Instruction/ maintenance manual of the product QuickScan Lite QW2100 Datalogic
Go to page of 324
QuickScan TM Lite Q W2100 General P urpose C or ded Handheld Linear Imager Bar C ode Reader Prod uc t R efe ren ce G uid e.
Datalogic Scanning , Inc. 959 T erry Street Eugene , Oregon 9740 2 USA T elephone: ( 541) 683-5700 F a x: (541) 345-7140 An Unpublished W ork - All rights reserved .
Product Reference Guide 1 T able of C on tents Chapter 1. Introduction . ............... ............... ............... ................ ............... ............... ............... ............... ............... ............... ......... 1 About this Guide .
2 QuickScan TM Lite QW2100 Flash Off Time .............................. ............................. ............................. ........................ ......... ............................. ........................ .......................... 34 Stand Mode Sensitivity .
Product Referenc e Guide 3 Label ID Symbology Sele ction .................. ............................. ............................. ...................... ........... ............................. ........................ ...... 72 Set Global Mid Label ID C haracter(s) .
4 QuickScan TM Lite QW2100 P2 Add-Ons Mi nimum Reads ...................... ............................. ............................. ...................... ...... ............................. ............................. .. 115 P5 Add-Ons Mi nimum Reads .
Product Referenc e Guide 5 I 2 of 5 Minimum Reads ........................ ............................. ............................. ...................... .. ............................. ............................. ................ 156 I 2 of 5 Decoding Level .
6 QuickScan TM Lite QW2100 Standard 2 of 5 Dec oding Level ......................... ............................. ............................. ............. ................ ............................ ....................... 199 Standard 2 of 5 Length C ontrol .
Product Referenc e Guide 7 Code 5 Hex to Decimal Conv ersion ............ ............................. ............................. ........................ ......... ............................. ........................ 233 Code 4 and Code 5 Common Configuration Item s .
8 QuickScan TM Lite QW2100 Appendix E. Keypad . ............................................................................... ............................. .. 297 Appendix F. Scancode Tables ........................................ .................
Product Reference Guide 1 Chapter 1 Introduc tion About this Guide This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programmi ng, maintenance and specifications.
Introduction 2 QuickScan TM Lite QW2100 ming bar codes necessary fo r configuring these features. Chapter 11, References provides details concerning programmable features. Appendix A, Technical Specifications lists physical and perfor mance characteristics, as well as environmental and regulatory specif ications.
Technical Support Product Reference Guide 3 T echnical Suppor t Datalogic W ebsite Support The Datalogic website ( www.scanning.datalo gic.com ) is the complete source for technical support and information for Datalogic products.
Introduction 4 QuickScan TM Lite QW2100 NO TES.
Product Reference Guide 5 Chapter 2 Getting Star ted About the Reader One distinctive feature offered by the reader is a very wide scan an gle which can read long linearbar codes, such as utlity bills.
Getting Started 6 QuickScan TM Lite QW2100 Setting Up the Reader Follow the steps provided in th is section to connect and get your reader up and commu- nicating with its host: 1. Install the Interf ace Cable 2. Select the Interf ace T ype 3. Configure Interf ace Settings (only if not using factor y settings for that interface) 4.
Setting Up the Reader Product Reference Guide 7 USB Connect ion — Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 2 . Keyboard Wedge Connectio n — The Keyboard Wedge cable has a ‘Y’ connection from the reader.
Getting Started 8 QuickScan TM Lite QW2100 Hands F ree Stand — c ontinued The holder cup can be positioned in any of the three angles shown in Figure 4 . Grasp the holder cup as indicated and rotate to the desired position. Refer to Scan Mode on page 30 for information about progr amming the reader for use with the stand.
Setting Up the Reader Product Reference Guide 9 U sing the Progr amming Bar C odes This manual contains feature descriptions and ba r codes which allow you to reconfigure your reader. Some programmin g bar code labels, like Resetting the Product Configura- tion to Defaults on page 10 , require only the scan of that single label to enact the change.
Getting Started 10 QuickScan TM Lite QW2100 Soft w are V ersion T ransmission The software version of the device can be transmitted over the RS-232 and Keyboard in- terfaces by scanning the following label.
Product Reference Guide 11 Chapter 3 In ter fac es Int er face Sele c tion Each reader model will support one of the following sets of host interfaces: USB Models ( all ar e 2.
Interfaces 12 QuickScan TM Lite QW2100 Table 1. Available Interfaces RS-232 FEA TURES RS-232 standard interface $P ,HA05,P Select RS232-STD Set RS-232 Interface F eatures star ting on page 37 $P ,.
Configuring the Interface Product Reference Guide 13 KEYBO ARD FEA TURES A T , PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard K ey Encoding $P ,HA29,P Select KBD-A T Set KEYBOARD.
Interfaces 14 QuickScan TM Lite QW2100 KEYBO ARD — cont. FEA TURES USB K eyboard with standard ke y encoding $P ,HA35,P Select USB Ke yboard Set KEYBOARD WEDGE Interface Fe atures star ting on p.
Global Interface Features Product Reference Guide 15 ENTER/EXIT PROGRAMMING MODE Global Inter face F eatures The following interface features ar e configurable by all interface types .
Interfaces 16 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE USB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode.
Product Reference Guide 17 Chapter 4 Gen er al F ea tur es Double Read T imeout T o prevent a double read of the same label, the Double Read T imeout sets the minimum time allowed between reads of labels of the same symbol ogy and data.
General Features 18 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Double Read Timeout — continued $CSNDR32 Double Read Timeout = 0.5 Second $CSNDR3C Double Read Timeout = 0.6 Second $CSNDR46 Double Read Timeout = 0.7 Second $CSNDR50 Double Read Timeout = 0.
Label Gone Timeout Product Reference Guide 19 ENTER/EXIT PROGRAMMING MODE Label Gone T imeout This feature sets the time after the last label s egment is seen before the reader pr epares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.
General Features 20 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Po we r S av e M o d e When this feature is enabled, the reader will enter Power Save Mode (a lower power consumption state) after being idle (no scanner activity) for one second.
Sleep Mode Timeout Product Reference Guide 21 ENTER/EXIT PROGRAMMING MODE Sleep Mode T i meout S pecifies th e timeout value for the r eader to en ter Sleep Mo de (a ver y lo w power consumption state). NO TE RS-232 interface ONL Y . A reader having a Scan Mode setting of Object Sense, Stand Mode, Flashing, or Always On will not enter Sleep Mode.
General Features 22 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE LED and Beeper Indicators Pow e r O n A l er t Disables or enable s the indication (from the Beepe r) that the reader is r eceiving power .
LED and Beeper Indicators Product Reference Guide 23 ENTER/EXIT PROGRAMMING MODE Go od Read : When to In dicate This feature specifies when the r eader will pro v ide indication (beep and/or flash its green LED) upon successfully reading a bar code.
General Features 24 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Good Read Beep T ype S pecifies whether the good read beep has a mono or bitonal beep sound.
LED and Beeper Indicators Product Reference Guide 25 ENTER/EXIT PROGRAMMING MODE Good Read Beep Fr equency Adjusts the good read beep to sound at a selectab le low , medium or high frequency , selectable from the list below . (Controls the beeper’ s pitch /tone.
General Features 26 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Good Read Beep Le ngth — continued $CBPLE08 Good Read Beep Length = 80 msec $CBPLE0A Good Read Beep Length = 100 msec.
LED and Beeper Indicators Product Reference Guide 27 ENTER/EXIT PROGRAMMING MODE Illumination C ontrol Controls illumination during a good r ead beep. NO TE Setting this configuration it em to turn off illumination during the beep reduces the peak current dra wn by the reader in some scanning modes.
General Features 28 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Good Read Beep V olume Selects the bee per volume (loudness) upon a good r ead beep.
LED and Beeper Indicators Product Reference Guide 29 ENTER/EXIT PROGRAMMING MODE Good Read LED Dur ation This feature specifies the amount of time that the Good Read LED remains on following a good read. The good r ead LED on time can be set wi thin a range of 0.
General Features 30 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Scanning F eatur es Scan Mod e See Scan Mode on page 2 46 for more detailed programming instructions.
Scanning Features Product Reference Guide 31 ENTER/EXIT PROGRAMMING MODE Stand Mode T riggered T imeout This feature specifies the time to remain in T rigger Single mode after the trigger is pulled while in Stand Mode . NO TE This timeout is only used when the Scan Mode is configured as Stand Mode .
General Features 32 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout — continued $CSNOT0C Stand Mode T riggered Timeout = 6 Seconds $CSNOT10 Stand Mode T rig.
Scanning Features Product Reference Guide 33 ENTER/EXIT PROGRAMMING MODE Scanning Active T ime This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second incr ements.
General Features 34 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Fla s h O n Tim e This feature specifies the ON time for the indi c ator LED while in Flash M ode. The select able range is 100 to 9,900 millisec onds (0.1 to 9.9 seconds), in 100 millisecond incr ements.
Scanning Features Product Reference Guide 35 ENTER/EXIT PROGRAMMING MODE Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices ar e low , medium and hi gh.
General Features 36 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Green Spot Dur ation S pecifies th e duration of the good r ead pointer beam after a good read.
Product Reference Guide 37 Chapter 5 RS -232 ONL Y Int er fac e Intr oduc tion U se the programming bar codes in this chapter if modifications to th e standard RS-232 inter- face settings are necessar y to meet your syst em ’ s requirements.
RS-232 ONLY Interface 38 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Baud Rate — continued $CR2BA03 Baud Rate = 9600 $CR2BA04 Baud Rate = 19,200 $CR2BA05 Baud Rate = 38,400 $CR2.
Data Bits Product Reference Guide 39 ENTER/EXIT PROGRAMMING MODE Data B its This parameter allows the reader to interface wi th devices re quiring a 7-bit or 8-bit ASCII pro- tocol for sending and receiving data.
RS-232 ONLY Interface 40 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Pa ri t y This feature specifies parity requir ed for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character . Select the parity type according to host device requirements.
Handshaking Control Product Reference Guide 41 ENTER/EXIT PROGRAMMING MODE Handshaking Control The data interface consists of an RS-232 por t designed to operate either with or without the hardware handshaking lines, R equest to Send (R TS), and Clear to S end (CTS).
RS-232 ONLY Interface 42 QuickScan TM Lite QW2100 NOTES.
Product Reference Guide 43 Chapter 6 RS -232/USB - C om Inter faces Intr oduc tion The programming bar codes in this chapter allow modifications to the standard RS-232 and USB-Com interface s. Standard F ac tor y Settings Refe renc e Appendix B, Standard Def aults for a list ing of standard factory settings.
RS-232/USB-Com Interfaces 44 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Inte rchar ac ter D elay This parameter specifies the intercharacter de lay between the end of one character and the beginning of the next. The delay can be set with in a range of zero (0) to 990 milliseconds in 10ms increments.
Beep On ASCII BEL Product Reference Guide 45 ENTER/EXIT PROGRAMMING MODE Beep On ASCII BEL When this parameter is en abled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.
RS-232/USB-Com Interfaces 46 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE AC K N A K O p t i o n s This enables/disables the ability of the read er to support the RS-2 32 A CK/NAK protocol. When configured, the reader and/or host sends an “ ACK” when it receiv es data properly , and sends “NAK” when the data is in error .
ACK NA K Options Product Reference Guide 47 ENTER/EXIT PROGRAMMING MODE A CK Character This setting specifies an ASCII character or hex value to be used as the ACK character . ASCII characters or any hex value from 0 to 0xFF can be selected. S ee A CK Character on page 251 for more detailed programming instructions.
RS-232/USB-Com Interfaces 48 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE AC K N A K Ti m e o u t V a l u e This option specifies the amount of time the re ader waits for an ACK character fr om the host following label transmission. The selectable time out range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments.
ACK NA K Options Product Reference Guide 49 ENTER/EXIT PROGRAMMING MODE AC K N A K Re t r y Co u n t This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries.
RS-232/USB-Com Interfaces 50 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE A CK NAK Error Handling This feature specifies the method the r eader uses to handle receive errors detected while waiting for an ACK character from the host.
Indicate Transmission Failure Product Reference Guide 51 ENTER/EXIT PROGRAMMING MODE Indicate T ransmission F ailure This option enables/disables the reader’ s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode. Disable Character S pecifies th e value of the RS-232 host command used to disable the r eader .
RS-232/USB-Com Interfaces 52 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Enable Character S pecifies th e value of the RS-232 host command used to enable the reader . ASCII characters or any hex value fr om 0 to 0xFF can be selected. S ee Enable Character on page 256 for more detailed programming instructions.
Product Reference Guide 53 Chapter 7 K eyboar d Int er fac e Intr oduc tion U se the programming bar codes in this chapter to select options for USB Keyboard and W edge Inte rfa ces . Standard F ac tor y Settings Refe renc e Appendix B, Standard Def aults for a list ing of standard factory settings.
Keyboard Interface 54 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Countr y Mode This feature specifies the country /language supported by the keyboard.
Country Mode Product Reference Guide 55 ENTER/EXIT PROGRAMMING MODE Country Mode — continued $CKBCO03 Countr y Mode = Denmark Suppor ts only the interf aces listed in the Country Mode feature description.
Keyboard Interface 56 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Country Mode — continued $CKBCO12 Country Mode = Poland Suppor ts only the interf aces listed in the Country Mode feature description. Suppor ts only the interf aces listed in the Countr y Mode f eature description.
Caps Lock State Product Reference Guide 57 ENTER/EXIT PROGRAMMING MODE Caps L ock State This option specifies the format in which the re ader sends character data . This applies to Key- board W edge interfaces. This does not app ly when an alternate key encoding keyboard is selected.
Keyboard Interface 58 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Key b o ar d Nu m er i c Key p a d This feature specifies if numeric characters will be sent using the standard keys or the numeric keypad .
Keyboard Send Control Characters Product Reference Guide 59 ENTER/EXIT PROGRAMMING MODE Keyboard Sen d Control Cha rac ters This feature is used by the Keyboard W edge and USB Keyboard interfaces. It specifies how the reader transmits ASCII control ch aracters to the host.
Keyboard Interface 60 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE We d g e Q u i e t I n t e r v a l This option specifies the amount of time to look for keyb oard activity before the reader breaks the keyboard conn ection in order to tr ansmit data to host.
Intercharacter Delay Product Reference Guide 61 ENTER/EXIT PROGRAMMING MODE Inte rchar ac ter D elay This parameter specifies the intercharacter de lay between the end of one character and the beginning of the next. The delay can be set within a range of ze ro (0) to 990 milliseconds in 10ms increments.
Keyboard Interface 62 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Inte rcode D elay S pecifies the delay between labels transmitted to th e host for this interface. The selectable range for this feature is from 0 to 99 seconds. S ee Intercode Dela y on page 259 for more d etailed programming instructions.
USB Keyboard Speed Product Reference Guide 63 ENTER/EXIT PROGRAMMING MODE USB K eyboard Speed This option specifies the USB poll rate for a USB Keyboard.
Keyboard Interface 64 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed — continued $CKBSP06 USB K eyboard Speed = 6ms $CKBSP07 USB K eyboard Speed = 7ms $CKBSP08 U.
Product Reference Guide 65 Chapter 8 USB - OEM In ter fac e Intr oduc tion F eature settings for USB interfaces differ depend ing upon which host type the r eader will be connected with. U se the feature settings in this chapter to specifically configure for the USB- OEM interface.
USB-OEM Interface 66 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE USB -OEM Devi ce U sage The USB-OEM protocol allows for the reader to be identified as one of two different types of bar code reade rs.
Product Reference Guide 67 Chapter 9 Data Editing Data Editing Ov er view When a bar code is scanned, additional inform ation can be sent to the host computer along with the bar code data. This combination of bar code data and supplementar y user-defined data is called a “ message string.
Data Editing 68 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Please Ke ep In Mind... • M odifying a message string is not a mandator y r equirement. Data editing is sophisticated feature allowing highly customizable output for advanced users.
Global AIM ID Product Reference Guide 69 ENTER/EXIT PROGRAMMING MODE Global AIM ID AIM label identifiers (as opposed to custom characte rs you select yourself as with label identifi- ers) can be included with scanned bar code data. See Global AIM ID on page 261 for mor e detailed programming instructions.
Data Editing 70 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Label ID A Label ID is a customizable code of up to th ree ASCII characters (each can be one of hex 0 x0 1 -0 x F F) , u se d t o i d e nt i fy a b a r c o d e ( s ym b o lo g y ) t y p e.
Label ID Product Reference Guide 71 ENTER/EXIT PROGRAMMING MODE Label ID: Set Individually P er Symbology This feature configures a Label ID individually for a single symbology . Label ID C ontrol This option controls whethe r a Label ID is disabled, or se nt as a prefix or suffix for a given sym- bology type.
Data Editing 72 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID S ymbology Selection This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Label ID Product Reference Guide 73 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID Symbology Se lection — continued This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Data Editing 74 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID Symbology Se lection — continued This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Label ID Product Reference Guide 75 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID Symbology Se lection — continued This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Data Editing 76 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID Symbology Se lection — continued This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Label ID Product Reference Guide 77 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID Symbology Se lection — continued This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Data Editing 78 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID Symbology Se lection — continued This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Label ID Product Reference Guide 79 ENTER/EXIT PROGRAMMING MODE Label ID — continued Label ID Symbology Se lection — continued This option selects the symbology for which a Label ID is to be configured. S ee Label ID: Set Individually P er Symbology on page 264 for full instructions.
Data Editing 80 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Set Global Mid Labe l ID Char ac ter(s) S pecifies a mid-label ID that is added for transm ission between the labels of a two label pair . The expected stri ng is a maximum of 20 charac ters.
Case Conversion Product Reference Guide 81 ENTER/EXIT PROGRAMMING MODE Case C onv ersion This feature allows conv ersion of the case of a ll alphabetic characters to upper or lower case. NO TE Case con version affects ONL Y scan ned bar code data, and does not affect Label ID , Prefix, Suffix, or other appended data.
Data Editing 82 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Character C onv ersion Character conversion is an eight byte configuration item. The eight b ytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted.
Product Reference Guide 83 Chapter 10 S ymbologies Intr oduc tion The reader supports the following symbologies (bar code types). Options for each symbology are included in this chapter . Sym b ol og i es Standard F ac tory S ettings f or Symbologies Default settings are indicated at each feature/option with a gr een arrow .
Symbologies 84 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Disable All S ymbologies Scan this label to disable all symbologies. Co up o n Co nt ro l This feature is used to control the method of processing coupon labels.
UPC-A Product Reference Guide 85 ENTER/EXIT PROGRAMMING MODE UPC-A The following options apply to the UPC-A symbology . UPC-A Enable/Disable When disabled, the reader will not read UPC-A bar codes. UPC-A Check Char ac ter T ransmission Enable this option to transmit the check character along wi th UPC-A bar code data.
Symbologies 86 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE UPC-A — cont. Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format.
UPC-A Product Reference Guide 87 ENTER/EXIT PROGRAMMING MODE UPC-A — cont. In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good r ead.
Symbologies 88 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE UPC-E The following options apply to the UPC-E symbology . UPC-E Enable/Disable When disabled, the reader will not read UPC-E bar codes. UPC-E Check Character T ransmission Enable this option to transmit the check character along with UPC-E bar code data.
UPC-E Product Reference Guide 89 ENTER/EXIT PROGRAMMING MODE UPC-E — cont. Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the sym- bology ID to match those required for EAN-13. Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
Symbologies 90 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE UPC-E — cont. UPC-E Number Sy stem Character T ransmission This feature enables/disables transmission of the UPC-E system number character .
EAN 13 Product Reference Guide 91 ENTER/EXIT PROGRAMMING MODE EAN 13 The following options apply to the EAN 13 (Jan 13) symbology . EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 bar codes. EAN 13 Check Character T ransmission Enable this option to transmit the check character along wi th EAN 13 bar code data.
Symbologies 92 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE EAN 13 — cont. EAN-13 Flag 1 Char acter Enables/disables transmission of an EAN/JAN13 Flag1 character .
EAN 13 Product Reference Guide 93 ENTER/EXIT PROGRAMMING MODE EAN 13 — cont. ISSN Enable/Disable Enables/disables conversion of EAN/JAN1 3 Bookland labels starting with 977 to ISSN label s. EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good r ead.
Symbologies 94 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE EAN 8 The following options apply to the EAN 8 ( J an 8) symbology . EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 bar codes. EAN 8 Check Character T ransmission Enable th is option to transmit th e check character along w ith EAN 8 bar code data.
EAN 8 Product Reference Guide 95 ENTER/EXIT PROGRAMMING MODE EAN 8 — cont. Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. EAN 8 Both Guards Substitution Enables/disables the ability of the reader to fi nd an EAN/JAN8 guard pattern in caseswhere the EAN/JAN8 margin makes the guard look like a character .
Symbologies 96 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE EAN 8 — cont. EAN 8 Guard Inser tion Enables/disables the ability to insert a guar d into an other wise fu ll-strike EAN 8 segment.
EAN 8 Product Reference Guide 97 ENTER/EXIT PROGRAMMING MODE EAN 8 — cont. EAN 8 Minimum S egment L ength Block S pecifies the m inimum number of characters necessary in an EA N/JAN8 label segment in order for the reader to accept the se gment for decoding.
Symbologies 98 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE EAN 8 — cont. EAN 8 Minimum Segment Length Block — cont. $C8BSB0B EAN 8 Minimum Segment Length Block = 11 $C8BSB0C EAN 8.
EAN 8 Product Reference Guide 99 ENTER/EXIT PROGRAMMING MODE EAN 8 — cont. EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read.
Symbologies 100 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE EAN 8 — cont. EAN 8 Stitch Exact Label Halves Enables/disables the abiliy to stitch exact EAN 8 label halves with no ov erlapping characters.
EAN Two Label Product Reference Guide 101 ENTER/EXIT PROGRAMMING MODE EAN T wo Label EAN T wo Label Enable/Disable When disabled, the reader will not read EAN two label bar codes. EAN T wo Label C ombined T ransmission This feature enables/disables transmission of an EAN two label pair as one label.
Symbologies 102 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE EAN T wo Label Minimum Reads This feature specifies the minimum number of consecutive times an EAN two label bar code must be decoded before it is accepted as good r ead.
UPC/EAN Global Settings Product Reference Guide 103 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbolo- gies, and affects all of these unless other w ise marked for each featur e description.
Symbologies 104 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings — cont. UPC/EAN C orrelation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the re ader read labels that have some spots and/or voids.
UPC/EAN Global Settings Product Reference Guide 105 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings — cont. UPC/EAN Pric e W eight Check This feature enables/disables calculation and verification of price/weight check digits.
Symbologies 106 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings — cont. UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as good r ead.
UPC/EAN Global Settings Product Reference Guide 107 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings — cont. UPC/EAN Guard Insertion Enables/disables the ability to insert either a mi ssing leading or trailing guard on an other wise complete UPC-A/EAN-13 segment.
Symbologies 108 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings — cont. UPC/EAN Stitch Unlik e Label Halves Enables/disables the ability to stitch two UPC- A/EAN 13 label halves together that may have differing characters in them.
UPC/EAN Global Settings Product Reference Guide 109 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings — cont. UPC/EAN Minimum Segment Length S pecifies the minimum number of characters ne cessar y in an UPC/EAN/JAN label segment in order for the re ader to accept the segment for decoding.
Symbologies 110 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE UPC/EAN Global Settings — cont. UPC/EAN Minimum Segment Length — cont. $CUNSL0B UPC/EAN Minimum Segment Length Block = 11 $.
Add-Ons Product Reference Guide 111 ENTER/EXIT PROGRAMMING MODE Add-Ons The following featur es apply to optional add-ons. Optional Add-ons The reader can be enabled to optionally re ad the following add-ons (supplementals): •P 2 •P 5 • GS1-128 NO TE Contact Customer Support for ad v anced programming of optional and conditional add-ons.
Symbologies 112 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Add-Ons — cont. Optional Add-ons — cont. $CADO501 Optional Add-Ons = Enable P5 $CADO800 Optional Add-Ons = Disable GS1-.
Add-Ons Product Reference Guide 113 ENTER/EXIT PROGRAMMING MODE Add-Ons — cont. Optional A dd- On T imer This option sets the time t he reader will look for an add-on when an add-on fragme nt has been seen and optional add-ons are enabled.
Symbologies 114 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Add-Ons — cont. Optional Add-On Timer — cont. $CADOT06 Optional Add-on Timer = 60ms $CADOT07 Optional Add-on Timer = 70.
Add-Ons Product Reference Guide 115 ENTER/EXIT PROGRAMMING MODE Add-Ons — cont. P2 Add-Ons Minimum Reads This feature specifies the minimum number of ti mes a P2 add-on must be r ead before it is marked as valid and then combined with a base labe l.
Symbologies 116 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Add-Ons — cont. P5 Add-Ons Minimum Reads This feature specifies the minimum number of ti mes a P5 add-on must be r ead before it is marked as valid and then combined with a base labe l.
Add-Ons Product Reference Guide 117 ENTER/EXIT PROGRAMMING MODE Add-Ons — cont. GS1-128 Add-Ons Minimum Reads Th i s f ea tu re sp e ci fi es t he mi ni m um nu m be r o f t im e s a n G S1 - 12 8 a dd - on mu st b e re a d b ef or e i t is marked as valid and then combined with a base labe l.
Symbologies 118 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE GS1 DataBar TM Omnidirec tional The following options apply to the GS1 DataB ar Omnidirectional (formerly RSS-14) symbol- ogy . GS1 DataBar Omnidir ec tional Enable/Disable Whe n dis abl ed, th e rea der w ill n ot rea d GS1 Data Bar Omni dire ctio nal b ar co des.
GS1 DataBar TM Omnidirectional Product Reference Guide 119 ENTER/EXIT PROGRAMMING MODE GS1 DataBarTM Omnidirectional — cont. GS1 DataBar Omnidir ec tional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirec- tional label must be decoded before it is accepted as good read .
Symbologies 120 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE GS1 DataBar TM Expanded The following options apply to the GS1 DataB a r Expanded (formerly RSS Expanded) symbol- ogy . GS1 DataBar Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar Expanded bar codes.
GS1 DataBar TM Expanded Product Reference Guide 121 ENTER/EXIT PROGRAMMING MODE GS1 DataBarTM Expanded — cont. GS1 DataBar Expand ed Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good r ead .
Symbologies 122 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE GS1 DataBarTM Expanded — cont. GS1 DataBar Expanded L ength Con trol This feature specifies either vari able length decoding or fixed le ngth decoding for the GS1 Data- Bar Expanded symbology .
GS1 DataBar TM Expanded Product Reference Guide 123 ENTER/EXIT PROGRAMMING MODE GS1 DataBarTM Expanded — cont. GS1 DataBar Expanded Set L ength 1 This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Con- trol .
Symbologies 124 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE GS1 DataBarTM Expanded — cont. GS1 DataBar Expanded Set L ength 2 This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Con- trol .
GS1 DataBar TM Limited Product Reference Guide 125 ENTER/EXIT PROGRAMMING MODE GS1 DataBar TM Limited The following options apply to the GS1 DataB ar Limited (formerly RSS Limited) symbology . GS1 DataBar Limited Enable/Disable When disabled, the reader will not read GS1 D ataBar Limited bar codes.
Symbologies 126 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE GS1 DataBarTM Limited — cont. GS1 DataBar Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read .
Code 39 Product Reference Guide 127 ENTER/EXIT PROGRAMMING MODE Co d e 3 9 The following options apply to the Code 39 symbology . C ode 39 Enable/Disable When disabled, the reader will not read Code 39 bar codes.
Symbologies 128 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Check Char ac ter Calculation Enable this option t o enable/disable calculation and verification of an optional Code 39 check character . When disabled, any check character in the label is treated as a data character.
Code 39 Product Reference Guide 129 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Check Char ac ter T ransmission Enable this option to transmit the check character along wi th Code 39 bar code data. Code 39 S tar t/Stop Char ac ter T ransmission Enable this option t o enable/d isable transmission of Code 39 start and stop characters.
Symbologies 130 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 F ull ASCII In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
Code 39 Product Reference Guide 131 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.
Symbologies 132 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. C ode 39 M inimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good r ead.
Code 39 Product Reference Guide 133 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Dec oding Lev el Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vative depend ing on a part icular custo mer’ s needs.
Symbologies 134 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Co de 39 Le n gt h Con tr ol This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology . Variable Length— F or variable length decoding, a minimum and maximum length may be set.
Code 39 Product Reference Guide 135 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Set L ength 1 This feature specifies one of the bar code lengths for Code 39 Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 136 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Set L ength 2 This feature specifies one of the bar code lengths for Code 39 Length Control . Length 2 is the maximum label length if in V ar iab le Length M ode, or the second fixed length if in Fix ed Length M ode.
Code 39 Product Reference Guide 137 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Inter digit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels.
Symbologies 138 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Interdigit Ratio — cont. $CC3IR06 Code 39 Interdigit Ratio = 6 $CC3IR07 Code 39 Interdigit Rati.
Code 39 Product Reference Guide 139 ENTER/EXIT PROGRAMMING MODE Code 39 — cont. Code 39 Character Correlation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the re ader read labels that have some spots and/or voids.
Symbologies 140 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE C ode 32 (Italian Pharmaceutical) The following options apply to the Code 32 symbology .
Code 32 (Italian Pharmaceutical) Product Reference Guide 141 ENTER/EXIT PROGRAMMING MODE Code 32 (Italian Pharmaceutical) — cont. Code 32 Check Char ac ter T ransmission Enable this option to transmit the check character along wi th Code 32 bar code data.
Symbologies 142 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE C ode 39 CIP (Frenc h Pharma ceutical) The following options apply to the Code 39 CIP symbology . C ode 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels.
Code 128 Product Reference Guide 143 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. E xp an d Co de 1 28 to Cod e 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels. When enabled, the label identifier for a Code 128 label shall be set to Code 39 and all Code 39 formatting con- trol shall be applied to the label.
Symbologies 144 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. Code 128 F unc tion Character T ransmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
Code 128 Product Reference Guide 145 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. Code 128 Quiet Z ones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones ar e blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.
Symbologies 146 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. C ode 128 M inimum Reads This feature specifies the minimum number of consecutive times a Code 12 8 label must be decoded before it is accepted as good r ead.
Code 128 Product Reference Guide 147 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. C ode 128 Decoding Lev el Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vative depend ing on a part icular custo mer’ s needs.
Symbologies 148 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. Co de 12 8 Le ng t h Co nt ro l This feature specifies either variable length deco ding or fixed length decoding for the Code 128 symbology . Variable Length— F or variable length decoding, a minimum and maximum length may be set.
Code 128 Product Reference Guide 149 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. Code 128 Set Length 1 This feature specifies one of the bar code lengths for Code 128 Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 150 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. Code 128 Set Length 2 This feature specifies one of the bar code lengths for Code 128 Length Control . Length 2 is the maximum label length if in V ar iab le Length Mode, or the second fix ed length if in Fixed Length M ode.
Code 128 Product Reference Guide 151 ENTER/EXIT PROGRAMMING MODE Code 128 — cont. Code 128 Ch aracter Correl ation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the re ader read labels that have some spots and/or voids.
Symbologies 152 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE GS1-128 The following options apply to the GS1-128 symbology . (Also known as USS-128, GTIN-128, UCC-128.) GS1-128 Enable This option enables/disables the ability of the re ader to translate GS1- 128 labels to the GS1-128 data format.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 153 ENTER/EXIT PROGRAMMING MODE Interleav ed 2 of 5 (I 2 of 5) The following options apply to the I 2 of 5 symbology . I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 bar codes.
Symbologies 154 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Calculation This option enables/disables calculation and verifi cation of an optional I 2 of 5 check character . When disabled, any check character in label is treated as a data character .
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 155 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Check Character Calculation — cont. I 2 of 5 Check Character T ransmission Enable this option to transmit the check character along wi th I 2 of 5 bar code data.
Symbologies 156 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label m ust be decoded before it is accepted as good r ead.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 157 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Decoding Le vel Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vative depend ing on a part icular custo mer’ s needs.
Symbologies 158 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Length C ontrol This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology . Variable Length— F or variable length decoding, a minimum and maximum length may be set.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 159 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for I 2 of 5 Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 160 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for I 2 of 5 Length Control . Length 2 is the maximum label length if in V ar iab le Length M ode, or the second fixed length if in Fix ed Length M ode.
Interleaved 2 of 5 (I 2 of 5) Product Reference Guide 161 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Character C orrelation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding.
Symbologies 162 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Interleaved 2 of 5 (I 2 of 5) — cont. I 2 of 5 Stitching This option enables/disables stitching for I 2 of 5 labels.
Datalogic 2 of 5 Product Reference Guide 163 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 The following options apply to the Datalogic 2 of 5 symbology . Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 bar codes.
Symbologies 164 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 — cont. Datalogic 2 of 5 Check Char ac ter C alculation This option enables/disables calculation and veri fication of an optional Datalogic 2 of 5 check character .
Datalogic 2 of 5 Product Reference Guide 165 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 — cont. Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of co nsecutiv e times an Datalogic 2 of 5 label must be decoded before it is accepted as good read.
Symbologies 166 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 — cont. Datalogic 2 of 5 L ength Contr ol This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology . Variable Length— F or variable length decoding, a minimum and maximum length may be set.
Datalogic 2 of 5 Product Reference Guide 167 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control . Length 1 is the minimum label length if in V ariable Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 168 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 — cont. Datalogic 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control . Length 2 is the maximum label length if in V ariable Length M ode, or the second fixed length if in Fix ed Length M ode.
Datalogic 2 of 5 Product Reference Guide 169 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Int erdigit Maximum Ratio This feature specifies the maximum ratio betwee n intercharacter space and module for Data- logic 2 of 5.
Symbologies 170 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Interdig it Maximum Ratio — cont. $CD2IR06 Datalogic 2 of 5 Interdigit Maximum Ratio = 6 $CD2IR07 Datalo.
Datalogic 2 of 5 Product Reference Guide 171 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 — cont. Datalogic 2 of 5 Char acter Corr elation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the re ader read labels that have some spots and/or voids.
Symbologies 172 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Co d ab a r The following options apply to the Codabar symbology . Co da b ar En a bl e/ D is a bl e When disabled, the reader will not read Codabar bar codes.
Codabar Product Reference Guide 173 ENTER/EXIT PROGRAMMING MODE Codabar — cont. Codabar Check Char ac ter T ransmission Enable this option to transmit the check character along wi th Codabar bar code data. C odabar Star t/Stop Ch aracter T ransmission Enable this option t o enable /disable transmission of Codabar start and stop characters.
Symbologies 174 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Codabar — cont. Codabar St ar t/Stop Ch aracte r Set This option specifies the format of tr ansmitted Codabar start/stop charact ers .
Codabar Product Reference Guide 175 ENTER/EXIT PROGRAMMING MODE Codabar — cont. C odabar Star t/Stop Ch aracter Match When enabled, this option requir es that start and stop characters match.
Symbologies 176 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Codabar — cont. Co da b ar Q ui et Zo n es This feature specifies the number of quiet zone s for Codabar labels. Quiet zones ar e blank areas at the ends of a bar code and are typically 10 ti mes the width of the narrowest bar or space in the label.
Codabar Product Reference Guide 177 ENTER/EXIT PROGRAMMING MODE Codabar — cont. C odabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good r ead.
Symbologies 178 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Codabar — cont. C odabar Decoding Lev el Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vativ e depending on a particular customer’ s needs.
Codabar Product Reference Guide 179 ENTER/EXIT PROGRAMMING MODE Codabar — cont. Co da b ar Le ng th Co nt ro l This feature specifies either variable length de coding or fix ed length decoding for the Codabar symbology . Variable Length— F or variable length decoding, a minimum and maximum length may be set.
Symbologies 180 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Codabar — cont. C odabar Set Length 1 This feature specifies one of the bar code lengths for Codabar Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Codabar Product Reference Guide 181 ENTER/EXIT PROGRAMMING MODE Codabar — cont. C odabar Set Length 2 This feature specifies one of the bar code lengths for Codabar Length Control . Length 2 is the maximum label length if in V ar iab le Length Mode, or the second fix ed length if in Fixed Length M ode.
Symbologies 182 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Codabar — cont. Co da b ar In te rd ig i t R a ti o This feature specifies the ratio between an intercharacter space and module for Codabar labels.
Codabar Product Reference Guide 183 ENTER/EXIT PROGRAMMING MODE Codabar — cont. Codabar Interdigit Ratio — cont. $CCBIR06 Codabar Interdigit Ratio = 6 $CCBIR07 Codabar Interdigit Ratio = 7.
Symbologies 184 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Codabar — cont. Codabar Char ac ter C orrelation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the re ader read labels that have some spots and/or voids.
ABC Codabar Product Reference Guide 185 ENTER/EXIT PROGRAMMING MODE ABC C odabar The following options apply to the ABC Co dabar symbology . ABC C odabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. AB C Co da ba r Con c at en at i on M od e S pecifies the concatenation mode between Static and Dynamic.
Symbologies 186 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE ABC Codabar — cont. ABC C odabar D ynamic C oncatenation T imeout S pecifies th e timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatena- tion Mode.
Code 11 Product Reference Guide 187 ENTER/EXIT PROGRAMMING MODE ABC Codabar — cont. AB C Co da ba r Forc e Co n ca te na ti o n F orces labels starting or ending with D to be concatenated. Co d e 1 1 The following options apply to the Code 11 symbology .
Symbologies 188 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. Code 11 Check Char ac ter Calculation This option enables/disables calculation and ve rification of optional Code 11 c heck character . Code 11 Check Char ac ter T ransmission This feature enables/disables transmission of an optional Code 11 check character .
Code 11 Product Reference Guide 189 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. C ode 11 M inimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good r ead.
Symbologies 190 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. Co de 11 Le n gt h Con tr ol This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology . Variable Length— F or variable length decoding, a minimum and maximum length may be set.
Code 11 Product Reference Guide 191 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. Code 11 Set L ength 1 This feature specifies one of the bar code lengths for Code 11 Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 192 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. Code 11 Set L ength 2 This feature specifies one of the bar code lengths for Code 11 Length Control . Length 2 is the maximum label length if in V ar iab le Length M ode, or the second fixed length if in Fix ed Length M ode.
Code 11 Product Reference Guide 193 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. Code 11 Inter digit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels.
Symbologies 194 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. Code 11 Interdigit Ratio — cont. $CC1IR06 Code 11 Interdigit Ratio = 6 $CC1IR07 Code 11 Interdigit Rati.
Code 11 Product Reference Guide 195 ENTER/EXIT PROGRAMMING MODE Code 11 Dec oding Lev el Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vative depend ing on a part icular custo mer’ s needs. See Decoding Lev els on page 267 for more detailed programming instructions.
Symbologies 196 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 11 — cont. Code 11 Character Correlation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the re ader read labels that have some spots and/or voids.
Standard 2 of 5 Product Reference Guide 197 ENTER/EXIT PROGRAMMING MODE Stan dard 2 of 5 The following options apply to the S tandard 2 of 5 symbology . Standard 2 of 5 Enable/Disabl e When disabled, the reader will not read S tandard 2 of 5 bar codes.
Symbologies 198 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 — cont. Standard 2 of 5 Check Char ac ter T ransmission This feature enables/disables transmission of an optional S tandard 2 of 5 check character .
Standard 2 of 5 Product Reference Guide 199 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 — cont. Standard 2 of 5 Dec oding Lev el Stan dard 2 of 5 Leng th Contro l This feature specifies either variable length deco ding or fixed length decoding for the Standar d 2 of 5 symbology .
Symbologies 200 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 — cont. Standard 2 of 5 Set L ength 1 This feature specifies one of the bar code len gths for Standard 2 of 5 Length Control . Length 1 is the minimum label length if in V ariable Length M ode, or the first fixed length if in Fix ed Length M ode.
Standard 2 of 5 Product Reference Guide 201 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 — cont. Standard 2 of 5 Set L ength 2 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control . Length 2 is the maximum label length if in V ar iab le Length Mo de, or the second fixed length if in Fix ed Length M ode.
Symbologies 202 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 — cont. Standard 2 of 5 Char acter Corr elation When correlation is enabled, the bar code reader will combine label data from multiple scans when decoding. Enabling correlation will help the re ader read labels that have some spots and/or voids.
Industrial 2 of 5 Product Reference Guide 203 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 The following options apply to the I ndustrial 2 of 5 symbology . Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode I ndustrial 2 of 5 labels.
Symbologies 204 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 — cont. Industrial 2 of 5 Check Char ac ter T ransmission Enables/disables transmission of an Industrial 2 of 5 check character .
Industrial 2 of 5 Product Reference Guide 205 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 — cont. Industrial 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Contro l . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 206 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 — cont. Industrial 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control . Length 2 is the maximum label length if in V ar iab le Length Mo de, or the second fixed length if in Fix ed Length M ode.
Industrial 2 of 5 Product Reference Guide 207 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 — cont. Industrial 2 of 5 Minimum Reads This feature specifies the minimum number of cons ecutive times an Industrial 2 of 5 label m ust be decoded before it is accepted as good read.
Symbologies 208 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 — cont. Industrial 2 of 5 Stitching Enables/disables fixed length stitching for Industrial 2 of 5. Industrial 2 of 5 Character C orrelation Enable/disables character correl ation for Industrial 2 of 5.
IATA Product Reference Guide 209 ENTER/EXIT PROGRAMMING MODE IA T A The following options apply to the IA T A symbology . IA T A Enable/Disable Enables/Disables the ability of th e reader to decode IA T A labels. IA T A Check Character T ransmission Enables/Disables calculation and verification of an optional I ndustrial 2 of 5 check character .
Symbologies 210 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE ISB T 128 The following options apply to the ISBT 128 symbology . ISB T 128 Conca tenation Enables/disables ISBT128 concatenation of 2 labels. ISB T 128 Conca tenation Mode S pecifies the concatenation mode between Static and Dynamic.
ISBT 128 Product Reference Guide 211 ENTER/EXIT PROGRAMMING MODE ISBT 128 — cont. ISB T 128 Dy namic C oncatena tion Timeout S pecifies th e timeout used by the ISBT 128 Dynamic Concatenation Mode.
Symbologies 212 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE ISBT 128 — cont. ISB T 128 Fo rce C oncat enation When enabled, this feature forces all ISBT 128 labels to be concatenated. ISB T 128 Advanc ed Conca tenation Options NO TE This option is only valid when ISBT 128 Concatenation is enabled.
MSI Product Reference Guide 213 ENTER/EXIT PROGRAMMING MODE MSI The following options apply to the MSI symbology . MSI Enable/Disable Enables/Disables ability of re ader to decode MSI labels. MSI Check Character Calcul ation Enables/Disables calculation and verificati on of an optional MSI check character .
Symbologies 214 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE MSI — cont. MSI Check Character T ransmission Enables/disables transmission of an MSI check character . MSI Length C ontrol This feature specifies either variable length de coding or fix ed length decoding for the MSI sym- bology .
MSI Product Reference Guide 215 ENTER/EXIT PROGRAMMING MODE MSI — cont. MSI Set Length 1 This feature specifies one of the bar code lengths for MSI Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 216 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE MSI — cont. MSI Set Length 2 This feature specifies one of the bar code lengths for MSI Length Control . Length 2 is the maximum label length if in V ar iab le Length M ode, or the second fixed length if in Fix ed Length M ode.
MSI Product Reference Guide 217 ENTER/EXIT PROGRAMMING MODE MSI — cont. MSI Mi nimum Reads This feature specifies the minimu m number of consecutive times an MSI label must be decoded before it is accept ed as good read.
Symbologies 218 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE MSI — cont. MSI Decoding Lev el Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vativ e depending on a particular customer’ s needs.
Code 93 Product Reference Guide 219 ENTER/EXIT PROGRAMMING MODE Co d e 9 3 The following options apply to the Code 93 symbology . C ode 93 Enable/Disable Enables/Disables ability of reader to decode Code 93 labels. Code 93 Check Char ac ter Calculation Enables/disables calculation and verification of an optional Code 93 chec k character .
Symbologies 220 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 93 — cont. Code 93 Check Char ac ter T ransmission Enables/disables transmission of an optional Code 93 check character . Co de 93 Le n gt h Con tr ol This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology .
Code 93 Product Reference Guide 221 ENTER/EXIT PROGRAMMING MODE Code 93 — cont. Code 93 Set L ength 1 This feature specifies one of the bar code lengths for Code 93 Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 222 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 93 — cont. Code 93 Set L ength 2 This feature specifies one of the bar code lengths for Code 93 Length Control . Length 2 is the maximum label length if in V ar iab le Length M ode, or the second fixed length if in Fix ed Length M ode.
Code 93 Product Reference Guide 223 ENTER/EXIT PROGRAMMING MODE Code 93 — cont. C ode 93 M inimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good r ead.
Symbologies 224 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 93 — cont. Code 93 Dec oding Lev el Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vativ e depending on a particular customer’ s needs.
Code 93 Product Reference Guide 225 ENTER/EXIT PROGRAMMING MODE Code 93 — cont. Code 93 Quiet Zones Enables/disables fixed length stitching for Code 93.
Symbologies 226 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 93 — cont. C ode 93 Stitching Disable/enable fixe d or variable length stitching for Cod e 93. Code 93 Character Correlation Enables/disables Character Correlation for Code 93.
Codablock F Product Reference Guide 227 ENTER/EXIT PROGRAMMING MODE C odablock F The following options apply to the Codablock F symbology . Codablock F Enable/Disable Enables/Disables the ability of the reader to decode Codablock F labels.
Symbologies 228 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Co da b lo c k F AI M Ch ec k S pecifies if Check Digit calculation algorithm is AIM compliant or not. Co da b lo c k F Le ng t h Co nt ro l This feature specifies either vari able length decoding or fixed length decoding for the Codablock F symbology .
Codablock F Product Reference Guide 229 ENTER/EXIT PROGRAMMING MODE Codablock F — cont. Codablock F Set Length 1 This feature specifies one of the bar code lengths for Codablock F Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 230 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Codablock F — cont. Codablock F Set L ength 2 This feature specifies one of the bar code lengths for Codablock F Length Control . Length 2 is the maximum label length if in V ar iab le Length M ode, or the second fixed length if in Fix ed Length M ode.
Code 4 Product Reference Guide 231 ENTER/EXIT PROGRAMMING MODE Co d e 4 The following options apply to the Code 4 symbology . C ode 4 Enable/Disable Enables/Disables ability of reader to decode Code 4 labels. C ode 4 Check Character T ransmission This feature enables/disables transmission of an optional Code 4 check character .
Symbologies 232 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Code 4 — cont. Code 4 He x to Decimal Con version This feature enables/disables the conversion of hexidecimal label data to decimal label data. Co d e 5 The following options apply to the Code 5 symbology .
Code 5 Product Reference Guide 233 ENTER/EXIT PROGRAMMING MODE Code 5 — cont. C ode 5 Check Character T ransmission This feature enables/disables transmission of an optional Code 5 check character . Code 5 He x to Decimal Con version This feature enables/disables the conversion of hexidecimal label data to decimal label data.
Symbologies 234 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE Co d e 4 a n d Cod e 5 Co mm o n Co nf i g u ra ti o n I t e ms The following options apply to both Code 4 and Code 5 symbologies.
Code 4 and Code 5 Common Configuration Items Product Reference Guide 235 ENTER/EXIT PROGRAMMING MODE Code 4 and Code 5 Common Co nfiguration Items — cont. C ode 4 and Code 5 Minimum Reads This feature specifies the minimum number of co nsecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read.
Symbologies 236 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE F ollett 2 of 5 The following options apply to the F ollett 2 of 5 symbology . F ollett 2 of 5 Enable/Disable Enables/Disables ability of reader to decode F ollett 2 of 5 labels. BC412 The following options apply to the BC412 symbology .
BC412 Product Reference Guide 237 ENTER/EXIT PROGRAMMING MODE BC412 — cont. BC412 Check Character Calcula tion Enable this option t o enable/disable calculation and verification of an optional BC412 check character . When disabled, any check character in the label is treated as a data character.
Symbologies 238 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE BC412 — cont. BC412 Minimum Reads This feature specifies the minimum number of consecutive times a BC41 2 label must be decoded before it is accepted as good r ead.
BC412 Product Reference Guide 239 ENTER/EXIT PROGRAMMING MODE BC412 — cont. BC412 Dec oding Lev el Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vative depend ing on a part icular custo mer’ s needs.
Symbologies 240 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE BC412 — cont. BC412 Length C ontrol This feature specifies either variable length de coding or fix ed length decoding for the BC412 symbology . Variable Length— F or variable length decoding, a minimum and maximum length may be set.
BC412 Product Reference Guide 241 ENTER/EXIT PROGRAMMING MODE BC412 — cont. BC412 Set Length 1 This feature specifies one of the bar code lengths for BC412 Length Control . Length 1 is the minimum label length if in V ar iab le Length M ode, or the first fixed length if in Fix ed Length M ode.
Symbologies 242 QuickScan TM Lite QW2100 ENTER/EXIT PROGRAMMING MODE BC412 — cont. BC412 Set Length 2 This feature specifies one of the bar code lengths for BC412 Length Control . Length 2 is the maximum label length if in V ar iab le Length M ode, or the second fixed length if in Fix ed Length M ode.
Product Reference Guide 243 Chapter 11 Refer enc es This section contains explanations and examples of selec ted bar code features. S ee the program- ming sections for the actual bar code labels used to configure the reader .
References 244 QuickScan TM Lite QW2100 Label Gone T imeout This feature sets the time after the last label s egment is seen before the reader pr epares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.
Good Read LED Duration Product Reference Guide 245 Good Read LED Dura tion This feature specifies the amount of time that the Good Read LED remains on follo wing a good read. The good r ead LED on time can be set wi thin a range of 0.1 to 25.5 seconds in 100ms increments.
References 246 QuickScan TM Lite QW2100 Scan Mod e Selects the scan operating mode for the r eader . Selections are: Trigger Single— When the trigger is pulled, scanning is activated until one of th.
Scanning Active Time Product Reference Guide 247 Scanning Active T ime This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second incr ements.
References 248 QuickScan TM Lite QW2100 Fl as h O n Ti me This feature specifies the ON time for the indi c ator LED while in Flash M ode. The select able range is 100 to 9,900 millisec onds (0.1 to 9.9 seconds), in 100 millisecond incr ements. F ollow these instructions to set this feature.
Flash Off Time Product Reference Guide 249 Fl as h O f f Ti me This feature specifies the OFF time for the indicator LED while in F lash M ode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond incre ments. F ollow these instructions to set this feature.
References 250 QuickScan TM Lite QW2100 Inte rchar ac ter D elay This parameter specifies the intercharacter de lay between the end of one character and the beginning of the next. The delay can be set with in a range of zero (0) to 990 milliseconds in 10ms increments.
ACK Character Product Reference Guide 251 A CK Character This setting specifies an ASCII character or hex value to be used as the ACK character . ASCII characters or any hex value from 0 to 0xFF can be selected. T o set this feature: 1. Determine the desire d character or value.
References 252 QuickScan TM Lite QW2100 NAK Charac ter This setting specifies an ASCII character or hex value to be used as the NAK character . ASCII characters or any hex value from 0 to 0xFF can be selected. T o set this feature: 1. Determine the desire d character or value.
ACK NAK Timeout Value Product Reference Guide 253 AC K N A K Ti m e o u t V a l u e This option specifies the amount of time the re ader waits for an ACK character fr om the host following label transmission. The selectable time out range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments.
References 254 QuickScan TM Lite QW2100 A CK NAK Retry Coun t This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
Disable Character Product Reference Guide 255 Disable Character S pecifies th e value of the RS-232 host command used to disable the r eader . ASCII characters or any hex value from 0 to 0xFF can be selected. T o set the value: 1. Determine the desired character or value.
References 256 QuickScan TM Lite QW2100 Enable Character S pecifies th e value of the RS-232 host command used to enable the reader . ASCII characters or any hex value from 0 to 0xFF can be selected. T o set this feature: Determine the desired character or value.
Wedge Quiet Interval Product Reference Guide 257 We d g e Q u i e t I n t e r v a l This option specifies the amount of time to lo ok for keyboard activity before the reader breaks the keyboard conn ection in order to tr ansmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments.
References 258 QuickScan TM Lite QW2100 Inte rchar ac ter D elay This parameter specifies the intercharacter de lay be tween the end of one c haracter and the beginning of the next. The delay can be set within a range of ze ro (0) to 990 milliseconds in 10ms increments.
Intercode Delay Product Reference Guide 259 Inte rcode D elay S pecifies the delay between labels transmitted to th e host for this interface. The selectable range for this feature is from 0 to 99 seconds. F ollow these instructions to set this feature: 1.
References 260 QuickScan TM Lite QW2100 Global Pr efix/Suffix U p to 20 ASCII characters may be added as a pref ix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data) as indicated in Figure 7 . Figure 7.
Global AIM ID Product Reference Guide 261 Global AIM ID AIM label identifiers (as opposed to custom characte rs you select yourself as with label identifi- ers) can be included with scanned bar c ode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), follo wed by .
References 262 QuickScan TM Lite QW2100 Label ID: Pr e -loaded Sets The following table lists the pre-loaded label ID sets for the USA and E urope. Table 17.
Label ID: Pre-loa ded Sets Product Reference Guide 263 IA T A IA 494100 & 260000 Industrial 2 of 5 W 570000 W 570000 Interleav ed 2 of 5 CIP HR e 650000 e 650000 ISBN I 490000 @ 400000 ISBT128 f 6.
References 264 QuickScan TM Lite QW2100 Label ID: Set Individually P er Symbology T o configure a Label ID individually for a single symbology: 1. Scan the ENTER/EXIT bar code.
Label ID: Set Individually Per Symbology Product Reference Guide 265 Label ID: Set Individually Per Symbology — continued Table 18. Label ID Exam ples STEP A CTION EXAMPLES 1.
References 266 QuickScan TM Lite QW2100 Character C onv ersion Character conversion is an eight byte configuration item. The eight b ytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted.
Decoding Levels Product Reference Guide 267 Decoding L evels Decoding Levels are used to configure a bar code symbology decoder to be ver y aggressive to very conser vative dependin g on a particu lar customer’ s needs.
References 268 QuickScan TM Lite QW2100 Set Length 1 This feature specifies one of the bar code length s for a given symbology . Length 1 is the mini- mum label length if in V arible Length Mode, or the first fixed length if in F ixed Length Mode. Length includes the bar code ’ s data characters only .
Set Length 2 Product Reference Guide 269 Set Length 2 This feature specifies one of the bar code length s for a given symbology . Length 2 is the maxi- mum label length if in V ariable Length Mode, or the second fixed length if in F ixed Length M ode.
References 270 QuickScan TM Lite QW2100 NOTES.
Product Reference Guide 271 Appendix A T echnical Specifications Table 1 contains Physical and Performance Char acteristics, User Environment and Reg- ulatory information. Table 2 provides Standard Cable Pinouts. T able 1. T echnical Specification s Item Description Physical Characteristics Dimensions 2.
272 QuickScan TM Lite QW2100 Decode Capability UPC/EAN/JAN, P2 /P5 GS1-128 add-ons; Code 39; Code 39 Full ASCII; Code 32 (Italian Pharmacode); Code 128; ISBT 128; I 2 of 5; Standard 2 of 5; Code 11; C.
Standard Cable Pinouts Product Reference Guide 273 Standard C able Pinouts Figure 10 and Table 2 provide standard pinout info rmation for the reader’s cable. Fig u re 1 0. St a nd ar d Ca b le Pi no ut s The signal descriptions in Table 2 apply to the connector on the reader and are for ref- erence only.
274 QuickScan TM Lite QW2100 NO TES.
Product Reference Guide 275 Appendix B Standar d Defaults The most common configuration settings are listed in the “Default” column of Table 3 . The settings in this tabl e are as applied to a stan dard RS-232 interface. See Table 4 for a listing of default exceptions to this list as appled to other in te rface types.
276 QuickScan TM Lite QW2100 Scanning Activ e Time 5 Seconds 33 Stand Mode Flash Disab le 33 Flash On Time 1 Second 34 Flash Off Time 600 ms 34 Stand Mode Sensitivity Medium 35 Green Spot Duration 300.
Product Reference Guide 277 K eyboard Send Control Characters Disab le 59 We dge Quiet Inter val 100ms 60 Intercharacter Dela y No Dela y 61 Intercode Dela y 100 ms 62 USB K eyboard Speed 1 ms 63 USB-.
278 QuickScan TM Lite QW2100 Expand UPC-E to UPC-A Don’t Expand 89 UPC-E Number System Char acter T rans- mission Tr a n s m i t 90 UPC-E Minimum Reads 2 90 EAN 13 EAN 13 Enab le/Disable Enable 91 E.
Product Reference Guide 279 UPC-A Minimum Reads 1 Read 106 UPC/EAN Guard Inser tion Disab le 107 UPC/EAN Stitch Exact Label Halves Disab le 107 UPC/EAN Stitch Un like Label Halv es Disab le 108 UPC/EA.
280 QuickScan TM Lite QW2100 Code 39 Code 39 Enab le/Disable Enable 127 Code 39 Chec k Character Calculatio n Calculate 128 Code 39 Chec k Character T ransmission Send 129 Code 39 Start/Stop Character.
Product Reference Guide 281 Code 128 Leng th Control Va r i a b l e 148 Code 128 Set Length 1 1 149 Code 128 Set Length 2 80 150 Code 128 Character Co rrelation Disab le 151 Code 128 Stitching Enable .
282 QuickScan TM Lite QW2100 Datalogic 2 of 5 Inte rdigit Maximum Ratio 4 169 Datalogic 2 of 5 Character Correlation Disab le 171 Datalogic 2 of 5 Stitching Disab le 171 Codabar Codabar Enab le/Disabl.
Product Reference Guide 283 Code 11 Length Control Va r i a b l e 190 Code 11 Set Length 1 4 191 Code 11 Set Length 2 50 192 Code 11 Interdigit Ratio 4 193 Code 11 Decoding Le vel 3 195 Code 11 Charac.
284 QuickScan TM Lite QW2100 Industri al 2 of 5 Character Correla tion Disab le 208 IA T A IA T A Enable/Disable Disab le 209 IA T A Check Character T ransmission Enable 209 ISBT 128 ISBT 128 Concaten.
Product Reference Guide 285 Code 93 Quiet Zones Aut o 225 Code 93 Stitching Enable 226 Code 93 Character Correlation Enable 226 Codabloc k F Codab lock F Enab le/Disable Disab le 227 Codab lock F EAN .
286 QuickScan TM Lite QW2100 Default Ex ceptions Table 3 lists standard defa ult settings as ap plied to a standard RS-232 interface. Table 4 provides a listing of de fault exceptions to that list as applied to the o ther interface types.
Default Exceptions Product Reference Guide 287 Datalogic 2 of 5 Label ID Character(s) H ISBT 128 Label ID Character(s) K UPCE P2 Label ID Character(s) C UPCE/P5 Label ID Character(s) C UPCE/GS1-128 La.
288 QuickScan TM Lite QW2100 GS1-128 Label ID Character(s) k UPCA/P2 Label ID Character(s) F UPCA/P5 Label ID Character(s) G UPCA/GS1-128 Label ID Character(s) Q UPCE P2 Label ID Character(s) H UPCE/P.
Product Reference Guide 289 Appendix C LED and Beeper Indications The reader’s beeper sounds and its LED illumin ates to indicate vari ous functions or er- rors on the reader. An option al “Green Spot” also performs useful functions . The tables below list these indications.
290 QuickScan TM Lite QW2100 LED and Beeper Indications INDICA TION DESCRIPTION LED BEEPER P ower-up Beep The reader is in the process of pow- ering-up. Reader beeps four time s at highest frequency and v olume upon power- up . Good Read Beep A label has been successfully scanned by the reade r .
Error Codes Product Reference Guide 291 Error C o des Upon startup, if the reader sounds a long to ne, this means the reader has not passed its automatic Selftest and has entered FRU 1 isolation mode. If the reader is reset, the se- quence will be repeated.
292 QuickScan TM Lite QW2100 NO TES.
Product Reference Guide 293 A ppendix D Sample Bar C odes The sample bar codes in this appendix are typic al representations for their symbology types.
294 QuickScan TM Lite QW2100 Sample Bar Codes — continued Code 32 Codabar Code 93 Code 11.
GS1 DataBar (RSS) Product Reference Guide 295 GS1 DataBar (RSS) GS1 DataBar-14 NO TE GS1 DataBar vari ants must be enable d to read the bar codes below (see GS1 DataBar (RSS) on page 295 ).
296 QuickScan TM Lite QW2100 NO TES.
Product Reference Guide 297 Appendix E Key p a d Use the bar codes in this appendix to enter numbers as you would se lect digits/characters from a keypad.
298 QuickScan TM Lite QW2100 6 7 8 9 A B C.
Product Reference Guide 299 D E F.
300 QuickScan TM Lite QW2100 NO TES.
Product Reference Guide 301 Appendix F Scanc ode T ables C ontrol Char ac ter Emula tion Control character emulation selects from differ ent scancode tables as listed in this appendix. Each of the control character sets below ar e detailed by interface type in the tables.
Product Referenc e Guide 302 Inter face T ype PC A T PS/2 or USB -K eyboard Table 1. Scancode Set When Contr ol Character is 00 or 01 Extended characters (sky b lue) are sent vi a dedicated keys (when a vailab le in the selected countr y mode) or b y an Alt Mode sequ ence.
Product Referenc e Guide 303 Interface Type PC AT PS/2 or USB-Keyboard — cont. Table 2. Scancode Set When C ontrol Character is 02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al.
Product Referenc e Guide 304 Inter face type PC A T PS/ 2 Alt Mode or USB-K eyboard Alt Mode Table 3. Scancode Set When Contr ol Character is 00 or 01 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE Xf 0.
Product Referenc e Guide 305 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — co nt. Table 4. Scancode Set When C ontrol Character is 02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF .
Product Referenc e Guide 306 Digital Inter fac e Table 5. Scancode Set When Contr ol Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x NULL C(S)+@ SOH C(S)+A STX C(S)+B ETX C(S).
Product Referenc e Guide 307 Digital Interface — cont. Table 6. Scancode Set When C ontrol Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl Cl BS Ta b S+ T ab Enter Keypd Enter Ins 1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space ! “ # $ % & ‘ ( ) * + , - .
Product Referenc e Guide 308 IBM XT Table 7. Scancode Set When Contr ol Character is 00 or 01 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x NULL C(S)+@ SOH C(S)+A STX C(S)+B ETX C(S)+C EOT C+D EN.
Product Referenc e Guide 309 IBM XT — cont. Table 8. Scancode Set When C ontrol Character is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr.
310 QuickScan TM Lite QW2100 Microsoft W indow s C odepage 1252 Windows-1252 is a character encoding of the Lati n alphabet, used by default in the legacy com- ponents of Microsoft W indows in Engl ish and some other W estern languages.
Product Reference Guide 311 Inde x B bar codes RS-232 baud rate 63 RS-232 parameters parity 231 , 232 , 234 , 236 barcodes cancel 297 numeric barcodes 297 RS-232 parameters parity 56 Beeper Pitch, Goo.
312 QuickScan TM Lite QW2100 Print Contrast Minimum 271 Product Specifications 271 Programming Barcodes 9 R Read, Beeper – Good 22 Read, Beeper Pitch – Good 24 , 25 Read, Beeper Volume – Good 28.
ASCII Chart ASCII Char . Hex No . ASCII Char . Hex No . ASCII Char . Hex No . ASCII Char . He x No . NUL SOH STX ETX EO T ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB.
Austr alia Datalogic Scanning Pty Ltd T elephone: [61] (2) 9870 3200 australia.scanning@datalogic .com Fra n ce a n d B e ne l u x Datalogic Scanning SAS T elephone: [33].01.64.86.71.00 france .scanning @datalogic.com Germ an y Datalogic Scanning GmbH T elephone: 49 (0) 61 51/93 58-0 germany .
An important point after buying a device Datalogic QuickScan Lite QW2100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Datalogic QuickScan Lite QW2100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Datalogic QuickScan Lite QW2100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Datalogic QuickScan Lite QW2100 you will learn all the available features of the product, as well as information on its operation. The information that you get Datalogic QuickScan Lite QW2100 will certainly help you make a decision on the purchase.
If you already are a holder of Datalogic QuickScan Lite QW2100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Datalogic QuickScan Lite QW2100.
However, one of the most important roles played by the user manual is to help in solving problems with Datalogic QuickScan Lite QW2100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Datalogic QuickScan Lite QW2100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center