E 000 1F F 3 E * * / / 0 D 2E 005 0F F 3 E * * / / 0 D 2E 0100F F 3 E *.
RFID Programming Labels 26 Falcon ® 5500 RFID Mobile Hybrid Computer READ REPORT FREQUENCY Inifinite 01 50 100 150 200 250 * / / 0 D 2F 0000F F3 E * * / / 0 D 2F0001 F F3 E * * / / 0 D 2F0050 F F3 E .
Safety Information Addendum 27 Safety Information FCC Statement This device complies with part 15 of t he FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interfer ence received, including interference that may caus e undesired operation.
Safety Information 28 Falcon ® 5500 RFID Mobile Hybrid Computer NOTES.
Safety Information Addendum 29 NOTES.
Safety Information 30 Falcon ® 5500 RFID Mobile Hybrid Computer NOTES.
.
Asia P acific PSC Hong K ong Hong K ong T elephone: [852]-2-584-6210 F ax: [852]-2-521-0291 A ustralia PSC Asia P acific Pty Ltd. Nor th Ryde, A ustralia T elephone: [61] 0 (2) 9878 8999 F ax: [61] 0 (2) 9878 8688 France PSC S.A.R.L. LES ULIS Cedex, F rance T elephone: [33].
An important point after buying a device Datalogic Scanning 5500 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Datalogic Scanning 5500 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Datalogic Scanning 5500 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Datalogic Scanning 5500 you will learn all the available features of the product, as well as information on its operation. The information that you get Datalogic Scanning 5500 will certainly help you make a decision on the purchase.
If you already are a holder of Datalogic Scanning 5500, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Datalogic Scanning 5500.
However, one of the most important roles played by the user manual is to help in solving problems with Datalogic Scanning 5500. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Datalogic Scanning 5500 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center